EN
Electrical transients in high-order resonant power converters are difficult to solve with classical analytic analysis. It is also costly and challenging to verify some phenomena empirically. Thus, design and analysis of electronic circuits can be remarkably improved by using appropriate simulation tools, especially in the field of power electronics. In our work, a complete simulation of digitally controlled 350W LLC resonant power converter is presented. Ngspice was utilized as a simulator and KiCad was used as applicative schematic editor. In particular, the use of simplified element models in time domain analysis provide short simulation time. We achieved good consistency between simulation results and hardware measurements. The introduced simulation environment with the LLC converter model is a compelling tool that shortens design time and reduces deployment costs. Among many published scientific papers, this work is distinguished by the fact that the simulation includes a converter with full resonant circuit, quality factor limiter and digital feedback loop.
PL
Stany przejściowe w przetwornicach rezonansowych są trudne do wyznaczenia analitycznie. Również pomiary z wykorzystaniem modeli fizycznych są bardzo czasochłonne oraz wymagają specjalistycznego sprzętu. Jednak gdy wykorzysta się narzędzia symulacyjne proces analizy i projektowania układów energoelektronicznych ulega znacznemu usprawnieniu. W artykule przedstawiono wyniki symulacji sterowanej cyfrowo przetwornicy rezonansowej typu LLC o mocy 350W. W symulacjach wykorzystano oprogramowanie Ngspice, a jako edytor schematów KiCad. Aby otrzymać krótkie czasy symulacji i móc przeprowadzić badania kompletnej przetwornicy wykorzystano uproszczone modele podzespołów. W pracy otrzymano dobrą zgodność wyników symulacji i pomiarów. Zaprezentowany model symulacyjny wraz z narzędziami tworzy kompletne środowisko, które pozwala skrócić czas projektowania i testowania cyfrowych zasilaczy. Wyróżnikiem przedstawionego podejścia jest połączenie analogowej symulacji przetwornicy rezonansowej wraz z implementacją w pełni cyfrowego regulatora.
PL
W artykule przedstawiono układy pomiarowe zastosowane w generatorze do nagrzewania indukcyjnego. Omówiono ich budowę oraz sposób dołączenia do systemu sterowania falownikiem napięcia. Przedstawiono również wymagania stawiane tym układom przez algorytmy wyznaczające parametry obciążenia i moc wydzielaną w generatorze.
EN
The paper describes measurement systems used in induction heating generator. Their build and connecting to the control system of voltage converter had been presented. The requirements resulting from algorithms which calculate load parameters and power absorbed by the load had been shown.
3
Content available remote System zasilania głowic atomizacyjnych do wytwarzania elektro-aerozoli
PL
W pracy przedstawiono problematykę wysokonapięciowego zasilania układu do elektryzacji indukcyjnej cząstek aerozoli wytwarzanych w głowicach z naddźwiękowym rozpraszaniem pneumatycznym w dyszy de Lavala. Do zasilania elektrod indukcyjnych głowic zastosowano indywidualne zasilacze wysokiego napięcia stałego małej mocy, pracujące w układzie rezonansowych przetwornic dc-dc. Zasilacze zamontowano na belce prototypowego, elektro-aerozolowego opryskiwacza agrotechnicznego bezpośrednio przy głowicach w celu ograniczenia do minimum połączeń w obwodzie WN. System zasilania wysokonapięciowego wyposażono w zdalny układ sterujący oraz opto-akustyczny sygnalizator stanu systemu wielogłowicowego. W pracy przedstawiono właściwości typowego zasilacza małej mocy oraz zwrócono uwagę na problematykę zagrożeń porażeniowych, jakie mogą wystąpić w warunkach awaryjnych. Oszacowano energię gromadzoną w układzie powielacza wysokiego napięcia, która może być rozproszona w warunkach niekontrolowanego rozładowania lub zwarcia, np. przez ciało człowieka.
EN
The paper discuses problems related to HV supply system for induction charging of aerosol droplets generated in supersonic pneumatic atomizing heads fitted with de Laval nozzle. Individual low power DC HV supply units, configured as resonant DC-DC converters, are applied for induction electrode charging. Supply units are installed on a drag-bar of prototype electro-aerosol agricultural spraying machine directly next to atomizing heads in order to minimize HV wiring length. The HV supply system is fitted with remote unit and opto-acoustic indicator for multi-head system state control. Operational characteristics of a standard HV low-power supply unit are presented and attention is drawn to problems related to electric shock hazards, which may arise in case of HV supply failure. Energy accumulated in HV multiplier subsystem, which may be discharged in case of any uncontrolled shorting (e.g. involving human body), is also assessed.
4
Content available remote Modern grid-connected photovoltaic power system with energy storage element
EN
In the article photovoltaic (PV) power systems are described. Power generated from renewable energy sources is not stable because of the energy fluctuations caused mainly by atmospheric conditions. Therefore, in order to improve the parameters and stability of the power system, PV power plants should cooperate with electrical energy storage system such as electrochemical batteries. Moreover, because of the reason that PV power plants are often located on the terrain which is accessible by the man, galvanic isolation may be obligatory. Since the efficiency of the power conversion in PV power systems has to be maximized soft switched resonant power converters, in which switching losses are minimized, are utilized in such PV power systems. Moreover, grid-connected PV inverter which is a crucial element of the PV power system is presented in the article.
PL
W artykule opisane są fototowoltaiczne systemy zasilania połączone z systemem elektroenergetycznym. Moc generowana z odnawialnych źródeł energii jest niestabilna, gdyż wpływają na nią warunki atmosferyczne. Jednakże, współpraca elektrownii słonecznych z układami magazynowania energii (np. bateriami elektrochemicznymi) istotnie poprawia parametry pracy i stabilność systemu elektroenergetycznego. Ponadto, elektrownie słoneczne często pracują w miejscach dostępnych dla człowieka, co wymaga stosowania izolacji galwanicznej ogniw od systemu elektroenergetycznego. Ze względu na konieczność utrzymania wysokiej sprawności przetwarzania energii w elektrowniach fotowoltaicznych, do konwersji energii wykorzystywane są rezonansowe przekształtniki energoelektroniczne o bardzo niskich stratach energii. Istotnym elementem systemu jest także przekształtnik sieciowy, który przekazuje energię z ogniw fotowoltaicznych do sieci.
PL
Artykuł przedstawia strukturę systemu zasilania zastosowanego w układzie anteny aktywnej z modułami półprzewodnikowymi na pasmo S. Głównym elementem systemu zasilania jest przetwornica rezonansowa dużej mocy o napięciu wyjściowym 36 V podzielona funkcjonalnie na: umieszczony w antenie zespół transformatora wyjściowego i znajdujący się poza anteną blok falownika mocy. Napięcie 36 V do zasilania części nadawczej jest dostarczone do modułów za pośrednictwem układu rozprowadzenia zasilania zawierającego dwie pary szyn zasilających moduły w lewej i prawej części kabiny. Wszystkie napięcia pomocnicze w kabinie są wytwarzane z 27 V, których dostarcza zewnętrzny zasilacz wyposażony w bateryjne podtrzymanie napięcia. W kabinie antenowej znajduje się również tablica rozdziału zasilania z zespołem włączników instalacyjnych realizujących funkcje zabezpieczeń nadprądowych dla poszczególnych obwodów.
EN
This paper presents structure of the power supply system used in S-band active antena unit with solid-state transmitter based on T/R modules. Main part of the power supply system is high power supplier with resonance circuit with the output voltage 36 V. The supplier is divided in two parts: power transformer unit which is mounted in the antenna cabin and resonance converter unit placed outside the antenna. 36 V for transmitter part is delivered to the modules through distribution system which includes two pairs of DC power buses supplying modules on the left and right sides of antenna cabin. Ali voltages in the antenna unit are delivered from DC/DC converters supplied from 27 V, which comes from external supplier equipped with battery support. There is also power supply 27 V distribution box in the antenna unit with the set of installation switchs which realize overcurrent protection function for different circuits.
PL
Przedstawiono schemat, zasadę działania oraz parametry zasilacza lasera ciałostałego z płynną regulacją czasu trwania impulsu wyjściowego. Opisano sposób działania podzespołów urządzenia. Dokonano analizy działania przetwornicy rezonansowej z symetrycznym podwajaczem napięcia i określono warunki jej poprawnej pracy. Zamieszczono też wyniki badań części energetycznej zasilacza i obliczono energię i moc impulsów pompujących.
EN
A circuit diagram, operation basics are presented and the parameters of supplier for solid state laser with continuous regulation of output pulse duration are given. The operation od sub-assemblies of the device is described. The analysis of operation of the resonance transducer with symmetric voltage doubler has been performed and its correct operation condidtions have been defined. The study results of the energetic part of the supplier arealso presented and energy as well as power of pumping pulses have been calculated.