Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  puls
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Exploratory study on remote photoplethysmography using visible light cameras
EN
With visible light video cameras, it is possible to estimate the cardiac pulse, tracking the intensity changes in the image produced by the blood volume variations in the microvascular tissue. This estimation is provided by a measuring technique called remote photoplethysmography (RPPG). In this study we explore the data acquisition of the RPPG using standard video cameras used in personal computers.
PL
Za pomocą kamer wideo w świetle widzialnym można oszacować tętno serca, śledząc zmiany intensywności obrazu wytwarzanego przez zmiany objętości krwi w tkance mikronaczyniowej. Oszacowanie to zapewnia technika pomiarowa zwana fotopletyzmografią zdalną (RPPG). W tym badaniu badamy akwizycję danych z RPPG przy użyciu standardowych kamer wideo używanych w komputerach osobistych.
PL
Wstęp i cele: W pracy przedstawiono analizę saturacji, tętna i amplitudy fali tętna w pulsoksymetrii noworodków. Głównym celem pracy jest opracowanie porównania wartości saturacji i amplitudy, wartości tętna i amplitudy oraz wartości saturacji i tętna badanych noworodków. Materiał i metody: Materiał stanowiło odpowiednio 180 zdarzeń z grupy badanej oraz 90 zdarzeń z grupy kontrolnej (obrazy z monitora Infinity Vista XL). Zastosowano metodę analityczną, graficzną i statystyczną. W opracowaniu materiału wykorzystano programy Gateway Suite firmy Dräger Medical, Corel Photo-Paint oraz MS-Excel. Wyniki: W grupie badanej dla saturacji 40 - 100% jak i kontrolnej dla saturacji 88 - 100% spadkowi jej wartości towarzyszył istotny wzrost wartości amplitudy fali tętna oraz niewielki spadek wartości tętna. W grupie badanej dla tętna 84 - 196 bpm jak i kontrolnej dla tętna 104 - 182 bpm spadkowi jego wartości towarzyszył niewielki wzrost wartości amplitudy fali tętna. Wniosek: Spadkowi saturacji krwi (zwłaszcza poniżej 85%) towarzyszy wzrost amplitudy fali tętna. Zjawisko wzrostu amplitudy fali tętna wyprzedza o kilka sekund desaturację.
EN
Introduction and aims: The paper presents some analysis of saturation, pulse rate and pulse wave amplitude in neonates pulse oximetry. The main aim of the study is to elaborate a comparison of saturation and amplitude values, pulse rate and amplitude values and of saturation and pulse rate values of the neonates. Material and methods: The material constitutes 180 events in the study group and 90 events in the control group (images from the monitor Infinity Vista XL). The analysis, graphical and statistical methods have been used in the paper. In the study material have been used Gateway Suite of Dräger Medical Company, Corel Photo-Paint and MS-Excel programs. Results: In the study group for the saturation 40 - 100% and control group for saturation 88 - 100% its decrease values was accompanied by a significant amplitude values increase of the pulse wave and a slight decrease in heart pulse rate. In the study group for heart rate 84 - 196 bpm and control group pulse for 104 - 182 bpm its decrease value accompanied with a slight increase the amplitude values of the pulse wave. Conclusion: The decrease in blood oxygen saturation (especially less than 85%) is accompanied by an increase in the amplitude of the pulse wave. The phenomenon of pulse wave amplitude increase precedes desaturation by a few seconds.
PL
Wstęp i cele: W pracy przedstawiono analizę saturacji, tętna, amplitudy fali tętna i pola pod falą tętna w pulsoksymetrii noworodków. Głównym celem pracy jest opracowanie porównania wartości saturacji i amplitudy, wartości tętna i amplitudy oraz wartości saturacji i tętna badanych noworodków. Materiał i metody: Materiał stanowiło odpowiednio 180 zdarzeń z grupy badanej oraz 90 zdarzeń z grupy kontrolnej (obrazy z monitora Infinity Vista XL). Zastosowano metodę analityczną, graficzną i statystyczną. W opracowaniu materiału wykorzystano programy Gateway Suite firmy Dräger Medical, Corel Photo-Paint oraz MS-Excel. Wyniki: W grupach badanej i kontrolnej spadkowi wartości saturacji obserwowano istotny wzrost pola zawartego między falą tętna a osią odciętych. Pole zawarte między falą tętna a osią odciętych może być interpretowane z objętością przepływającej krwi w mikrokrążeniu. W obu grupach obserwowano wysoce statystyczną korelację pomiędzy wartościami amplitudy i pola pod falą tętna. Znajomość metody wyznaczania pola pod falą tętna, umożliwia przejście do obliczeń objętości przepływającej krwi w naczyniach obwodowych. Wniosek: Spadkowi saturacji krwi (zwłaszcza poniżej 85%) towarzyszy wzrost amplitudy fali tętna. Zjawisko wzrostu amplitudy fali tętna wyprzedza o kilka sekund desaturację.
EN
Introduction and aims: The paper presents some analysis of saturation, pulse rate, pulse wave amplitude and area under fulse wave in neonates pulse oximetry. The main aim of the study is to elaborate a comparison of saturation and amplitude values, pulse rate and amplitude values and of saturation and pulse rate values of the neonates. Material and methods: The material constitutes 180 events in the study group and 90 events in the control group (images from the monitor Infinity Vista XL). The analysis, graphical and statistical methods have been used in the paper. In the study material have been used Gateway Suite of Dräger Medical Company, Corel Photo-Paint and MS-Excel programs. Results: In the examined and control groups a decrease in saturation value was observed a significant increase in the field contained between the pulse wave and the abscissa axis. The area between the pulse wave and the abscissa axis can be interpreted as the volume of blood flowing in the microcirculation. In both groups a highly statistical correlation between the values of amplitude and field under the pulse wave was observed. Knowledge of the method of determining the area under the pulse wave allows you to go to calculations of the volume of blood flowing in peripheral vessels. Conclusion: The decrease in blood oxygen saturation (especially less than 85%) is accompanied by an increase in the amplitude of the pulse wave. The phenomenon of pulse wave amplitude increase precedes desaturation by a few seconds.
PL
Badanie miało na celu sprawdzenie możliwości wykorzystania technologii VR w celu wywołania konkretnych emocjiu badanego. Przeprowadzone badania literaturowe wykazały wysokie prawdopodobieństwo uzyskania pomyślnych wyników, jednak dotychczas badania opierane były na pomiarach uzyskanych przy użyciu wyspecjalizowanego, drogiego sprzętu. Niniejsza praca miała wykazać, że uzyskanie podobnych rezultatów jest możliwe również z wykorzystaniem budżetowych rozwiązań. Uzyskane wyniki pozwalają stwierdzić, że nawet korzystając z mało wyszukanych technologii można uzyskać zadowalające rezultaty, które mogą określić wpływ obrazu wyświetlanego w goglach na emocje badanego.
EN
The study was tend to checking the possibility of using VR technology to invoke specific emotions on the subject. Literature studies have shown a high probability of obtaining successful results, but so far studies have been based on measurements obtained using specialized, expensive equipment. This study was about to show that obtaining similar results is also possible with usage of low budget solutions. Received results allow to conclude even using the less sophisticated technology, satisfactory results can be gained, which can determine the effect of the image displayed in the goggles on the emotions of the subject.
PL
Artykuł prezentuje analizę wartości pulsu człowieka w sytuacji wysiłku fizycznego oraz odpoczynku z podziałem na dwie grupy wiekowe oraz płeć. Pomiary wykonano przy użyciu aplikacji mobilnej oraz ciśnieniomierza nadgarstkowego. Badano dokładność pomiaru telefonem względem ciśnieniomierza oraz istotność statystyczną różnic pomiędzy grupami wiekowymi, płcią oraz wykonywaną czynnością. Niedokładność pomiarowa waha się od 4 do 12 %. Aplikacja mobilna dokładnej odwzorowuje puls podczas odpoczynku.
EN
The paper presents the analysis of the human heartbeat value under the physical exercise and rest condition. The test group was divided into four groups regarding age and sex. Measurements were performed using a mobile application and a blood pressure monitor. The phone's accuracy with respect to the blood pressure gauge was measured and the statistical significance of differences between age groups, sex and activity was also computed. Measurement inaccuracy varies from 4 to 12%. The mobile application accurately reproduces the pulse during rest.
6
Content available remote Wyznaczanie zmienności rytmu serca na podstawie fali tętna
PL
W artykule przedstawiono metodę wyznaczania sygnału reprezentującego zmienność rytmu serca (ang. HRV) na podstawie fali tętna. Fala tętna dostarcza informacji o czasie trwania poszczególnych cykli pracy serca. Stanowi to podstawę do opracowania tachogramu, który jest następnie przekształcany zgodnie z powszechnie stosowanym modelem stymulatora kardiologicznego, tzw. całkowym, impulsowym modulatorem częstotliwości (ang. IPFM).
EN
In this paper, a method for heart rate variability (HRV) detection from the arterial pulse signal, based on the improved integral pulse frequency modulation (IPFM) model is presented.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.