EN
The article presents the results of a comparative analysis of the basic indicators characterizing the interruptions in the supply of electricity. On the basis of generally available reports of selected DSOs, a list of selected indicators was prepared over the years. A comparison of these data was made, for the largest energy distribution companies in Poland. Conclusions from this analysis may be used to determine the level of power supply reliability and energy security of the country.
PL
W artykule przedstawiono wyniki analizy porównawczej podstawowych wskaźników charakteryzujących przerwy w dostawach energii elektrycznej. Na podstawie ogólnie dostępnych raportów wybranych OSD opracowano zestawienia wybranych wskaźników na przestrzeni lat. Dokonano porównania tych danych, dla największych spółek dystrybucyjnych w Polsce. Wnioski z tej analizy mogą być wykorzystane do określenia poziomu niezawodności dostaw energii elektrycznej i bezpieczeństwa energetycznego kraju.
PL
Finansowy ekwiwalent za złą jakość dostarczanej odbiorcom energii elektrycznej określony został w polskim prawie tylko dla dwu parametrów, charakteryzujących tę jakość: dla odchyleń napięcia poza ich zakres dopuszczalny oraz dla przerw w zasilaniu odbiorców. Na przestrzeni lat nie zmienił się sposób wyznaczania bonifikat, związanych z tymi parametrami, a zmieniały się jedynie ich wartości. Aktualnie wartości te oparte są na średniej cenie sprzedaży energii na rynku konkurencyjnym w poprzednim roku kalendarzowym. W referacie dokonano analizy wysokości obu bonifikat i wykazano brak korelacji między ich wartościami oraz brak związku tych bonifikat z powszechnie stosowaną miarą ekonomicznych strat z powodu braku zasilania odbiorców. Miarą tą jest średnia wartość niedostarczonej energii, wyznacza¬na jako iloraz PKB i ilości zużytej energii przez wszystkich krajowych odbiorców w ciągu roku. Przedstawiono propozycję zmian wysokości bonifikat za złą jakość dostarczanej odbiorcom energii elektrycznej w zakresie ww. parametrów.
EN
The financial equivalent of the poor quality of electricity supplied to consumers was defined in Polish law by almost only two parameters that characterize the quality: the voltage deviations beyond their acceptable range and for outages in energy supply. Over the years, the method of determining bonuses, associated with these parameters, has not changed, and only changed their values. Currently, these values are based on the average price of electricity sales in a competitive market in the preceding calendar year. In the paper an analysis of amount of both bonuses is presented and lack of correlation between their values as well as lack of association of these bonuses to the commonly used measure of economic loss because of outages is shown. This measure is the average energy not supplied, calculated as the ratio of GDP and the amount of energy used by all domestic customers throughout the year. Proposals alteration of bonuses for the poor quality of electricity supplied – in the frames of the above parameters – were presented.
PL
Omówiono potencjalne przyczyny przerw w zasilaniu chronionych odbiorników spowodowane zmianą stanu zasilacza UPS małej mocy. Zwrócono uwagę na zjawiska występujące podczas zmiany stanu zasilacza UPS z podstawowego w autonomiczny na skutek awarii sieci zasilającej. Przedyskutowano efekty prądu włączenia transformatora głównego oraz opóźnioną reakcję rozłącznika głównego w stanach przejściowych. Zaproponowano działania zmierzające do wyeliminowania potencjalnych przyczyn przerw w zasilaniu odbiorników.
EN
The paper provides an overview of the possible causes of interruptions in the power supply of equipment caused by change in operation modę of the UPS unit. Phenomena occurring while the UPS unit changes from basie to autonomous operation because of power failure are pointed out. In particular the effects of the magnetizing inrush current of the main transformer and delayed reaction of the main relay during transient states are discussed. Actions aimed to eliminate of the possible causes of interruptions in the power supply of equipment are proposed.