Frequency of a pulse signal at the test output of a static electricity meter is proportional to the active power of a connected load. When the consumed power changes, time between adjacent pulses of the test signal changes too, which prevents from obtaining the results of power measurement at regular time intervals. This work presents an algorithm for digital processing of a pulse frequency signal from the test output of a static electricity meter in order to obtain instantaneous values of active power at regular time intervals.
PL
Częstotliwość sygnału na wyjściu testowym statycznego licznika energii elektrycznej jest proporcjonalna do mocy czynnej dołączonego obciążenia. Gdy ta moc zmienia się, czas pomiędzy kolejnymi impulsami sygnału testowego również się zmienia, co uniemożliwia uzyskanie wyników pomiarów mocy w regularnych odstępach czasu. W pracy prezentuje się algorytm cyfrowego przetwarzania sygnału częstotliwościowego z wyjścia testowego licznika energii elektrycznej w celu uzyskania wartości chwilowych mocy czynnej w regularnych odstępach czasu.
PL
Częstotliwość sygnału na wyjściu testowym statycznego licznika energii elektrycznej jest proporcjonalna do mocy czynnej dołączonego odbiornika. Gdy moc ta ulega zmianie, zmienia się czas pomiędzy kolejnymi impulsami sygnału testowego, co uniemożliwia uzyskanie wyników pomiaru mocy w równych odstępach czasu. W pracy przedstawia się algorytm cyfrowego przetwarzania impulsowego sygnału częstotliwościowego z wyjścia testowego statycznego licznika energii elektrycznej w celu uzyskania chwilowych wartości mocy czynnej w równych odstępach czasu.
EN
The indications of electricity meters are a basis for the financial settlements for consumed electric energy. Therefore, they are subjected to appropriate regulations and their design must fulfil proper requirements. All static electricity meters must have an output of the test signal allowing for determination of the measurement errors of the meter during its legalization. It also gives additional possibilities of analyzing the load variation in the installation place, as the frequency of the pulse signal on the test output is proportional to the active power of the connected device. In order to precisely determine the frequency of the test signal in short time, it is required to measure its successive periods. But if the device power changes, the successive results of measurements are obtained in various time intervals. It makes the analysis of load variation in reference to the linear time scale more difficult. The paper presents the range of issues connected with the digital processing of the impulse frequency signal from the test output of a static electricity meter in order to obtain the instantaneous values of the active power in equal time intervals. The algorithm of obtaining the uniformly sampled frequency signal upon the basis of non-uniformly located samples is presented. It uses the multinomial approximation of the value of electric energy measured by the meter, which after calculation of derivative allows for determination of the value of the active power in selected time instants. Appropriate analytical dependences and examples of measurements results are also given.
PL
W pracy przedstawia się problematykę równomiernego próbkowania sygnału częstotliwościowego w systemie pomiarowym, w którym chwilowe wartości częstotliwości reprezentują chwilowe wartości przetwarzanej wielkości, a czas pomiędzy próbkami zależy od aktualnej wartości sygnału wejściowego. Taki sygnał można analizować za pomocą prezentowanego algorytmu resamplingu z wielomianową aproksymacją fazy sygnału impulsowego, a jakość przetwarzania ocenić efektywną liczbą bitów. Prezentuje się wybrane wyniki badań.
EN
This paper focuses on issues relating to the extraction of a uniform sampled frequency signal from irregularly spaced samples. In the measurement system with a frequency output sensor instantaneous frequency values represent instantaneous values of the processed quantity and the time between samples depends on the current value of the input signal. This non-uniformly sampled signal can be analyzed by the discussed resampling algorithm with polynomial interpolation of the pulse signal phase. In this case, a convenient parameter for assessing the processing quality of such a measurement chain is the effective number of bits. The presented algorithm can be applied in all the cases when the pulse signal frequency carries information about instantaneous values of a physical quantity processed in the system. This allows testing various digital processing algorithms of frequency signals and assessing the errors introduced by them. The selected test results are also presented in the paper.