Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  przewód odgromowy
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The development of a mathematical model of a three-phase ultrahigh voltage transmission line with two overhead ground wires is presented in the paper. The mathematical model is based on differential equations of state of a long line with partial derivatives in the matrix-vector form. The boundary conditions of the second kind (Neumann's conditions) are used, which enables obtaining functions of unknown coordinates of the overhead ground wires mode at the beginning and at the end of the voltage transmission line to solve the transmission line equation. Some results of computer simulations of transients during switching on and a single-phase short circuit of the line are presented in the form of corresponding graphic functions of its mode coordinates.
PL
W artykule przedstawiono model matematyczny trójfazowej linii elektroenergetycznej ultra wysokiego napięcia z dwoma przewodami odgromowymi. Model matematyczny wykorzystuje równania różniczkowe o pochodnych cząstkowych elektromagnetycznej długiej linii w postaci macierzowo-wektorowej. Jako warunki brzegowe wykorzystano warunki drugiego rodzaju (warunki Neumanna), co z kolei pozwoliło obliczyć przebiegi napięcia i prądu na początku i na końcu linii elektroenergetycznej. Wyniki symulacji komputerowej stanów nieustalonych podczas załączania linii oraz zwarcia jednofazowego w jej końcu przedstawiono w postaci rysunków.
PL
W Polsce przewody fazowe linii wysokich napięć chroni się przed bezpośrednimi uderzeniami piorunów za pomocą przewodów odgromowych. Uznano, że linie średnich i niskich napięć nie opłaca się chronić przewodami odgromowymi. Od tej obowiązującej w naszym kraju zasady istnieją bardzo nieliczne wyjątki.
PL
Falowe lokalizatory (LF) umacniają swoją popularność na rynku urządzeń służących do szybkiego i dokładnego określania miejsca uszkodzenia linii elektroenergetycznych. Charakteryzują się sprawdzoną w warunkach rzeczywistych dokładnością lokalizacji w zakresie pojedynczego przęsła linii. Wysyłając ekipę serwisową do naprawy uszkodzonej w wyniku zwarcia linii, dyspozytor powinien mieć możliwość łatwego i dokładnego przekształcania wskazań LF w jednostkach względnych (p.u.) odniesionych do długości linii na rzeczywiste położenie słupa leżącego najbliżej miejsca zwarcia, jeśli chce zachować dokładność wskazań lokalizatora. Taka konwersja powinna zapewnić w rzeczywistych warunkach dokładność w zakresie jednego przęsła linii. W artykule przedstawiono kilka praktycznych metod służących do poprawy dokładności oceny rozpatrywanej odległości na podstawie uzyskanych pomiarów przez LF. Pierwsza metoda polega na wyznaczeniu określonego punktu w linii (słupa), który jest punktem odniesienia, wyznaczonym na podstawie określenia fizycznego miejsca zwarcia w linii i związania go ze wskazaniami LF w jednostkach względnych. Położenie takiego punktu w terenie może zwiększyć dokładność wyznaczenia innych zwarć w linii na podstawie wskazań LF. Druga metoda polega na wykorzystaniu danych uzyskanych na podstawie protokołów uruchomienia lub diagnostyki kabli światłowodowych umieszczonych w przewodach odgromowych linii. Podczas takich czynności firmy instalacyjne mogą zmierzyć straty wzdłuż światłowodu za pomocą optycznych reflektometrów (OTDR - Optical Time-Domain Reflectometry). Na podstawie analizy zmian w jednorodności światłowodu, pomiary te umożliwiają identyfikację słupów, na których są łączone odcinki światłowodu (spawanie). Zidentyfikowane w ten sposób słupy występują następnie w charakterze wspomnianych punktów odniesienia.
EN
Traveling-wave (TW) fault locators continue to gain popularity as new economical fault-locating solutions enter the market. These fault locators have a field-proven potential for accuracy on the order of one tower span. When dispatching line crews to inspect and repair the line after a fault, utilities need a simple and accurate method of converting the per-unit fault location from the TW fault locator into a tower position in the physical world if they want to retain the inherent per-unit fault-locating accuracy. This paper presents several practical methods for improving the dispatch accuracy. One method uses line faults for which line crews confirmed the fault location with confidence. The method maps a tower with a confirmed fault to the per-unit location of the fault. Such a tower becomes a landmark to help map other towers with improved accuracy. Another method uses a commissioning or troubleshooting report for the fiber-optic cable in the ground wire of the line. As a part of commissioning or troubleshooting fiber cables, utilities measure losses using Optical Time-Domain Reflectometry (OTDR). The OTDR measurements allow locating towers with splices. In our method, these towers become landmarks to map other towers with accuracy.
PL
Stosowanie rozwiązań katalogowych w odniesieniu do słupów linii 110 kV ma w Polsce długą tradycję. Już w latach 70. powszechne stało się stosowanie słupów serii stypizowanych. Aktualnie proponowane przez ENERGOPROJEKT-KRAKÓW SA rozwiązania projektowe dla linii jednotorowych seria EJ24 i dla linii dwutorowych ED24, bazujące na wieloletnich doświadczeniach wspólnego projektowania słupów i fundamentów, pozwalają na optymalizację projektów linii elektroenergetycznych zgodnie z obowiązującymi normami.
EN
Application of catalogue solutions with respect to 110 kV power line pillars has had a long tradition in Poland. It became a common practice already in the 1970s to use identical pillars produced in series. The currently proposed by ENERGOPROJEKT-KRAKÓW SA design solutions for single circuit lines of series EJ24 and double circuit ED24 lines, basing on many years of experience in collective designing of pillars and foundations, make it possible to optimize the designing process of power lines in accordance with the current standards.
PL
W artykule przedstawiono nowatorską metodę obliczania wartości prądów płynących w przewodach odgromowych linii elektroenergetycznych w czasie zwarć. Metoda może być stosowana dla złożonych układów sieciowych, składających się z kilku stacji oraz różnych typów linii. Analizowane mogą być linie jedno- i dwutorowe z jednym bądź dwoma przewodami odgromowymi. Metoda pozwala na dobór przewodów odgromowych pod względem wytrzymałości cieplnej z mniejszym ryzykiem niepewności niż powszechnie stosowane metody. Prezentowana metoda obliczeniowa pozwala również na ocenę ochrony przeciwporażeniowej linii, poprzez wyznaczenie wartości prądów płynących w uziomach słupów.
EN
The paper presents a new method for calculating of currents in the earth wires during a phase to earth fault. The method can be used for analysis of power system that consists a several number of substations and transmission lines of different types. It can be used for analysis of single and double circuit overhead transmission lines with one or two earth wires. The method allows for earth wire thermal rating selection with lower level of uncertainty compared to the existing calculation methods. Additionally it allows for evaluation of shock hazards by calculating earthing currents and voltages for every tower of the line.
7
Content available remote Lightning Performance of MV Underground Cables with Shield Wire
EN
Lightning protection of medium voltage underground cables is studied in this paper. Simulation of an underground cable with a shield wire is made to investigate protection against lightning discharges around the cable. The performance of the protection scheme is investigated with the Finite Element Method (FEM) considering different soil structures and resistivities. Finally, the failure rates of the underground cable with and without a shield wire are compared based on the real lightning statistics in Finland. It is expected that the results will further understanding of the need for lightning protection on medium voltage underground cables.
PL
W artykule podjęto próbę określenia zagrożenia piorunowego ułożonych w ziemi kabli średniego napięcia z przewodem odgromowym. Wykorzystano metodę elementów skończonych w celu doboru odpowiednich sposobów ochrony kabli przed wyładowaniami piorunowymi. Wyznaczono wskaźnik awaryjności podziemnych kabli z lub bez przewodu odgromowego. Wykorzystano do tego celu dane statystyczne zebrane z terenu Finlandii.