Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pump station
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Purpose: The study aims to diagnose the corrosion current density in the coating defect on the outer surface of the ammonia pipe depending on the distance to the pumping station, taking into account the interaction of media at the soil-steel interface and using modern graphical data visualization technologies and approaches to model such a system. Design/methodology/approach: The use of an automated system for monitoring defects in underground metallic components of structures, in particular in ammonia pipelines, is proposed. The use of the information processing approach opens additional opportunities in solving the problem of defect detection. Temperature and pressure indicators in the pipeline play an important role because these parameters must be taken into account in the ammonia pipeline for safe transportation. The analysis of diagnostic signs on the outer surface of the underground metallic ammonia pipeline is carried out taking into account temperature changes and corrosion currents. The parameters and relations of the mathematical model for the description of the influence of thermal processes and mechanical loading in the vicinity of pumping stations on the corresponding corrosion currents in the metal of the ammonia pipeline are offered. Findings: The paper evaluates the corrosion current density in the coating defect on the metal surface depending on the distance to the pumping station and the relationship between the corrosion current density and the characteristics of the temperature field at a distance L = 0…20 km from the pumping station. The relative density of corrosion current is also compared with the energy characteristics of the surface layers at a distance L = 0…20 km from the pumping station. An information system using cloud technologies for data processing and visualization has been developed, which simplifies the process of data analysis regarding corrosion currents on the metal surface of an ammonia pipeline. Research limitations/implications: The study was conducted for the section from the pumping station to the pipeline directly on a relatively small data set. Practical implications: The use of client-server architecture has become very popular, thanks to which monitoring can be carried out in any corner of the planet, using Internet data transmission protocols. At the same time, cloud technologies allow you to deploy such software on remote physical computers. The use of the Amazon Web Service cloud environment as a common tool for working with data and the ability to use ready-made extensions is proposed. Also, this cloud technology simplifies the procedure of public and secure access to the collected information for further analysis. Originality/value: Use of cloud environments and databases to monitor ammonia pipeline defects for correct resource assessment.
PL
W artykule przedstawiona została sieć wysokiego ciśnienia, mediów hydraulicznych, w podziemnym zakładzie górniczym Kopalni Węgla Kamiennego (KWK). Sieć ta pozwala w skuteczny sposób dostarczyć medium do zasilania odbiorników, wykorzystujących hydraulikę siłową oraz stosowanych do tego celu środków technicznych. Zakres artykułu obejmuje przedstawienie pojęcia hydrauliki siłowej dotyczącej wykorzystania oraz zaplanowania układów hydraulicznych. Przedstawia medium, jego zadania oraz rodzaje cieczy hydraulicznych stosowanych w hydraulice siłowej w górnictwie podziemnym. Pokazano zastosowany model sieci wysokiego ciśnienia, czyli opis wytwarzania emulsji olejowo-wodnej i dostarczania jej do miejsc przetwarzania energii elektrycznej na energię hydrauliczną, transport do odbiorników hydraulicznych oraz ich zasilanie – przedstawiono także drogę powrotu medium do pompowni.
EN
The article presents a high-pressure hydraulic network in an underground mining plant (coal mine). This network allows to effectively provide a medium to power the receivers which are using hydraulics power and the technical sources used for this purpose. The scope of the article includes the presentation of the concept of hydraulic power regarding the use and planning of hydraulic systems. Article presents the medium, its tasks and types of hydraulic fluids used in hydraulics power in underground mining. The highpressure network model used in coal mine is shown by presenting a description of the production of oil-in-water emulsion and its delivery to places where electricity is converted to hydraulic energy, transport to hydraulic receivers and their supply. The way of returning the medium to the pumping station is also presented.
EN
One of the approaches to solve the problem of resource and energy saving in centralized water-supply systems by reducing the total excess pressure in water-supply nodes is examined in the present work. The implementation of this approach is provided due to re-engineering of water-supplies by their zoning and optimal flux-distribution in the water-supplies. Mathematical formulations of the problems to be examined and efficient algorithms of their solving are presented.
4
Content available Energy usage optimisation in South African mines
EN
In recent years, South Africa has encountered a critical electricity supply which necessitated the implementation of demand-side management (DSM) projects. Load shifting and energy (EE) efficiency projects were introduced in mining sector to reduce the electricity usage during day peak time. As the compressed air networks and the water pumping systems are using large amounts of the mines’ electricity, possible ways were investigated and implemented to improve and optimise the energy consumption and to reduce the costs. Implementing DSM and EE in four different mines resulted in achieving the desired energy savings and load-shifting.
PL
W ostatnich latach w Południowej Afryce zanotowano pewne trudności z dostawami energii elektrycznej, co wymusiło wdrożenie działań mających na celu skuteczne zarządzanie zagadnieniami energetycznymi. Wprowadzono działania mające na celu zmianę systemu obciążeń roboczych i bardziej efektywne wykorzystanie energii tak, by obniżyć zapotrzebowanie na energię w trakcie szczytowych godzin w ciągu dnia. Sieci dostarczające sprężone powietrze oraz stacje pomp zużywają znaczne ilości energii w kopalni, przeanalizowano więc możliwe sposoby redukcji i optymalizacji zapotrzebowania na energię i tym samym obniżenia kosztów produkcji. Wdrożenie odpowiednich projektów nakierowanych na oszczędności i optymalizację w czterech kopalniach doprowadziło do oczekiwanych oszczędności energii i umożliwiło zmianę systemu obciążeń roboczych w trakcie procesu produkcji.
PL
W artykule przedstawiono badania przeprowadzone w stacji uzdatniania wody, których celem była analiza przebiegów prądów i napięć zawierających wyższe harmoniczne, które powstają w wyniku pracy urządzeń nieliniowych. Pomiary były przeprowadzane w stacji transformatorów, po stronie wyższego napięcia. Na kształt napięcia miały wpływ wszystkie odbiorniki nieliniowe zainstalowane w zakładzie, zasilane przez tę stację transformatorów. Skutkami występowania wyższych harmonicznych jest zniekształcenie sinusoidy napięcia zasilającego. Obecność wyższych harmonicznych w sieci zasilającej może być przyczyną zakłóceń w pracy urządzeń elektronicznych. W artykule wyznaczono wartości współczynników THD i odniesiono je do wartości określonych stosownymi normami.
EN
The article presents the studies carried out in water treatment plants, which aim was to analyze the current and voltage waveforms contain higher harmonics, they result from the work of non-linear devices. Measurements were carried out in the transformer station on the side of higher voltage. The shape of power to affect all the non-linear loads installed in the Department, powered by the transformer stations. The effects of harmonic distortion is a sine wave voltage. The presence of higher harmonics in the power supply can cause interference in electronic instruments. In this paper the values of the coefficients of THD and explicitly set them to values of the relevant standards.
EN
The centrifugal pumps, used for the intra-trade oil transportation are works on the gas saturated oil-water emulsions. The construction of pumps influences physical-chemistry and rheological properties of the transported emulsion, in flow area structural changes occur, dispersiveness and viscosity rise. The properties of emulsion, in turn influence pump specification, is reduced efficiency, increase the required power. New method of the analysis of pump specifications is proposed, solutions by increase of effectiveness in the work of pumps on emulsion given.
PL
Na podstawie badań eksploatacyjnych wybranych przepompowni melioracyjnych, eksploatowanych w systemach przeciwpowodziowych wyznaczono wskaźniki niezawodności stosowanych w nich agregatów pompowych. Uwzględniając specyfikę pracy przepompowni, przyjęto, że najodpowiedniejszą miarą oceny sprawności zestawu pompowego jest wskaźnik gotowości technicznej. Opracowano model pracy przepompowni i obliczono wartości liczbowe wskaźnika gotowości dla wybranej przepompowni.
EN
Based on running research of several pump-stations unfailingness indexes have been estimated for pumpsets used at the stations. Accordingly to running characteristics of the stations, technical readiness index has been chosen as the most representative estimator of performance. A model has been prepared that shows how the station works and values of readiness index have been calculated for selected station.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.