Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 27

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  radiometry
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The spectral energy, Eλ (in J·g–1·sr–1), of a model obscurant composition containing red phosphorus (P(red), 59 wt.%), Zr (15 wt.%), potassium nitrate (KNO3, 21 wt.%) and a polyacrylate binder (5 wt.%), was determined in band II (λ = 3-5 μm) and band V (λ = 8-14 μm). The spectral energy obtained in band V was higher than the spectral energy in band II. The band ratio V/II and spectral energy indicated that the combustion flame of the pyrolant cannot be described as a graybody. A combined DTA/TG analysis under anaerobic conditions revealed an initial exotherm followed by an endothermic process, the latter coinciding with a mass loss of >40 wt.%, indicative of the vaporization of P(red).
PL
Badania zostały przeprowadzone na siedmiu próbkach skał mioceńskich pobranych z rdzenia wiertniczego. Wybrany materiał reprezentował piaskowce, mułowce oraz iłowce. Głównym celem pracy było wydzielenie frakcji pylastej (silt) i określenie jej wpływu na poziom radioaktywności skał miocenu zapadliska przedkarpackiego. W badaniach została wykorzystana metoda wydzielania frakcji pylastej opracowana w Zakładzie Geofizyki Wiertniczej INiG – PIB. Do określenia wielkości siltu wykorzystano klasyfikację Wentwortha, przyjmując jego zakres od 4 µm do 63 µm. Wytypowany materiał skalny przygotowywany był wieloetapowo z zastosowaniem metod zamrażania, przesiewania, wirowania i sedymentacji. W celu określenia typu skał i ich własności wykonano badania pomocnicze, w tym analizy mineralogiczne XRD, chemiczne XRF oraz pomiary gęstości właściwej. Dla określenia zawartości naturalnych pierwiastków promieniotwórczych przeprowadzono szereg badań radiometrycznych. Analizy wykonano na niewielkiej liczbie prób z powodu ich długotrwałego przygotowywania oraz ograniczonej dostępności materiału. Wiarygodne wyznaczenie parametrów poszczególnych frakcji ziarnowych wymagało weryfikacji i udoskonalenia zastosowanych metod badawczych. Pomiary radiometryczne określające naturalną zawartość potasu 40K, uranu 238U oraz toru 232Th wykonano w aparaturze RT-50, wyposażonej w trzycalowy kryształ NaI(Tl). W pierwszej kolejności przeprowadzono standardowe analizy wysuszonych i skruszonych próbek iłowców, mułowców i piaskowców mioceńskich. Kolejne pomiary wykonano na wydzielonej frakcji siltowej oraz – w przypadku jednej próbki – także na pozostałych frakcjach (ilastej i piaszczystej). W tym wypadku analizy prowadzone były wielokrotnie z zastosowaniem nowej procedury umożliwiającej wyznaczenie pierwiastków promieniotwórczych w próbkach o niskiej masie. Wyniki pracy pozwoliły na przybliżone określenie naturalnej promieniotwórczości gamma frakcji pylastej (siltu). Istotnym wnioskiem z pracy jest to, że sam silt nie jest bardziej promieniotwórczy od pozostałych składników skały. W pracy podjęto również próbę określenia wpływu zawartości minerałów ciężkich na naturalną promieniotwórczość badanych skał. W tym celu z próbek skał odseparowano minerały o gęstości powyżej 2,85 g/cm3 i ponownie przeprowadzono serię analiz. Otrzymane wyniki były minimalnie zaniżone, jednak na tyle zbliżone do uzyskanych na próbkach przed separacją, że można wyciągnąć wniosek o braku wpływu minerałów ciężkich na całkowitą radioaktywność skał w badanym rejonie.
EN
The research was performed on seven samples of Miocene rocks collected from the core. The selected material was represented by sandstones, mudstones and claystones. The main goal of the work was to separate the silt fraction and to determine its impact on the level of radioactivity of the Miocene rocks of the Carpathian Foredeep. In this study, the silt fraction separation method developed in the Well Logging Department of INiG – PIB was used. Wentworth classification was used to determine the size of the silt, assuming its range from 4 to 63 µm. The selected rock material was prepared in several stages using the methods of freezing, sieving, centrifugation and sedimentation. Additional tests, including mineralogical XRD, chemical XRF and matrix density measurements were performed to determine the rock types and their properties. A number of radiometric tests were performed to determine the content of natural radioactive elements. The analyses were carried out on a small number of tests because of their long preparation and limited material availability. Reliable determination of the parameters of individual grain fractions required verification and improvement of the applied research methods. Radiometric measurements determining the natural content of potassium 40K, uranium 238U and thorium 232Th were carried out in the RT-50 equipped with a three-inch NaI(Tl) crystal. In the first place, standard analyses were conducted for dried and crushed samples of Miocene claystones, mudstones and sandstones. Further measurements were made on the separated silt fraction and in the case of one sample, also on the remaining fractions (clay and sand). In this case, the analyses were carried out repeatedly using a new procedure enabling the determination of radioactive elements in low-mass samples. The results of the work allowed approximate determination of the natural gamma radioactivity of the silt. An important conclusion is that, silt is no more radioactive than the other components of the rock. This paper also attempted the estimation of the impact of heavy mineral content on the natural radioactivity of the Miocene rocks. For tests purpose, minerals with a density above 2.85 g/cm3 were separated from the rock samples and a series of analyses were carried out once again. The obtained results were minimally understated but close enough to the samples before separation. It can be concluded that the heavy minerals in the tested samples do not affect the total radioactivity of the rocks in the research area.
EN
The area which transcends the Precambrian basement complex onto the Sokoto sector of the Iullemmeden basin in northwestern Nigeria presents a unique prospect for geothermal exploration research in the absence of regional heat production data, despite its tectonic history and depositional characteristics. In this study, geophysical exploration employing radiometric technique was adopted to classify the petrologic units within the fringes of the Iullemmeden basin and the adjoining crystalline basement complex so as to estimate the radiogenic heat potential within the terrain that may support geothermal considerations. Airborne radiometric measurements acquired over the area were digitized and processed to obtain radioelement concentration maps and the K/Th/U ternary map. Results show that the ranges of measured concentrations of 40K, 238U and 232Th are 4.6 to 18.9%, 0.7 to 4.9 ppm and 4.6 to 18.9 ppm respectively. Radiogenic heat estimation derived from radioelement data within eight petrologic units comprising quaternary sediments, schist, carbonates, shale/clay, younger granites, older granites, gneissic rock and migmatite showed that the lowest radiogenic heat production estimates ranging from 0.27–0.66 µW∙m−3 were recorded in the sedimentary terrain within the quaternary sediments while the highest radiogenic heat production values of between 2.04 to 2.34 µW∙m−3 were recorded in the basement complex within gneissic rocks. The spatial distribution of radiogenic heat in the area showed an increased heat gradient within the basement complex and a diminishing heat gradient over the Iullemmeded basin.
PL
W pracy przedstawiono nową metodykę pomiarową spektrometrii gamma dla rdzeni wiertniczych reprezentowanych przez skały o niskiej aktywności. Opisano w niej części składowe nowo zaprojektowanego spektrometru wraz z dedykowanym oprogramowaniem testowym. Badania prowadzone według zaproponowanej procedury stosowane są głównie do rdzeni formacji piaskowcowych czerwonego spągowca, dla których dotychczas w Polsce nie wykonywano pomiarów gamma. Pierwsze testy na rdzeniach piaskowcowych prowadzono z wykorzystaniem standardowego spektrometru – gamma logger BGO (GL), przy wydłużonym czasie pomiarowym, co pozwoliło uzyskać zaledwie częściowe wyniki dla wybranego odcinka rdzenia. Opracowanie nowego urządzenia wykorzystującego dwa niezależnie mierzące detektory BGO, umieszczone pod kątem 90 stopni w ołowianym tunelu (aparatura GLGT) umożliwiło dwukrotne skrócenie czasu pomiarowego, poprawienie dokładności wyników oraz obniżenie poziomu detekcji dla analizowanych pierwiastków (potas, uran oraz tor). Wstępne badania porównawcze w otworze testowym ukazały różnice pomiędzy aparatem GL i GLGT. Polegały one na poprawie jakości rejestrowanych danych w szczególności dla uranu i toru, które w przypadku standardowych analiz przyjmowały wartości mniejsze od tła pomiarowego. Dodatkowe badania przeprowadzono na wzorcach kalibracyjnych w postaci walca o znanej koncentracji pierwiastków promieniotwórczych, których wyniki posłużyły głównie do oceny rozdzielczości obu metod. Seria pomiarów rdzeni z otworu J-1 pozwoliła otrzymać dokładne wyniki porównawcze z aparatów GL i GLGT, które przedstawiono na tle profilowań geofizyki otworowej oraz badań laboratoryjnych. W przypadku tego testu wyniki z aparatury GLGT wykazały się poprawą dokładności, lepszym dopasowaniem do profilowań oraz poprawą rozdzielczości pionowej w stosunku do geofizyki wiertniczej. Uzyskane wyniki pomiarów spektrometrem GLGT wykorzystano do określenia tła pomiarowego, szacunkowej rozdzielczości oraz określenia dokładnych zawartości potasu, uranu i toru w otworach archiwalnych. Wyniki końcowe przedstawiono w postaci krzywych spektrometrycznego profilowania gamma.
EN
This paper shows a new methodology of gamma spectrometry measurements dedicated to cores represented by rocks of low radioactivity. It describes the components of the newely developed spectrometer and the dedicated testing software. The measurements conducted according to the proposed procedure are mostly applied for Rotliegend formation cores, for which spectral gamma core logging has never been done before in Poland. The first tests on the sandstone cores were conducted using a standard spectrometer – gamma logger BGO (GL) with an extended measurement time, which allowed obtain partial results for chosen core interval. The construction of the new device, which uses two independent BGO detectors placed at a 90-degree angle in lead tunnel shielding (GLGT apparatus), made it possible to twice shorten the measurement time, improve the accuracy of the results, and reduce the detection limit for the analysed elements (potassium, uranium, thorium). Preliminary comparative studies performed on the core from the test borehole showed differences between gamma logger GL and the GLGT device. These differences were visible especially for uranium and thorium data, which in the case of standard (GL) surveys carried values that were lower than the measurement background. Additional measurements were carried out on calibration standards in the form of a cylinder with a known concentration of radioactive elements, the results of which were used for evaluating the core logging resolution of both methods. The series of core measurements from J-1 borehole allowed to obtain accurate comparative results from GL and GLGT devices, which were presented against well logging and laboratory analyses. In the case of this test, the results from GLGT apparatus showed an improvement in measurement accuracy, better fitting to the well logs, and a higher vertical resolution in relation to spectral gamma logs. The results of the measurements performed with a GLGT spectrometer were used to define the measurement background, the estimated resolution, as well as to define the accurate content of potassium, uranium and thorium in the archival boreholes. All the final results were presented as curves of spectral gamma logs.
EN
Geological lineaments, depths to the basement, uranium concentra-tions, and remobilization in parts of the Upper Benue Trough, covering about 55 × 55 km2 (longitudes 11°30′–12°00′E and 10°30′–10°30′N), Northeastern Nigeria were investigated using integrated High-Resolution Aeromagnetic Data (HRAD) and radiometric data. This was with a view to identifying the potential zones of uranium occurrence in the area. The HRAD was processed to accentuate anomalies of interest and depths es-timate of 150–1941 m were obtained from source parameter imaging technique. The results from the superposition of the horizontal gradient magnitude, analytical signal amplitude, first vertical derivative, and 3D Euler solutions of the HRAD revealed that the study area was dissected by linear structures that trend ENE–WSW, NE–SW, E–W, NNE–SSW, WNW–ESE, and NW–SE; among which the ENE–WSW and NE–SW trends dominated. Analyses of radiometric data showed that uranium ores in the study area were possibly remobilized epigenetically from the granitic rocks, and were later deposited into sedimentary rocks (Bima formation). Burashika group (Bongna hills) and Wawa area of the study area showed vein-type deposits, while the anatectic migmatite in the northeastern region and the uranium rich Bima formation showed both fault/fracture and contact types of deposition. It was also observed the northwesterly and southeasterly, dominant dip direction, dipping faults dip in the same direction as the paleocurrent direction (direction of depositions of sediments), and trend in a direction perpendicular to the hypo-thetical direction of uranium deposition. The study concluded that the studied area is dissected by several linear structures and the studied area possibly contains deposits of uranium ore, which are likely to be found in: the Bima Sandstones of Wade, Shinga, Bima hill, Wuyo, Teli, Bryel, Dali, Barkan, Gasi, Kunkun, Boragara, Deba, and Gberundi localities; the anatectic migmatite at Kubuku, Whada, and Hyama; and the Bongna hills and agglomerates around Burashika, Kawaba, and Galu.
PL
Na przestrzeni wieku, od odkrycia przez Wiliama Roentgena promieni X oraz promieniotwórczości przez Henriego Becquerela, nastąpił dynamiczny rozwój fizyki jądrowej, detekcji promieniowania i jego zastosowań. Powszechnie stosowane w radiologii lekarskiej i dozymetrii indywidualnej błony fotograficzne zostały zastąpione przez współczesne metody radiometryczne. Jedną z zaawansowanych metod radiometrycznych będących obecnie w powszechnym użyciu jest spektrometria promieni γ oparta na właściwościach detekcyjnych czystego germanu. Jednym z najbardziej skomplikowanych urządzeń jądrowych jest tokamak. W budowie jest największy jak do tej pory tokamak ITER. Bedzie on podstawą do budowy komercyjnych, energetycznych reaktorów syntezy. Technika aktywacyjna bazująca na współczesnej spektrometrii γ ma zastosowanie w badaniach podstawowych i aplikacyjnych z zakresu fizyki plazmy. Stosuje się ją do badania całkowitego wydatku neutronowego urządzeń plazmowych oraz do ich charakteryzacji.
EN
During the century that pas away from the discovery of X rays by William Roentgen and the radiation by Henry Becquerel the dynamic development of nuclear physic as well as radiation detection and its application has been observed. The nuclear emulsion commonly used in radiology and individual dosimetry has been replaced by current radiometric methods. One of the most advanced currently in use radiometric method is γ spectrometry based on detection properties on high purity germanium. The one of most advanced application of nuclear technology is a tokamak. The biggest to date tokamak ITER is in build so far. The commercially available nuclear power plan will based on the above. The activation technique that based on contemporary γ gamma spectrometry has application in basic researches and development on plasma physics. It has its own application for neutron budget prediction of plasma devices as well as their neutron characterisation.
PL
Na przestrzeni wieku, od odkrycia przez Wiliama Roentgena promieni X oraz promieniotwórczości przez Henriego Becquerela, nastąpił dynamiczny rozwój fizyki jądrowej, detekcji promieniowania i jego zastosowań. Powszechnie stosowane w radiologii lekarskiej i dozymetrii indywidualnej błony fotograficzne zostały zastąpione przez współczesne metody radiometryczne. Jedną z zaawansowanych metod radiometrycznych będących obecnie w powszechnym użyciu jest spektrometria promieni γ oparta na właściwościach detekcyjnych czystego germanu. Jednym z najbardziej skomplikowanych urządzeń jądrowych jest tokamak. W budowie jest największy jak do tej pory tokamak ITER. Bedzie on podstawą do budowy komercyjnych, energetycznych reaktorów syntezy. Technika aktywacyjna bazująca na współczesnej spektrometrii γ ma zastosowanie w badaniach podstawowych i aplikacyjnych z zakresu fizyki plazmy. Stosuje się ją do badania całkowitego wydatku neutronowego urządzeń plazmowych oraz do ich charakteryzacji.
EN
During the century that pas away from the discovery of X rays by William Roentgen and the radiation by Henry Becquerel the dynamic development of nuclear physic as well as radiation detection and its application has been observed. The nuclear emulsion commonly used in radiology and individual dosimetry has been replaced by current radiometric methods. One of the most advanced currently in use radiometric method is γ spectrometry based on detection properties on high purity germanium. The one of most advanced application of nuclear technology is a tokamak. The biggest to date tokamak ITER is in build so far. The commercially available nuclear power plan will based on the above. The activation technique that based on contemporary γ gamma spectrometry has application in basic researches and development on plasma physics. It has its own application for neutron budget prediction of plasma devices as well as their neutron characterisation.
EN
This study describes a novel spectral LED-based tunable light source used for customized lighting solutions, especially for the reconstruction of CIE (Commission Internationale de l'Eclairage) standard illuminants. The light source comprises 31 spectral bands ranging from 400 to 700 nm, an integrating cube and a control board with a 16-bit resolution. A minimization algorithm to calculate the weighting values for each channel was applied to reproduce illuminants with precision. The differences in spectral fitting and colorimetric parameters showed that the reconstructed spectra were comparable to the standard, especially for the D65, D50, A and E illuminants. Accurate results were also obtained for illuminants with narrow peaks such as fluorescents (F2 and F11) and a high-pressure sodium lamp (HP1). In conclusion, the developed spectral LED-based light source and the minimization algorithm are able to reproduce any CIE standard illuminants with a high spectral and colorimetric accuracy able to advance available custom lighting systems useful in the industry and other fields such as museum lighting.
EN
Available on the commercial market are a number of algorithms that enable assigning to pixels of a monochrome digital image suitable colors according to a strictly defined schedule. These algorithms have been recently used by professional film studios involved in the coloring of archival productions. This article provides an overview on the functionality of coloring algorithms in terms of their use to improve the interpretation quality of historical, black-and-white aerial photographs. The analysis covered intuitive (Recolored) programs, as well as more advanced (Adobe After Effect, DaVinci Resolve) programs. The use of their full functionality was limited by the too large information capacity of aerial photograph images. Black-and-white historical aerial photographs, which interpretation quality in many cases does not meet the criteria posed on photogrammetric developments, require an increase of their readability. The solution in this regard may be the process of coloring images. The authors of this article conducted studies aimed to determine to what extent the tested coloring algorithms enable an automatic detection of land cover elements on historical aerial photographs and provide color close to the natural. Used in the studies were archival black-and-white aerial photographs of the western part of Warsaw district made available by the Main Centre of Geodetic and Cartographic Documentation, the selection of which was associated with the presence in this area of various elements of land cover, such as water, forests, crops, exposed soils and also anthropogenic objects. In the analysis of different algorithms are included: format and size of the image, degree of automation of the process, degree of compliance of the result and processing time. The accuracy of the coloring process was different for each class of objects mapped on the photograph. The main limitation of the coloring process created shadows of anthropogenic objects, where grey degree values were corresponding to forests.
PL
Na rynku komercyjnym dostępnych jest szereg algorytmów umożliwiających przypisanie pikselom monochromatycznego obrazu cyfrowego odpowiednich barw według ściśle określonego schematu. Algorytmy te są wykorzystywane przez profesjonalne studia filmowe zajmujące się kolorowaniem archiwalnych produkcji. Niniejszy artykuł stanowi przegląd funkcjonalności algorytmów kolorowania w zakresie możliwości ich wykorzystania do poprawy jakości interpretacyjnej historycznych, monochromatycznych zdjęć lotniczych. Przedmiotem analiz były programy intuicyjne (Recolored), a także bardziej zaawansowane (Adobe After Effect, DaVinci Resolve). Ograniczeniem wykorzystania ich pełnej funkcjonalności była zbyt duża pojemność informacyjna obrazu zdjęcia lotniczego. W przypadku monochromatycznych historycznych zdjęć lotniczych, których jakość interpretacyjna w wielu przypadkach nie spełnia kryteriów stawianych opracowaniom fotogrametrycznym, istnieje potrzeba zwiększenia ich czytelności. Rozwiązaniem w tym zakresie może być proces kolorowania obrazów. Autorzy artykułu przeprowadzili badania zmierzające do ustalenia, w jakim zakresie testowane algorytmy kolorowania umożliwiają automatyczną detekcję elementów pokrycia terenu na historycznych zdjęciach lotniczych oraz nadanie im barwy zbliżonej do naturalnej. W badaniach zostały wykorzystane archiwalne monochromatyczne zdjęcia lotnicze powiatu warszawskiego zachodniego udostępnione przez Centralny Ośrodek Dokumentacji Geodezyjnej i Kartograficznej, których wybór wiązał się z występowaniem w ich obrębie różnorodnych elementów pokrycia terenu, takich jak: wody, lasy, uprawy rolne, odkryte gleby, a także obiekty antropogeniczne. W analizie poszczególnych algorytmów zostały uwzględnione: format i rozmiar obrazu, stopień automatyzacji procesu, stopień zgodności wyniku oraz czas przetworzenia. Dokładność procesu kolorowania była różna dla poszczególnych klas obiektów odwzorowanych na zdjęciu. Głównym ograniczeniem procesu kolorowania były cienie obiektów antropogenicznych, których wartości stopni szarości odpowiadały lasom.
PL
Przedstawiono konstrukcję radiometru typu modulacyjnego z zerowym odczytem oraz kompensacją wpływu współczynnika odbicia.
EN
The paper presents design of modulation radiometer with zero reading and compensation of reflectivity.
EN
In this paper we present the accuracy analysis of energy and temperature measurements for testing and productivity improvement of solar collectors. There are presented possibilities of accuracy and resolution increase of solar energetic luminance sensors. The radiometer with electrical substitution was used in the research. The calibration procedure of the radiometer is described. A mathematical model of conversion function for both temperature and temperature difference measurement was developed as well.
PL
W pracy przedstawiono analizę dokładności pomiaru energii słonecznej i temperatury za pomocą radiometrów z elektrycznym zrównoważeniem. W celu zwiększenia dokładności oraz rozdzielczości radiometrów zaproponowano zastosowanie połączonych równołegle miniaturowych sensorów diodowych do pomiaru różnicy temperatury powierzchni absorbującej kolektora słonecznego oraz otoczenia. Dodatkowo, diody te wykorzystano do nagrzewania sensora w czasie kompensowania. Pokazano, że taka konstrukcja sensora radiometrycznego pozwala odtwarzać temperaturę powierzchni przejmującej. Wykazano, że adytywne i multiplikatywne składniki błędów spowodowane rozrzutami technologicznymi napięć początkowych oraz prądów pomiarowych sensorów diodowych mogą być zmniejszone około razy, przy jednoczesnym zwiększeniu czułości w n razy, gdzie n jest liczbą równolegle połączonych diod. Opisano procedurę kalibracji radiometru przy zerowej i bliskiej maksymalnej mocy promieniowania. W pierwszym przypadku można skorygować addytywny, a w drugim – większość multiplikatywnych składników błędu. Zaproponowano schemat blokowy przyrządu do precyzyjnych pomiarów różnicy temperatury. Zastosowano wielokanałowe mierniki rezystancji z platynowymi sensorami temperatury. Do kalibrowania miernika różnicy temperatury wykorzystano precyzyjne miniaturowe rezystory, a do kalibrowania całego toru pomiarowego użyto precyzyjny termostat sterowany programowo. Opisano także konstrukcję stanowiska do pomiarów parametrów kolektorów słonecznych w laboratorium badawczym w Narodowym Uniwersytecie „Lwowska Politechnika”.
PL
Kamery termowizyjne oraz używane w nich matrycowe detektory podczerwieni w procesie produkcyjnym są poddawane procedurze kalibracji i wyznaczania czułości napięciowej na padające na nie promieniowanie. Detektory na stanowisku kalibracyjnym są oświetlane promieniowaniem podczerwonym poprzez specjalne układy optyczne. Każdy układ optyczny zastosowany w torze optycznym wpływa na rozkład promieniowania padającego na powierzchnie matrycy detektorów. W artykule opisano model służący do opisu rozkładu natężenia promieniowania podczerwonego padającego na matryce detektorów podczerwieni z układem optycznym zastosowanym w stanowisku do kalibracji kamer termowizyjnych. W metodzie tej uwzględniono parametry geometryczne i optyczne matrycy detektorów podczerwieni oraz układu pomiarowego. Opracowany model porównano z wynikami symulacji przeprowadzonymi w programie Zemax.
EN
Thermal imagers and used therein infrared array sensors are subject to calibration procedure and evaluation of their voltage sensitivity on incident radiation during manufacturing process. The detectors used in calibration set-up are illuminated by infrared radiation transmitted through a specialized optical system. Each optical system used influences irradiation distribution across an array sensor. In the article a model describing irradiation distribution across an array sensor working with an optical system used in the calibration set-up has been proposed. In the said method optical and geometrical considerations of the array set-up have been taken into account. Proposed model has been venfied with results of simulation carried out in Zemax software.
PL
W niniejszej pracy dokonano specyfikacji i analizy trybów monitorowania radiometrycznego systemów fotowoltaicznych. Przeprowadzono teoretyczne wprowadzenie do teorii detektorów termicznych i fotonowych. Zaprezentowano bilanse promieniowania krótkofalowego, długofalowego oraz bilansowego. Opisano profesjonalne komercyjne radiometry do specjalistycznych pomiarów meteorologicznych. Stwierdzono, że dla uzyskania szczegółowych danych meteorologicznych powinien zostać zastosowany monitoring naukowy. Zaprezentowano wyniki badań własnych w układzie monitorowania globalnego. Stwierdzono, że monitoring globalny jest wystarczającym narzędziem do predestynacji użytecznych zasobów energetycznych.
EN
In the following paper general review of professional radiometers was presented. In introduction different modes of radiometric measuring stations for photovoltaic purposes was pointed out. Background information about thermal and photonic detectors were presented. Short-wave, long-wave and radiation balances was quoted. Professional meteorological radiometers was presented and briefly described. It was stated that for complex radiation data gathering, professional monitoring should be applied. The results of original global monitoring were presented. It was concluded that, there is no necessity to put in a professional monitoring system for daily monitoring of photovoltaic devices.
14
Content available Jak ocenić jakość fotometryczną ortofotomapy?
PL
Automatyzacja produkcji oraz stosunkowo niskie koszty opracowania powodują, że ortofotomapa stała się jednym z ważniejszych a być może najpopularniejszym produktem geoinformatycznym. W sytuacji masowego wykorzystywania ortofotomapy, co widać zwłaszcza w geoportalach internetowych, coraz większej wagi nabiera ocena jakości. O ile jakość geometryczna jest względnie łatwa do oceny to zgoła inaczej jest z jakością radiometryczną. W publikacji zwrócono uwagę na fakt, że w stosunku do ortofotomapy trafniej jest mówić o jakości fotometrycznej niż radiometrycznej. Dla uzasadnienia tezy opisano ogólną różnicę pomiędzy radiometrią a fotometrią a w szczególności przeanalizowano czym jest rozdzielczość radiometryczna a czym fotometryczna. W dalszej części pracy przedstawiono próbę kompleksowego zdefiniowania pojęcia jakość fotometryczna ortofotomapy. Uznano, że jakość fotometryczna ortofotomapy to stopień spełnienia przez obraz (o określonej rozdzielczości geometrycznej) szeregu warunków kształtujących jego przydatność do interpretacji treści. Następnie omówiono poszczególne warunki determinujące jakość fotometryczną podając każdorazowo możliwości ilościowej oceny spełnienia danego warunku.
EN
The automation of the production and relatively low costs of development imply that the orthophotomap is one of the more important and probably the most popular geo-information technology product. Due to the global application of the orthophotomap as it is particularly evident in case of web geoportals, the quality assessment becomes more and more important. While the geometric quality is relatively easy to assess, it is far more difficult to rate the radiometric quality. The paper emphasises that it is more accurate to employ the term of the photometric quality instead of the radiometric quality in relation to the orthophotomap. In order to prove the thesis, general difference between the radiometry and the photometry was characterised and, in particular, the paper analysed the notions of the radiometric density and of the photometric density. Furthermore, the paper features the concept of the complex definition of the orthophotomap photometric quality. It has been accepted that the orthophotomap photometric quality is the ratio featuring in what way an image (of the specified geometric resolution) complies with a number of conditions defining its usability for the interpretation of the content. Thereafter, individual conditions determining the photometric quality are characterized, specifying each time whether it is possible to assess quantitatively the fulfilment of the given condition.
EN
Adsorption of thiourea (TU) on a polycrystalline copper electrode from 0.01 M NaClO4 solution has been studied by impedance spectroscopy and radiometric method. differential capacity of copper electrode in 0.01 M NaClO4 solution containing TU of concentrations from 10-6 to 5.10-4 M has been measured. The dependencies of the surface concentration of TU on the electrode potential and the bulk concentration were determined radiometrically. The adsorption of TU on the copper electrode was studied in the range of potentials where no faradaic currents occurred. In this range the process of adsorption is practically reversible with respect to the potential and the bulk concen tration of TU. The experimental data were described by the Langmuir and virial isotherms and the Gibbs energy of adsorption was calculated. In order to show the role of the metal the data of TU adsorption on different electrodes have been compared. The unusual behaviour of TU on Cu electrode in comparison with the urea was commented.
16
Content available remote Natural ionizing radiation in some resorts and recreational locations in Lithuania
EN
The results of dosimetric and radiometric analyses of ionizing radiation emitted by natural radionuclides conducted in the Curonian Spit and other recreational locations nearby water reservoirs in Vilnius, Lithuania, are presented. The research was carried out with mobile measuring instruments, data registration and accumulation equipment, applying Global Positioning System. The distribution of equivalent dose rates in the locations has been measured. Soil samples were taken from the locations where equivalent dose rate was measured and specific activities of major gamma radiators were evaluated using spectrometric analysis. The coefficient correlation was detected between 40K, 226Ra, 232Th and 137Cs specific activities and equivalent dose rates above sample collection location. The coefficient of correlation between 40K and 226Ra specific activity in soil and in bottom mud water is identified.
PL
Przedstawiono wyniki dozymetrycznych i radiometrycznych pomiarów naturalnego promieniowania jonizujacego na terenia Mierzei Kurońskiej. Badania prowadzono, korzystajac z przenośnego urządzenia rejestrującego wyposażonego w system GPS. Stwierdzono korelację między aktywnością promieniotwórczą radionuklidów 40K, 226Ra, 232Th i l37 Cs a równoważną dawką promieniowania jonizującego w miejscach pomiarów. Zaobserwowano również korelację między aktywnością promieniotwórczą radionuklidów 40K i 226 Ra w glebie i osadach dennych.
PL
W dziedzinie techniki zajmującej się pomiarami odebranego promieniowania wyróżnia się radiometrię szumową związaną z detekcją promieniowania o strukturze szumowej, którego widmo mieści się w paśmie mikrofalowym. Źródłem tego promieniowania są organizmy żywe oraz przedmioty i substancje, których temperatura jest wyższa od zera bezwzględnego. Pomiar tego rodzaju promieniowania jest realizowany za pomocą radiometru mikrofalowego składającego się z anteny (głowicy pomiarowej), wzmacniacza z detektorem oraz wyjściowego układu analizującego i rejestrującego. W artykule przedstawiono zasadę działania i parametry robocze radiometru modulacyjnego pracującego na częstotliwości 1,5 GHz. Opisano wybrane wyniki prac badawczych prowadzonych w Zakładzie Mikrofal IRE WEL WAT nad bezinwazyjnymi metodami lokalizacji stanów patologicznych wewnątrz organizmów żywych oraz biernymi systemami wykrywania obiektów o temperaturze fizycznej wyższej lub niższej niż temperatura ich otoczenia. Przedstawiono wyniki badań eksperymentalnych weryfikujących przyjęte hipotezy.
EN
Microwave thermal radiation of various objects can be used for their location and identification. Thermovision in the infrared range enables us to find temperature distribution on the object surface while microwave radiometers allow us to recognize "hot" objects placed, for instance, behind thermal shields. Microwave radiometers are used, among the others, in health care and in so-called special applications. In medicine, they are used both in diagnostics and therapy where, for example, microwave radiometers control temperature in hypo- or hyperthermia or they can monitor pathological states of internal organs, detect pap tumour, or are used for temperature measurements of acupunctural points. Special applications of microwave radiometers focus on passive location of various equipment like tanks, planes, cars, trucks and so on. A separate group of applications deals with detection of humans or "hot" objects located behind shields. Performed experiments confirmed capability of developed radiometer to remote detection of live objects and subjects with temperatures different from the background. The tested instrument was equally effective in observation of non-shielded objects as well as for objects hidden behind dielectric shield. The principle of operation of the 1.5 GHz microwave radiometer and selected results of the experiments there were presented.
18
Content available remote Pomiary pyranometryczne na stanowisku SGGW-URSYNÓW
PL
W Zakładzie Elektrotechniki i Automatyki Wydziału Inżynierii Produkcji, na terenie SGGW w Warszawie - Ursynowie, utworzono w 1988 roku stanowisko do pomiarów napromieniowania całkowitego powierzchni pochyłej o południowej wystawie. Pomiary wykonywano w sposób ciągły, a wyniki były automatycznie zapisywane do pamięci komputera. Zebrane do 2000 roku wyniki pomiarów posłużyły do opracowania modelu deterministycznego napromieniowania powierzchni pochyłej. w 2005 roku uruchomiono nowe stanowisko meteorologiczne zintegrowane z pracownią pyranometryczną. Zasadniczym zadaniem stanowiska jest pomiar natężenia promieniowania słonecznego całkowitego z wykorzystaniem pyranometrów firmy Kipp&Zonnen na trzech płaszczyznach: poziomej, nadążnej za ruchem pozornym Słońca oraz eksponowanej południowo z elewacją dostosowaną do maksymalnej wysokości w danym dniu. Pracownia pyranometryczna pozwala na szeroki zakres badań, w tym na: porównanie sum godzinowych, dobowych i okresowych promieniowania słonecznego na badanych płaszczyznach, ocenę zasobów energii słonecznej na płaszczyźnie południowej jako kontynuację badań z lat 1988-2000 i rozwijanie koncepcji modeli napromieniowania płaszczyzny pochyłej.
PL
Przeprowadzono analizę przydatności radiometru RUM-1 do badań terenowych skażeń cezu (137Cs). Opisano procedurę przygotowania radiometru do pracy i metodykę analizy kartograficznych pomiarów terenowych i analizy profili glebowych. Podstawowym parametrem jest napięcie pracy radiometru warunkujące ilość zliczanych impulsów gamma. W celu zapewnienia stabilności wyników konieczne było określenie przedziału napięć w jakim krzywa wydajności ma charakter płaski (plateau). Drugim problemem była optymalizacja czasu pomiarów. Przeprowadzona analiza błędu standardowego dla serii po 30 pomiarów dla różnych długości czasu wskazała, że optymalny czas pomiaru powinien być rzędu 1000 s. Mimo trudności z utrzymaniem kalibracji energetycznej kanałów w warunkach terenowych sprzęt ten w pełni umożliwia analizę aktywności 137Cs, także w warunkach terenowych, ponieważ pik cezowy jest łatwy do wyodrębnienia na wykresie.
EN
Application of RUM-1 radiometer for field mapping of 137 Cs activity has been analysed. Setting up of instrument parameters has been described. Optimal voltage has been established as a plateau region of intensity versus voltage curve. Time of measurements has been established after standard error analysis applied to results of 30 series of measurements of different measurement time-Optimal time was found to be 1000 s. In spite of difficulties with energetic calibration 137Cs " analysis is possible due to distinct character of cesium peak on obtained graphs.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.