Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  przeskok
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Cloud computing provides centralized computing services to the user on demand. Despite this sophisticated service, it suffers from single-point failure, which blocks the entire system. Many security operations consider this single-point failure, which demands alternate security solutions to the aforesaid problem. Blockchain technology provides a corrective measure to a single-point failure with the decentralized operation. The devices communicating in the cloud environment range from small IoT devices to large cloud data storage. The nodes should be effectively authenticated in a blockchain environment. Mutual authentication is time-efficient when the network is small. However, as the network scales, authentication is less time-efficient, and dynamic scalability is not possible with smart contract-based authentication. To address this issue, the blockchain node runs the skip graph algorithm to retrieve the registered node. The skip graph algorithm possesses scalability and decentralized nature, and retrieves a node by finding the longest prefix matching. The worst time complexity is O(log n) for maximum n nodes. This method ensures fast nodal retrieval in the mutual authentication process. The proposed search by name id algorithm through skip graph is efficient compared with the state-of-art existing work and the performance is also good compared with the existing work where the latency is reduced by 30–80%, and the power consumption is reduced by 32–50% compared to other considered approaches.
2
Content available remote Głogów pollution test station, a review of 30-years research
EN
Insulators made of different materials were tested: porcelain, glass, hydrophobic glazes, silicone rubber, hydrophobic epoxy resin and polymer concrete. Special attention was paid for tests of insulators that have a different specific leakage distance. The leakage current and flashovers were monitored and the degree of pollution on the insulator surfaces was sampled on different insulators with the same profile but made of different materials. It was found that a shorter specific leakage distance than that recommended by the IEC 60815 standard is possible.
PL
Testowano izolatory wyprodukowane z różnych materiałów: z porcelany, szkła, szkliw półprzewodzących, kauczuku silikonowego, żywicy epoksydowej, i betonu polimerowego. Szczególną uwagę poświęcono próbom izolatorów mających różną drogę upływu. Rejestrowano prąd upływu i przeskoki oraz wyznaczano ESDD na izolatorach o tym samym profilu lecz wykonanych z różnych materiałów. Wykazano, że jednostkowa droga upływu może być krótsza niż ta zalecana przez normę IEC 60815.
3
Content available remote Anomalous leakage currents on silicone rubber hollow insulators
EN
Leakage currents on silicone and porcelain housings were measured at a 110 kV substation (site pollution severity class heavy) for 7 months. Both types of housing had a similar geometry. The current on porcelain housings is usually up to 4,7 times higher than on silicone housings. However, significantly smaller currents (up to 2,6 times) were recorded on the porcelain insulators over a period of 8 days. Similar rare behavior was earlier seen at Glogow pollution test station and at Koeberg pollution test station on porcelain and silicone insulators with the same profiles. A better washability of porcelain during stronger rains plays a very important role in this phenomenon. It was shown that small leakage currents, usually in the range 4 -10 mA, cause surface erosion of silicone rubber housings.
PL
Przez 7 miesięcy mierzono prąd upływu na osłonach silikonowych I porcelanowych na rozdzielni 110 kV znajdującej się w III strefie zabrudzeniowej). Osłony miały podobny kształt. Prąd na osłonie porcelanowej był zazwyczaj większy niż na osłonie silikonowej (do 4,7 razy). Jednakże w ciągu 8 dni prąd na osłonie porcelanowej był mniejszy (do 2, 6 razy). Podobne takie rzadkie przypadki zauważono wcześniej na stacjach zabrudzeniowych w Koeberg i w Hucie Głogów na izolatorach o identycznym kształcie. Bardzo ważną rolę w tym zjawisku odgrywa lepsze oczyszczanie porcelany przez silniejsze deszcze. Wykazano, że niewielkie prądy upływu rzędu 4 –10 mA powodują erozję powierzchniową osłon silikonowych.
EN
This paper describes a methodology that was developed for the prediction of the critical flashover voltage of polluted insulators under sec and rain conditions least squares support vector machines (LS-SVM) optimization. The methodology uses as input variable characteristics of the insulator such as diameter, height, creepage distance, and the number of elements on a chain of insulators. The estimation of the flashover performance of polluted insulators is based on field experience and laboratory tests are invaluable as they significantly reduce the time and labour involved in insulator design and selection. The majority of the variables to be predicted are dependent upon several independent variables. The results from this work are useful to predict the contamination severity, critical flashover voltage as a function of contamination severity, arc length, and especially to predict the flashover voltage. The validity of the approach was examined by testing several insulators with different geometries. A comparison with the Grouping Multi-Duolateration Localization (GMDL) method proves the accuracy and goodness of LS-SVM. Moreover LS-SVMs give a good estimation of results which are validated by experimental tests.
EN
The flashover of pollution, observed on the insulators used in high voltage transmission, is one of the most important power transmission stakes. It is a very complex problem due to several factors including the modelling difficulties of complex shapes of insulators, different pollution densities at different regions, non-homogeneous pollution distribution on the insulator surface and unknown effect of humidity on the pollution. In the literature, some static and dynamic models have been developed by making some assumptions and omissions to predict the flashover voltages of polluted insulators. This paper aims to experimentally analyse the flashover process and simulation of the distributions of the potential and the electric field under 50 Hz applied voltage on a real model simulating the 175CTV outdoor insulators largely used by the Algerian Company of Electricity and Gas (SONELGAZ). This real model is studied under non-polluted (distilled water), and polluted (distilled water and sand) environments. The simulations were carried out by using the COMSOL multiphysics software. This program uses the finite element method to solve the partial differential equations that describe the field. Experimental results made in the laboratory and simulation results are original and found to be congruent.
EN
Flashover of polluted insulators has been the subject of many experimental and numerical research papers. Several mathematical models of flashover voltage have been proposed in terms of current, discharge length, electrolyte length and resistivity. However, there is no model as yet based on the geometric factors of the electrolyte channel-such as width and depth-and the interaction between them. Furthermore, as very few research papers have been published about discharge elongation in the presence of a metal object between the electrodes, the aim of the present work is to model flashover voltage in the presence of a metal plate, dipped in electrolyte or placed on its surface. Two mathematical models were obtained using response surface modeling and they were used in the analysis of the effect of geometric factors on the flashover discharge.
7
Content available remote Structural analysis of adaptive bistable composites
EN
Anisotropic composites are generally characterised by residual stresses, which primarily occur during the manufacturing at elevated temperature and a subsequent cooling. These residual stresses often lead to a warpage of the composite and in special cases of unsymmetrically built up composites even to large out-of-plane deformations with two stable deformation states. Those so-called bistable composites can beneficially be used for the development of novel adaptive structures if appropriate actuators are integrated, which permit to initiate a permanent change of the composite shape by a snap-through, generated only by a brief energy impulse. For the structural analysis of such adaptive bistable composites based on fibre and textile reinforced thermoplastic or thermosetting matrix systems respectively, a nonlinear semi-analytical simulation model has been elaborated, using a three-stage Ritz method according to the manufacture process of laminate consolidation, actuator bonding and actuator activation. The semi-analytical simulation model enables fast structural analysis of elementary bistable composites and efficient parameter studies. Additionally, numerical simulation models using the finite element analysis have been developed in order to perform a coupled electromechanical structural analysis of the actuator initiated snap-through behaviour of unsymmetric composites with a rather complex structural lay-up and geometry. The simulation models have been validated and were used to design first prototypes of adaptive bistable composites. Manufacture studies and experimental investigation on those prototypes illustrate the successful functional proof of novel intelligent structures and confirm the elaborated theoretical design process.
PL
Kompozyty anizotropowe są zazwyczaj charakteryzowane przez naprężenia szczątkowe, które występują głównie podczas produkcji w podwyższonej temperaturze oraz w czasie poźniejszego chłodzenia. Naprężenia te często prowadzą do wypaczenia kompozytu, a w przypadku niesymetrycznej budowy kompozytu nawet do dużych deformacji powierzchni, z dwoma stanami stabilnymi. Te tak zwane bistabilne materiały kompozytowe mogą z powodzeniem zostać zastosowane w wytwarzaniu nowoczesnych struktur adapcyjnych, jeśli odpowiednio zintegruje się elementy aktywujące, które dzięki wprowadzeniu energii w postaci impulsu inicjują przeskok (snap-through), a co się z tym wiąże - zmianę kształtu. Do analizy strukturalnej bistabilnych kompozytów na bazie tworzyw termoplastycznych lub termoutwardzalnych wzmocnionych włóknem lub tkaniną opracowano półanalityczny model obliczeniowy oraz model symulacyjny z wykorzystaniem trójpoziomowej metody Ritza, odpowiadającej procesowi wytwarzania, czyli kolejno: zagęszczanie laminatu, dołączenie czynnika aktywującego oraz jego aktywowanie. Ten półanalityczny model umożliwia szybką analizę strukturalną bistabilnych materiałów kompozytowych oraz również efektywną ocenę ich parametryzacji. Dodatkowo zostały opracowane modele numeryczne przy wykorzystaniu metody elementów skończonych w celu przeprowadzenia elektromechanicznej analizy strukturalnej elementów zjawiska przebicia inicjowanego czynnikiem aktywującym o złożonej strukturze warstwowej i złożonej geometrii. Modele te zostały zweryfikowane eksperymentalnie i z powodzeniem zastosowane do wykonania pierwszych prototypów kompozytów bistabilnych. Badania eksperymentalne oraz doświadczenia z procesu wytwarzania tych prototypów są dowodem praktycznego zastosowania nowych struktur inteligentnych i potwierdzeniem opracowanego teoretycznie procesu konstrukcyjnego.
8
Content available remote The analysis of backflashovers in high voltage overhead lines
EN
Reliability of the electrical power transmission and distribution system depends on the progress in insulation coordination, which is conditioned, among other factors, by increasing possibilities to identify surge hazards to insulating systems. Presently, theoretical methods of analysis are intensively developed, particularly in the domain of lightning surges. These methods utilize both the mathematical models of physical phenomena and the computer-aided calculating techniques. In this paper, a model power line impacted by lightning surges is described; when using this model, it is possible to analyze surge hazards generated by direct lightning discharges, with the impulse electric strength included. The model developed has been applied to analyze statistically a backflashover phenomenon produced by direct lightning strokes hitting power line towers.
PL
Niezawodność przesyłu i rozdziału energii elektrycznej zależna jest od postępu dokonującego się w koordynacji izolacji, który wynika między innymi z rozwoju możliwości identyfikacji narażeń przepięciowych oddziałujących na układ izolacyjny. Obecnie intensywnie rozwijane są metody teoretyczne analizy - szczególnie w zakresie przepięć atmosferycznych - wykorzystujące modele matematyczne zjawisk i komputerową technikę obliczeniową. W publikacji przedstawiono model linii elektroenergetycznych w warunkach oddziaływania przepięć atmosferycznych. Model umożliwia analizę narażeń przepięciowych powstających w wyniku bezpośrednich wyładowań piorunowych, z uwzględnieniem udarowej wytrzymałości elektrycznej. Opracowany model zastosowano do statystycznej analizy zjawiska przeskoku odwrotnego wywołanego , bezpośrednimi uderzeniami pioruna do konstrukcji wsporczych linii.
EN
The electrogeometric model is now widely used for the dimensioning of lightning protection systems of ground structures. This model has the advantage of taking into account the magnitude of the lightning current and its statistical distribution but has a weakness in that it does not include the shape of electrode of the ground structure. This paper describes a laboratory experiment to investigate the dependence of the striking distance of a descending negative discharge on the shape of the ground electrode/structure. A theoretical study, based on the Lemke streamer-leader model, is also described. In this study, the streamer discharge is assumed to grow into a stable leader in the space between two electrodes when the streamer reaches a critical length, associated with the shape and polarity of the energized electrode. The experimental model uses an air-water interface in which the water conductivity is varied. The experimental results agree with the theoretical predictions.
PL
W projektowaniu układów ochrony odgromowej budowli naziemnych wykorzystuje się szeroko modele elektryczno-geometryczne. Ich zaletą jest możliwość uwzględnienia wartości prądu wyładowania i jego rozkładu statystycznego, wadą - niemożliwość analizy wpływu kształtu elektrod uziemieniowych. Artykuł przedstawia badania laboratoryjne zależności długości drogi przeskoku udaru o biegunowości ujemnej od kształtu elektrody uziemieniowej. Przedstawiono również analizę teoretyczną problemu w oparciu o model strimerowo-liderowy Lemkego. W analizie tej założono, że wyładowanie strimerowe przechodzi w ustabilizowane wyładowanie liderowe w przestrzeni międzyelektrodowej gdy strimer osiąga długość krytyczną, zależną od kształtu i biegunowości elektrody uziemieniowej. W modelu laboratoryjnym wykorzystano układ woda-powietrze ze zmienną konduktywnością cieczy. Wyniki badań laboratoryjnych są zgodne z analizą teoretyczną.
10
Content available remote Thermo-electrodynamics of rigid superconductors
EN
This paper deals with a continuum model of rigid superconductors. It is assumed that their property of shifting to the superconductive state for suitable values of temperature and magnetic field is due to a vectorial internal variable, related to the superelectron current by a linear constitutive law. The compatibility of the model with the second law of thermodynamics is investigated. The propagation of thermo-electromagnetic waves through a one-dimensional conductor is analyzed as well. Comparison is made with different continuum approaches which may be found in the literature.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.