Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pyridoxine hydrochloride
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Two methods were presented for the simultaneous determination of two multicomponent mixtures containing pyridoxine hydrochloride (B6) and cyanocobalamine (B12) with benfotiamine (BN) [mix. 1], or thiamine nitrate (B1) and diclofenac sodium (DC) [mix. 2]. The first high-performance liquid chromatographic (HPLC) method depends on the use of a cyanopropyl column at a flow rate of 1.5 mL min-1 with a mobile phase consisting of acetonitrile-25 mM ammonium acetate, pH 3.7 (10:90, v/v), for mix. 1 or acetonitrile-25 mM ammonium acetate, pH 5.0 by gradient elution, changing the proportion of the system linearly with a time schedule program, for mix. 2. Quantitation was achieved by UV detection at 220 nm. The second method was based on HPTLC separation followed by densitometric measurement of the spots at 254 nm. The separation was achieved on HPTLC silica gel F254 plates using chloroform-ethanol-water-acetic acid (5:8:2:0.5, v/v/v/v) for mix. 1 and chloroform-ethanol-water-acetic acid (1.5:8:2:0.5, v/v/v/v) for mix. 2. The proposed methods were successfully applied for the analysis of pharmaceutical formulations containing the two multicomponent combinations.
EN
A simple, rapid and precise liquid chromatographic method for simultaneous determination of pyridoxine hydrochloride. isomazid, pyrazmamide and rifampicin in a tablet dosage form has been developed Chromatographic analysis was performed on a 250 x 4.6 mm I.D. C|8 column packed with 5 μm-in-size particles applying gradient elution with a mobile phase composed of acetonitrile (A) and 15 mmol L-1 potassium dihydrogen phosphate buffer of pH adjusted to 4.0 J: 0.1 with o-phosphoric acid (B). A:B ratio was 11:89 v/v for the initial 4.5 min. and then it was maintained at 50:50 v/v; the flow rate was 1 mL min-1UV detection was performed at 235 nm. The total run time was 20 mm. Retention times for pyridoxine hydrochloride, isoniazid, pyrazmamide and rifampicin were 3.687, 4.113, 5.041 and 12.829 min, respectively The method was validated with respect to linearity, accuracy, . precision, specificity and sensitivity in accordance with ICH guidelines. Limits of detection were 0.043. 0.063. 0.036 and 0.059 μg mL--1'and limits of quantification were 0.13, 0.19, 0.11 and 0.18 μg ml, ' for pyridoxine hydrochloride, isoniazid, pyrazinamide and rifampicin, respectively. High recovery and low coefficients of variance confirmed the suitability of the method for the simultaneous analysis of the four considered drugs.
PL
Opracowano prostą, szybką i precyzyjną procedurę jednoczesnego oznaczania chlorowodorku pirydoksyny, izoniazydu, pirazynamidu i rifampicyny w tabletkach za pomocą chromatografii cieczowej. Analizę chromatograficzną prowadzono przy użyciu kolumny 250 x 4,6 mm. napełnionej faząC18 o wielkości cząstek wynoszącej 5 urn. Zastosowano gradient fazy ruchomej składającej się z acetonitrylu (A) i buforu w postaci fosforanu dihydropotasowego o stężeniu 15 mmol L-1 i pH = 4 š 0, l ustalonego za pomocą kwasu o-fosforowego (B). Stosunek A i B wynosił 11:89 v/v przez 45 min, następnie był utrzymywany stosunek 50:50 v/v. Przepływ fazy ruchomej wynosił l mL min"1. Całkowity czas rozdzielania składników mieszaniny wynosił 20 min. Detekcję UV prowadzono przy 235 nm. Czasy retencji chlorowodorku pirydoksyny, izoniazydu, pirazynamidu i rifampicyny wynosiły odpowiednio 3.687; 4,113; 5,041 i 12,829 min. Opracowaną procedurę walidowano uwzględniając liniowość, dokładność, precyzję, specyficzność i czułość, zgodnie z zaleceniami Międzynarodowej Konferencji Harmonizacyjnej (ICH). Wykrywalności wynosiły 0.043; 0.063; 0.036 i 0,059μg mL-1a oznaczalności 0,13; 0,19; 0,11 i 0,18 μg mL-1 odpowiednio dla chlorowodorku pirydoksyny, izoniazydu, pirazynamidu i rifampicyny. Wysoki odzysk i małe współczynniki wariancji potwierdziły przydatność metody do jednoczesnej analizy czterech leków.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.