Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pulverised coal burner
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In pulverised coal (PC) burners that are most widespread in Poland an individual air excess ratio rules an amount of pollution generated, yet there is a lack of method that allows measurement of output parameters of a burner. It is therefore necessary to use indirect methods, which could primarily include acoustic, and optical methods. These methods are non-invasive and can provide virtually not delayed and additionally spatially selective information about the combustion process. Additional problems are generated biomass co-firing. The article shows application of relatively new class of classification methods – the artificial immunology algorithms to the combustion process diagnostics consisting in detection of incorrect air excess in PC burner.
PL
W palnikach pyłowych, które są najbardziej rozpowszechnione w Polsce współczynnik nadmiaru powietrza decyduje o ilości emitowanych zanieczyszczeń, jednak brak metodyumożliwiającej pomiar parametrów wyjściowych palnika. Konieczne jest więc stosowanie metod pośrednich, do których można zaliczyć przede wszystkim metody akustyczne i optyczne. Metody te są bezinwazyjne i pozwalają na otrzymanie praktycznie nieopóźnionej i dodatkowo selektywnej przestrzennie informacji o zachodzącym procesie spalania. Dodatkowe problemy powstają przy współspalaniu biomasy. Artykuł przedstawia zastosowanie stosunkowo nowej klasy metod klasyfikacji - sztuczne algorytmy immunologiczne do diagnostyki procesu spalania polegająca na wykrywaniu nieprawidłowejwartości nadmiaru powietrza palnika pyłowego.
EN
Recent technological changes in the Polish power industry have created opportunities for reducing NOx, CO, SO2 emissions, but - at the same time - created another operation problem: sulphur corrosion and erosion of boilers’ water-walls as well decreasing of the boiler’s efficiency. This has been the motivation for performing a detailed study of the air flow in low-NOx burners. A measuring stand was built inside a real medium power OP-230 boiler equipped with a low-NOx burner to measure the velocity field at the burner’s outlet and to prepare experimental characteristics of the burner. To extend the description, a numerical model of the burner was constructed and numerical calculations were executed by means of the Fluent program. Numerically calculated velocity profiles were compared with the results of measurements. The obtained results have been helpful in formulating recommendations to improve burner geometry.
PL
Obecne zmiany technologiczne w polskich elektrowniach i electrociepłowniach stworzyły szanse do redukcji emisji NOx, CO oraz SO2 ale jednocześnie przyczyniły się do powstania nowych problemów eksploatacyjnych takich jak np.: korozji siarkowej i erozji płaszczy kotłów jak i również obniżenia sprawności pracy kotłów. Powyższe problemy były motywacją do dogłębnej analizy przepływu powietrza w niskoemisyjnych palnikach wirowych. Stanowisko pomiarowe przeznaczone do wyznaczania pola prędkości uwylotu z palnika oraz charakterystyk pomiarowych palnika było stworzone w rzeczywistym kotle OP-230 wyposażonym w nisko emisyjny palnik. Do poszerzenia opisu zbudowano numeryczny model palnika, a obliczenia numeryczne były wykonane za pomocą pakietu oprogramowania o nazwie Fluent. Rezultaty tych obliczeń numerycznych były porównane z pomiarami. Otrzymanane wyniki były pomocne w tworzeniu wytycznych modernizacji palnika.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.