The author addresses the problem of the superior’s authority and its importance in commanding subordinates in uniformed services. Based on the analysis of the source literature and his own experiences, he defines the concept of authority and interprets its types. In the context of reflections on the subject of authority, he also defines the concepts of command and leadership and indicates the positive consequences of liberating authority but also to the negative implications of authoritarian management of subordinates.
PL
Autor podejmuje problem dotyczący autorytetu przełożonego i jego znaczenia w dowodzeniu podwładnymi w służbach mundurowych. Na podstawie analizy literatury przedmiotu oraz własnych doświadczeń definiuje pojęcie autorytetu i interpretuje jego rodzaje. W kontekście rozważań o autorytecie wyjaśnia również pojęcia: dowodzenie i przewodzenie oraz wskazuje na pozytywne następstwa autorytetu wyzwalającego, ale także na negatywne implikacje autorytarnego kierowania podwładnymi.
Artykuł prezentuje wyniki analizy wpływu zawilgocenia cegły ceramicznej na współczynnik przewodzenia ciepła i wskazuje na problem, jakim jest oddziaływanie zawilgocenia przegród zewnętrznych na zmianę temperatury wewnętrznej powierzchni przegrody i wielkość strat ciepła. Wzrost stopnia zawilgocenia przegrody powoduje wzrost wartości współczynnika przenikania ciepła, co wpływa bezpośrednio na obniżenie temperatury wewnętrznej powierzchni ściany zewnętrznej i odczucia cieplne użytkowników budynków oraz na temperaturę operatywną. Dodatkowo w razie obniżenia temperatury powierzchni ściany poniżej temperatury punktu rosy występuje wykroplenie się wilgoci na powierzchni ściany, co przy braku prawidłowo działającej wentylacji prowadzi do rozwoju grzybów pleśniowych. Chcąc zapobiec wystąpieniu w analizowanym budynku negatywnych skutków niekorzystnego obniżenia temperatury przegrody, zaproponowano docieplenie ścian od zewnątrz. Po dociepleniu budynku konieczna jest modernizacja istniejącej instalacji grzewczej i dopasowanie jej do nowych, obniżonych wartości strat ciepła. Zaproponowano nowe wielkości grzejników oraz nowe źródło ciepła.
EN
The article presents the results of an analysis of the effect of moisture on the heat transfer coefficient of a clay brick, and points out the problem of how moisture in the building envelope affects the change in the temperature of the internal surface of the wall and the amount of heat loss. An increase in the amout of moisture content of the building material results in a higher value of the thermal conductivity coefficient, which causes an increase in the heat transfer coefficient and thus also in the transmission heat loss of the building. A higher value of heat transfer coefficient has a direct effect on lowering the temperature of the inner surface of the exterior wall, which has a significant impact on the thermal sensations of building occupants by affecting the operative temperature. In addition, when the wall surface temperatureis lower than the dew point temperature, moisture condensation occurs on the wall surface, which, in the absence of properly functioning ventilation, leads to the development of mold. In order to prevent the occurrence in the analyzed building of the negative effects of an unfavorable decrease in the temperature of the partition, it was proposed to insulate the walls from the outside. After insulating the walls, it is necessary to modernize the existing installation and adjust it to the new reduced heat loss values of the building. New radiator sizes and a new heat source have been proposed.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This article aimed to study the characteristics and mechanisms of 3D heat transfer through clothing involving the air gap. A three-dimensional finite volume method is used to obtain the coupled conductive, convective, and radiative heat transfer in a body-air-cloth microclimate system. The flow contours and characteristics of temperature, heat flux, and velocity have been obtained. The reason for the high flux and temperature regions was analyzed. Computational results show that the coupled effect of the air gap and the airflow between the skin and garment strongly influences the temperature and heat flux distribution. There are several high-temperature regions on the clothing and high heat flux regions on the body skin because the conductive heat flux can cross through the narrow air gap and reach the cloth surface easily. The high-speed cooling airflow brings about high forced convective heat flux, which will result in the temperature increase on the upper cloth surface. The radiative heat flux has a strong correlation with the temperature gradient between the body and clothing. But its proportion in the total heat flux is relatively small.
The authors of this article deal with questions concerning command and/or leadership in military service conditions. Based on the analysis of the reference literature and their own reflections, they define the notions of command and leadership, pointing to differences and similarities. In addition, they try to answer the questions of whether students of military universities are being educated towards leadership or to become leaders? And, whether in the practice of military service, we encounter command or leadership, and why?
PL
Autorzy w artykule podejmują kwestie dotyczące dowodzenia i/lub przewodzenia w warunkach służby wojskowej. Na podstawie analizy literatury przedmiotu oraz własnych refleksji definiują pojęcie dowodzenia i przewodzenia, wskazując na różnice i podobieństwa. Ponadto podejmują próbę odpowiedzi na pytania, czy w uczelniach wojskowych kształci się przywódców, czy w kierunku przywództwa? Oraz, czy w praktyce służby wojskowej spotykamy się z dowodzeniem, czy przewodzeniem i dlaczego?
W artykule obliczone zostały zmiany długości i prędkości rozchodzenia się fali elektromagnetycznej w.cz. z wybranego przedziału częstotliwości po przejściu z powietrza do ciała człowieka. Obliczono również umowną głębokość wnikania fali. Autorzy zajmujący się tą problematyką przyjmują, że ciało jest środowiskiem dobrze przewodzącym. W niniejszym opracowaniu dokonano również obliczeń przy założeniu, że ciało dla pewnych częstotliwości przedstawia sobą środowisko słabo przewodzące. Dla takiego założenia ważny parametr jakim jest głębokość wnikania fali wykazuje znacznie większą wartość niż przy przyjęciu, że jest ono dobrym przewodnikiem.
EN
In a very large number of publications dealing with the influence of the HF electromagnetic field upon the human body, the conventional depth of wave penetration into the body (Fig. 2)is calculated. However, any changes in the parameters of the wave (its length and the speed of its propagation) in a new environment are not taken into account. While calculating the conventional depth of penetration, the authors assume that the human body is a well conducting medium. In the presented paper the author has computed the depth the wave penetration into the body making use of the dependences obligatory both for a feebly and well conducting media. The criterion, similar to that used in technology, i.e., the relation of the conduction currents to the dielectric displacement ones, has been deployed. It is established that for the frequencies above 0,5 GHz the human body ought to be treated as a feebly conducting medium. The changes in the parameters of the body and the above–mentioned coefficient are included in the item [8] in the literature. Subsequently, the charges in the wavelengths and the speeds of wave propagation in the body have been calculated assuming that it is both a feebly and well conducting medium (Figs. 5, 6, 7 and 8). By accepting the body as a good conductor it is possible to observe a much smaller depth of wave penetration than in the case of assuming that it is a poor conductor. The considerable differences are also noticed while the wavelengths and speed of wave penetration are being calculated. While computing it is necessary to determine strictly in what kind of environment the wave is going to propagate depending on the frequency and parameters of the body.
In this paper, we study the onset of cellular convection in a horizontal fluid layer heated from below, with a free-slip boundary condition at the bottom when the driving mechanism is surface tension at the upper free surface, in the light of the modified analysis of Banerjee et al. (Jour. Math. & Phys. Sci., 1983, 17, 603). This leads to a formulation of the problem which depends upon whether the liquid layer is relatively hotter or cooler. It is found that the phenomenon of surface tension driven instability problems should not only depend upon the Marangoni number which is proportional to the maintained temperature differences across the layer but also upon another parameter that arises due to variation in the specific heat at constant volume on account of the variations in temperature. Numerical results are obtained for the problem wherein the lower free boundary is perfectly thermally conducting.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł składa się z czterech części. W całości zawiera uzasadnienie, że dowodzenie, stosowane w organizacjach zhierarchizowanych, jest immanentną częścią zarządzania. Treści wywodu są poprzedzone wprowadzeniem wskazującym na niedostatki w zarządzaniu. Dwie kolejne części (druga i trzecia) zawierają argumentację przemawiającą za potrzebą uwzględniania dowodzenia w ogólnej teorii zarządzania. Całość zamyka krótkie zakończenie, nawiązujące do istoty problemu oraz bibliografia.
EN
This article consists of four parts. In its entirety, it includes justification for the fact that command, used in hierarchical organizations is an immanent part of management. The contents are preceded by introduction pointing to deficiencies in management. Two following parts (the second and the third) contain arguments for the need of considering command in the general theory of management. The whole concludes with a short ending referring to the essence of the problem and bibliography.
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The thermal property of fabric is very important for both its thermal comfort and protection against challenging weather conditions. Although some research has reportedly been done on the dimensional and some of the mechanical properties of rib knit fabrics, no detailed study about the thermal properties of rib knit fabric could be seen. In this study, the natural and forced convective heat transfer characteristics of rib knit fabric have been analysed. The effect of rib design and other fabric properties such as fabric density and air permeability on thermal behaviour have been considered. It has been noted that a decrease in rib number of the order of 3×3, 2×2 or 1×1 leads to a decrease in heat loss due to an increase in the amount of air entrapped between the face and the back loop. The results also indicated that as the fabric gets tighter, so the heat loss lessens, due to reduced air permeability, i.e., reduced air circulation within the fabric. Thus, it results that when the fabric design (1×1 rib, 2×2 rib, 3×3 rib, etc.) is taken into consideration, the conductive heat loss due to fibres and air gaps becomes more important than the heat loss due to air circulation (convective heat loss). However, when the fabric density for each fabric design is taken into consideration, the heat loss due to air circulation (convective heat loss) becomes more important than the conductive heat loss due to fibres and air gaps.
PL
Właściwości termiczne płaskich wyrobów włókienniczych są bardzo ważne z punktu widzenia komfortu i zabezpieczenia przed warunkami pogodowymi. Jakkolwiek istnieją publikacje o właściwościach mechanicznych i deformacjach dzianin dwuprawych, to nie natrafiono na informacje dotyczące ich właściwości termicznych. Autorzy przeprowadzili badania przebiegu przenoszenia ciepła za pośrednictwem naturalnej i wymuszonej konwekcji. Badano wpływ splotu, gęstości dzianiny i jej przepuszczalności dla powietrza na właściwości termiczne. Stwierdzono, że zmniejszenie rządków oczek dwuprawych z 3x3 do 1x1 prowadzi do zmniejszenia strat cieplnych w wyniku wzrostu ilości powietrza zamkniętego pomiędzy czołem a tylną ścianą oczka. Podobnie wzrost gęstości dzianiny zmniejsza straty ciepła w wyniku zmniejszenia przepuszczalności powietrza (zredukowanej cyrkulacji powietrza w obrębie dzianiny). Biorąc pod uwagę wzór dzianiny (sploty dwuprawe 1x1, 2x2, 3x3, itd.), to straty ciepła na przewodzenie poprzez włókna i szczeliny powietrza są bardziej istotne niż straty ciepła w wyniku cyrkulacji powietrza (konwekcji). Natomiast, jeżeli weźmiemy pod uwagę gęstość dzianiny dla danego wzoru, to straty konwekcyjne są znaczniejsze niż straty na przewodzenie.
The standard textbook treatment of the conduction in a semiconductor diode as a diffusion current is only correct for diodes and the junctions of bipolar transistors if they have a very high quality. The presence of shallow or deep donors or acceptors affects the size of the depletion width and the size of the diffusion current but the qualitative form of the current remains. However, mid gap generation-recombination (g-r) levels in the depletion region give rise to a g-r current which is apparent at low voltages. At high currents there is also a decrease in the expected current because of the voltage dropped across the resistance of the semiconductor material between the terminals and the diode itself. Of particular interest here, the current in a diode with a very high concentration of g-r centres is very different. It is shown that this is Ohmic with a resistance depending on the dimensions and the intrinsic semiconductor properties and not on the properties of the junction itself. This analysis with Ohmic characteristic and mid gap Fermi level pinning may not have been appreciated in bipolar or Schottky diodes and Ohmic contacts made with high resistance, irradiated and semi-insulating materials.
PL
Typowy opis mechanizmu przewodzenia diod półprzewodnikowych polegający na przepływie prądu dyfuzyjnego jest poprawny jedynie dla diod i złączy tranzystorów bipolarnych o wysokiej jakości. Obecność donorów bądź akceptorów powierzchniowych lub położonych głębiej wpływa na szerokość warstwy zubożonej i tym samym na wielkość prądu dyfuzyjnego, aczkolwiek charakter prądu pozostaje taki sam. Jednakże poziomy generacyjno-rekombinacyjne, usytuowane w środku pasma zabronionego w warstwie zubożonej powodują powstanie prądu g-r uwidaczniającego się przy małych napięciach. Przy dużych prądach występuje także spadek oczekiwanej wartości prądu wskutek spadku napięcia na rezystancji materiału półprzewodnikowego pomiędzy wyprowadzeniami a samą diodą. Prąd diody o bardzo dużej koncentracji centrów generacyjno – rekombinacyjnych jest bardzo różny. Wykazano, że ma on charakter omowy (liniowy) z rezystancją zależną od rozmiarów i właściwości półprzewodnika a nie od właściwości samego złącza. Analiza zakładająca charakterystykę omową i poziom Fermiego usytuowany w środku warstwy zabronionej może jednakże nie być adekwatna dla diod bipolarnych i Schottkiego o kontaktach omowych wykonanych z materiałów o dużej rezystancji, napromieniowanych i półizolacyjnych.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The present paper is devoted to identification of the material phases location for one-dimensional structure with respect to the first-order sensitivity of the identification functional. A transient heat conduction problem within a thermal anisotropic one-dimensional structure is formulated. The material derivative concept and both the direct and adjoint approaches are used in considering the shape identification of the problem domain. The identification functional is assumed in the form of the "distance" between the temperature of the identified body and the measured temperature of real structure. Stationarity conditions are formulated with respect to the obtained first-order sensitivities. Numerical examples of internal boundary identification are presented.
Przedstawiono wyniki badań przewodnictwa cieplnego tego samego materiału (płytki epoksydowo-szklanej laminowanej dwustronnie miedzią), przeprowadzonych niezależnie trzema metodami na trzech różnych stanowiskach badawczych. Aparat płytowy z wewnętrznym grzejnikiem, obwodową ochronną płytą cieplną, stanowiącą przeciwgrzałkę i dwiema chłodnicami. Płytki badane, układane w stosy umieszczono nad i pod płytą grzejną a chłodnicami (do 4 płytek) lub w tylko nad płytą (od 6 do 8 płytek). Płytki w celu przeciwdziałania oporowi kontaktowemu smarowano pastą silikonową f-my DOW CORNING (USA). Aparat dwu-płytowy do wyznaczania krzywych nagrzewania. Płytki badane umieszczono pomiędzy dwiema płytami: jedną nagrzewaną, a drugą odbierającą strumień ciepła. Na podstawie obróbki numerycznej uzyskanych krzywych nagrzewania określano współczynnik przewodzenia ciepła. Opór kontaktowy wyznaczono przekładając płytki folią komorową polietylenową, o zwiększanej po każdej serii pomiarów, liczbie otworów. Aproksymacja dla przypadku, gdy pomiędzy płytkami nie będzie już folii, eleminuje błąd oporu kontaktowego. Aparat z dwiema płytami pomiarowymi do pomiaru rzeczywistego strumienia ciepła przechodzącego z płyty grzanej do chłodnicy. Opór kontaktowy wyeliminowano umieszczając płytkę badaną w wodzie o znanej grubości i wyznaczonym dla warunków pomiaru współczynniku przewodzenia ciepła. Przeciwny do kierunku sił grawitacji kierunek strumienia ciepła wykluczał powstawanie konwekcji wewnątrz warstewek wody.
EN
Results of measurement of heat conduction coefficient obtained independently in three experimental stands of various construction have been presented. Three different investigation methods were also used. All results obtained were performed to the same tested material epoxy-glass laminate, covered double-side cooper.
W pracy przedstawiono wyniki obliczeń własnych, dotyczące wielkości cieplnych, występujących w początkowym, bardzo krótkim okresie bezpośredniego kontaktu dwóch różnych ciał ciekłych: tzw. 'paliwa' i 'chłodziwa', o znacznie różniących się temperaturach początkowych (jednowymiarowe zagadnienie nieustalonego przewodzenia ciepła z warunkiem brzegowym IV rodzaju na powierzchni stykowej). Rozpatruje się kilka zestawień materiałowych paliwo-chłodziwo w trzech zasadniczych konfiguracjach geometrycznie regularnych (konfiguracji płytowej P, cylindrycznej C oraz kulowej K). Przeprowadzono obliczenia dla różnych geometrii i różnych parametrów M charakteryzujących wymieszane masy paliwa i chłodziwa. Użyto zarówno metodę bilansów elementarnych (realizowaną w dokumentach komputerowych systemu MathCAD6 PLUS) jak i istniejące rozwiązania dokładne zadań stykowych (przy pewnych założeniach upraszczających). Rozpatrywane przedziały czasowe są na tyle krótkie, że nie stwarzają możliwości rozwoju konwekcyjnych form transportu energii. Wnioski z obliczeń są zorientowane głównie na wytypowanie układu i zestawu generującego potencjalnie największą dynamikę zmian objętościowych. Analizuje się następujące cztery zestawienia substancji: ciekły dwutlenek uranu - ciekły sód; woda - ciekły azot; ciekłe aluminium - woda, lawa - woda.
EN
Paper present results of own calculation, related to thermal quantities, occurring in the early stage of direct contact of two liquids, 'fuel' and 'coolant', having significantly different temperatures. It is unsteady, one-dimensional heat conduction problem, with boundary condition of the IV=type. Three different fuel fragmentation geometry, in the coolant, were considered: slab, cylindrical and spherical. Calculations were carried out for wide ranges of parameter values, characterising 'fuel-coolant' mixtures. The method of finite volume balances (utilising MathCAD6 PLUS program) and theoretical solution for the initial temperature were used. The time scale involved in this analysis was sufficiently short, to prevent other but conduction form of heat transfer. Calculations were oriented towards system selection, generating potentially the highest deposition of energy in the coolant. Four different liquid mixture were analysed: molten uranium dioxide-liquid sodium, water liquid nitrogen, molten aluminium-water and lava-water.