Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  rachunek różniczkowy niecałkowitego rzędu
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In recent years the use of fractional calculus in control system identification is becoming popular and it has found new applications. The paper presents application of fractional calculus for modelling of two-phase gas/liquid flows in a test rig. The installation consists of three horizontal and vertical measuring segments with different diameters, which allow to investigate flows in a wide range of parameters. Flow components supply is measured/controlled by NI PXI system and a set of flow meters/controllers. The paper presents model of the two-phase flow in the above described installation, which leads to precise and accurate flow mathematical model. The main goal of the flow model is to describe steady flow parameters, especially the flow fractions, or type of the flow. The model describes flows more accurately, that classical second order system model.
PL
W ostatnich latach wykorzystanie rachunku różniczkowego niecałkowitego rzędu staje się coraz bardziej popularne i znajduje nowe obszary zastosowań. W pracy przedstawiono zastosowanie powyższego rachunku różniczkowego do modelowania przepływów dwufazowych gaz / ciecz. Instalacja badawcza składa się z trzech poziomych i pionowych odcinków pomiarowych o różnych średnicach, które umożliwiają badanie przepływu w szerokim zakresie parametrów. Przepływ komponentów mieszaniny jest mierzony / sterowany przez system NI PXI oraz zestaw przepływomierzy i sterowników. W artykule przedstawiono modelowanie przepływu dwufazowego w wyżej opisanej instalacji, które prowadzi do określenia precyzyjnego modelu matematycznego przepływu. Opracowany model opisuje przepływy dwufazowe dokładniej w porównaniu z klasycznym model opisanym równaniami różniczkowymi drugiego rzędu.
EN
The purpose of this paper is to compare responses of two systems with two types of controllers: integer order PI controller and non-integer order PI controller (FOPI). Comparison is made on the grounds of time domain responses of waters level in tank. In order to design both of the controllers, numerical model is established and described. Synthesis method with use of simulated annealing optimisation method is developed for each controller. In order to do a correct comparison, the two control systems have the same designing parameters. Matlab/Simulink environment and numerical model are used to do the computing. Numerically designed controllers are verified experimentally with tank system. The obtained results show that using non-integer order PIl controller instead of a ”traditional” PI controller in simple integrating systems is useless.
PL
W artykule porównano odpowiedzi układów z dwoma regulatorami: typu PI oraz typu PI niecałkowitego rzędu. W celu syntezy regulatorów, stworzono i opisano model numeryczny, a następnie wykorzystano metodę symulowanego wyzarzania do znalezienia optymalnych parametrów. Tak zaprojektowane regulatory zostały przetestowane na rzeczywistym zbiorniku. W rezultacie okazało się, że zastosowanie regulatora niecałkowitoliczbowego rzędu do układu całkującego nie jest konieczne. Obliczenia były prowadzone w środowisko Matlab/Simulink.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.