Purpose: The purpose of this study was to investigate the effect of whole body vibration in oxygen uptake during intense squatting exercise with an added weight and whole body vibration compared with the same exercise without vibration. Methods: Nine male subjects performed three trials of dynamic squatting with an additional load of 50% of their body weight during 3 min. One trial without vibration, one trial with the frequency of 40 Hz and amplitude of 2 mm and one trial with the frequency of 40 Hz and amplitude of 4 mm. Results: The results showed no difference between the three experimental trials in relative and absolute oxygen uptake. However, the metabolic power and energy expended in whole body vibration (2 mm) were significantly different from exercise without vibration. The data analysis also showed a significant difference in rating of perceived exertion with whole body vibration (4 mm) compared with the exercise without vibration. Results showed that the addition of vibration stimulus has an increase in the energy expenditure particularly with 40 Hz and 2 mm amplitude, suggesting that the high metabolic power during heavy resistance training could be increased by the addition of vibration stimulation. Conclusions: Involuntary contractions generated by the vibration can be used by coaches to increase the intensity of heavy resistance training or to increase the energy expended during the workouts if the goal is a decrease of body mass.
EN
Aim. The aim of this study was to measure aerobic demands of fire fighting activities including exercise in the heat. Methods. Twenty-two experienced firefighters performed the Trondheim test simulating fire fighting tasks including work in the heat. Maximal oxygen uptake (VO2 max), heart rate (HR) and ventilation were recorded continuously. Data were compared with results obtained during a treadmill test during which the participants were dressed as smoke divers. Results. The participants completed physical parts of the Trondheim test in ~12 min (range: 7.5–17.4). Time to complete the test was closely related to the participant’s VO2 max. HR of ~170 beats/min and pulmonary ventilation of ~100 L/min were higher than at lactate threshold (LT) during laboratory tests. VO2 averaged over the test’s physical part was 35 ± 7 ml/min/kg, which was at the same or below the level corresponding to the participants’ LT. Physically fit participants completed the test faster than less fit participants. Slower and physically less fit participants consumed more air and used more oxygen than faster and physically more fit participants. Conclusion. The Trondheim test is physically demanding; it distinguishes physically fit and less fit participants.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.