1
Content available remote Moving average signals for the static compensator control
EN
The shunt static compensator with the control based on the average signals is presented. Two control signals are considered - moving RMS value of grid voltage and moving average power of the energy source. The compensator generates reactive current computed in the real time with the use of the iterative method. The multiport representation of the grid is presented. Analytical and simulation results show how the iterative control of the compensator behaves for three kinds of control signals.
PL
Opisano sterowanie kompensatora statycznego z wykorzystaniem dwóch rodzajów sygnałów – przesuwnej wartości skutecznej napięcia sieci i przesuwnej mocy czynnej źródła energii. Kompensator generuje prąd bierny obliczany w czasie rzeczywistym z wykorzystaniem metody iteracyjnej. Pokazano wielowrotnikową reprezentację sieci elektrycznej. Analityczne i numeryczne wyniki pokazują jak przebiega sterowanie iteracyjne dla dwóch rodzajów sygnałów sterujących.
EN
The development and utilization of technology are always directly proportional to the need for electrical energy. Real-time power flow research is used to evaluate the effect of wind power generation fluctuations on existing conventional systems. This research was conducted on the South Sulawesi electricity network system using Modified Improved Particle Swarm Optimization (MIPSO). The real-time results show that the power loss in the conventional system that is interconnected with wind power plants is 63.9208 WM, less than the power loss in the conventional system, which is 85.9440 WM. Likewise, the cost of the generating system connected to a wind power plant is $23368.6622/hour, lower than the conventional system power of $23503.444/hour, reducing costs or efficiency by 0.5735%/hour. Real-time analysis of optimal power flow with MIPSO can be used to determine the effect of changes in power generated by wind power plants on the conventional power grid system of Southwest Sulawesi.
PL
Rozwój i wykorzystanie technologii są zawsze wprost proporcjonalne do zapotrzebowania na energię elektryczną. Badania przepływu mocy w czasie rzeczywistym służą do oceny wpływu wahań generacji wiatrowej na istniejące systemy konwencjonalne. Badania przeprowadzono na systemie sieci elektroenergetycznej Południowego Sulawesi przy użyciu metody Modified Improved Particle Swarm Optimization (MIPSO). Wyniki w czasie rzeczywistym pokazują, że strata mocy w systemie konwencjonalnym, który jest połączony z elektrowniami wiatrowymi, wynosi 63.9208 WM, czyli mniej niż strata mocy w systemie konwencjonalnym, która wynosi 85,9440 WM. Podobnie, koszt systemu wytwórczego podłączonego do elektrowni wiatrowej wynosi 233686622 USD/godz., czyli jest niższy niż konwencjonalna moc systemu wynosząca 23503,444 USD/godz., co zmniejsza koszty lub wydajność o 0,5735%/godz. Analiza w czasie rzeczywistym optymalnego przepływu mocy za pomocą MIPSO może być wykorzystana do określenia wpływu zmian mocy generowanej przez elektrownie wiatrowe na konwencjonalny system sieci energetycznej południowo-zachodniego Sulawes.
EN
During the operation of industrial supply power systems, sometimes it becomes desirable paralleling transformers, the characteristics of which do not quite correspond to such a procedure. When transformers are connected in parallel, any difference between their parameters causes the load to be redistributed between them compared to the previous operating mode they had been running separately. The paper deals with the problem of different capacity transformers paralleling within a mine power supply system.
PL
Podczas pracy przemysłowych systemów zasilania pożądana jest czasami równoległa praca transformatorów, których charakterystyki nie są w pełni przystosowane do takich warunków. Gdy transformatory są połączone równolegle, każda różnica pomiędzy ich parametrami powoduje zmianę ich obciążenia w porównaniu z indywidualną pracą każdego z nich. W artykule omówiono problematykę równoleglej pracy transformatorów różnej mocy w systemie zasilania kopalni.
EN
The work is intended to extend the application of a smart transformer on a radialdistribution system. In this paper, an updated algorithm on the backward/forward powerflow is introduced. The so-called direct approach of power flow is employed and analyzed.In addition, the paper focused on integrating a smart transformer to the network and solvingthe updating network also using the direct approach load flow. The solution of the smarttransformer using the direct approach power flow method is quite straightforward. Thismodel is applied to radial distribution systems which are the IEEE 33- and IEEE 69-bussystems as a case study. Also, the paper optimizes the best allocation of the smart transformerto reduce the power losses of the grid.
EN
The present article shows the results of an analysis of active power consumed by AC arc furnace at various stages of the melting process, taking harmonics into consideration. The analysis was based on measurement data in the form of computer recorded voltage and current waveforms in the power circuit of the arc furnace. Next the frequency analysis and the evaluation of the content harmonics of recorded waveforms were performed. Computation made using the fast Fourier transform FFT built-in in MATLAB. The active power of the arc furnace was determined on the basis of the classical theory of harmonic power distributions and instantaneous power after Clarke transformation to the orthogonal coordinate system α-β. Harmonic distribution phase currents and voltages were transformed using the FFT procedure, as well as distorted voltage/current waveforms registered as a sequence of samples. The obtained results demonstrate a high level of compatibility between the instantaneous power and active power for the methods under consideration.
PL
W artykule przedstawiono wyniki analizy mocy czynnej pobieranej przez piec łukowy AC w różnych etapach procesu wytopu z uwzględnieniem wyższych harmonicznych. Do analizy wykorzystano dane pomiarowe w postaci zarejestrowanych komputerowo przebiegów napięć i prądów w torze zasilania pieca łukowego. Następnie przeprowadzono analizę częstotliwościową i ocenę zawartości wyższych harmonicznych zarejestrowanych przebiegów. Obliczenia wykonano za pomocą szybkiej transformacji Fouriera FFT w programie MATLAB. Moc czynną pieca łukowego wyznaczono w oparciu o klasyczną teorię mocy dla rozkładów harmonicznych oraz na podstawie mocy chwilowej po transformacji Clarke’a do układu ortogonalnych współrzędnych α-β. Transformacji poddano uzyskane w procedurze FFT rozkłady harmoniczne prądów i napięć fazowych, a także zarejestrowane w postaci ciągu próbek odkształcone przebiegi napięciowo-prądowe. Uzyskane wyniki wykazują dużą zgodność mocy chwilowej i mocy czynnej dla rozpatrywanych metod.
EN
Unscheduled power flows are a serious problem for the Central and Eastern Europe (CEE) region. One method of reducing these undesirable flows relies on the use of phase shifting transformers (PSTs). This paper presents how the installation of PSTs on the Polish-German and Czech-German borders affects cross-border power flows in the CEE region, as well as interactions between these devices. The essential parameters proposed for PSTs are based on the effects arising from the application of PSTs on the border between Poland and Germany. The results demonstrate that the use of PSTs in the CEE region can provide effective control of active power flows in tie-lines and significantly reduce unscheduled flows. However, the operation of these devices must be coordinated in order to achieve maximum controllability and to guarantee the secure operation of the interconnected systems.
7
Content available Detection of Differently Loaded Power Network Areas
EN
A widely accepted method of simplifying power system problems, especially for large system, is solving them for areas into which a system is divided. The paper considers separation of the power system areas that contain branches with similar active or reactive power loads. For this purpose rates are proposed that show the dependence of the branch power flow (active and reactive power flow separately) on the loads at system nodes. On the basis of the considered rates, branches are partioned into groups. The rates for all branches in the same group are similar. They significantly differ between groups. For selected groups of branches, which are characterized by values of the aforementioned rate larger than a preset value, the consistent area of the power network is found. The paper shows utilization of the method for the IEEE 14-bus test system.
PL
Uznanym sposobem upraszczania problemów dotyczących systemu elektroenergetycznego, szczególnie o dużych rozmiarach, jest ich rozwiązywanie dla obszarów, na które system jest dzielony. W pracy rozważane jest wyodrębnianie obszarów systemu elektroenergetycznego, obejmujących gałęzie o podobnym obciążeniu przepływem mocy czynnej albo biernej. Na potrzeby przedstawianej metody zostały wprowadzone wskaźniki pokazujące zależność przepływu mocy (osobno mocy czynnej oraz mocy biernej) w gałęzi od obciążeń w węzłach systemu. Na podstawie branego pod uwagę wskaźnika dokonano podziału gałęzi na grupy. Dla gałęzi, należących do jednej grupy, wartości wskaźnika są do siebie zbliżone. Różnią się one istotnie od wartości rozpatrywanego wskaźnika dla innych grup. Dla wyróżnionych grup znajdowane są spójne obszary sieci elektroenergetycznej, które charakteryzują wartości wymienionego wcześniej wskaźnika większe od zadanej wartości. Wykorzystanie przedstawionej metody jest pokazane na przykładzie 14-węzłowego systemu testowego IEEE.
PL
Problem alokacji kosztów jest przykładem ogólnego problemu alokacji kosztów i korzyści wśród podmiotów, które współpracują przy budowie (wykorzystaniu) wspólnego zasobu, np. infrastruktury technicznej związanej z przesyłem czy dystrybucją energii (mocy), drogi czy np. obiektu użyteczności publicznej. W artykule – na podstawie przykładu – zostało zaprezentowane wykorzystanie metody śledzenia przepływów mocy do opisu przepływów finansowych za wykorzystanie elementów systemu – (w tym przypadku) gałęzi (linii, transformatorów).
EN
Cost allocation problem is an example of a general cost allocation and profits sharing among the companies (subjects) that cooperate in the construction of a common good e.g. technical infrastructure connected with transmission or distribution of power, a road or other community facilities. The paper presents an example of application of tracing power flow method to the description of financial flows for the use of elements of power system – girds (lines, transformers).
9
Content available remote Impact of Loads on Power Flow in Power Systems Using PowerApps and ETAP
EN
This paper presents a study of the impact of loads on power flow in power system. It deals with the impact of both the voltage nodes and the transmission of active and reactive power in lines, and therefore the loss of active and reactive power in the system. Flexible Alternating Current Transmission System (FACTS) devices are found to be encouraging in improving voltage stability limit in power systems. This paper investigates the application of FACTS devices (Static Var Compensator, SVC) on a 9-bus multimachine power system, it deal with the line losses and improving voltage stability limit. Amount of increased reactive power generation and line losses are taken as indicators of stressed conditions of a power system. The use of SVC is identified by PowerApps and ETAP software packages. Both software are used for IEEE 9 bus test system and the results obtained are presented and interpreted.
PL
Analizowano wpływ napięć w węzłach i przepływ mocy biernej i czynnej na pracę systemu energetycznego. Artykuł przedstawia badania zastosowania urządzeń FACTS w dziewi1)ęcioszynowym, wielomaszynowym systemie. Wykorzystano oprogramowanie ETAP.
10
Content available remote ANFIS UPFC Damping Controller for Multi machines Power Systems Oscillations
EN
The main purpose of this paper is to investigate an Adaptive Neuron- Fuzzy Inference System (ANFIS) based supplementary Unified Power Flow Controller (UPFC) in superimposing a damping function on the control signal of UPFC who’s incorporated in multi-machines power system. This control scheme designed to produce supplementary signal for damping oscillations in the interconnected power systems. The improved damping performance was studied and it is validated on a benchmark power system example taken from literature.The control actions are formulated as a set of local controllers, which are coordinated to maintain transient angle stability, transient voltage stability and damping of interarea and local oscillations following a disturbance.
PL
W artykule przedstawiono wyniki badania sterownika przepływu mocy UPFC wykorzystującego system ANFIS zastosowanego w systemie wielogeneratorowym. Celem było tłumienie oscylacji na połączeniach.
11
Content available remote Use of TCSC for Active Power Flow Control in the Electric Power System
EN
The article deals with possibilities of the thyristor controlled series capacitor (TCSC) to control power flows in interconnected electrical power systems. The main goal is to describe the working principle of TCSC and its possible use in the transmission system (TS) and advantages and disadvantages of using of such equipment in the electric power system.
PL
Artykuł dotyczy możliwości sterowanych tyrystorowo układów kompensacji szeregowej (TCSC) w kontrolowaniu przepływu mocy między połączonymi systemami elektroenergetycznymi. Głównym celem jest opis zasad działania układów TCSC, możliwości ich wykorzystania w systemie przesyłowym (TS), oraz wad i zalet użytkowania takiego sprzętu w systemie elektroenergetycznym.
PL
Opisano modele przepływu mocy stosowane przy wyznaczaniu sprawności silników indukcyjnych klatkowych. Modele te są stosowane w różnych normach. Autor przedstawia swój oryginalny model oraz związane z nim dwie nowe metody wyznaczania sprawności.
EN
Described are power flow models used for determination of induction squirrel-cage motors efficiency. These models are used according to different standards. Presented is the author's original model and the relevant two new efficiency determination methods.
PL
Referat dotyczy możliwości zastosowania przekształtników matrycowych w systemach elektroenergetycznych, ze szczególnym uwzględnieniem układów FACTS oraz układów generatorów wirujących. Przedstawiono zasadę działania, właściwości i wybrane topologie takich przekształtników, w tym również tzw. układów pośrednich i wielokomórkowych. Pokazano i przeprowadzono wstępną ocenę wybranych elektroenergetycznych aplikacji przekształtników matrycowych, odniesioną do innych stosowanych układów energoelektronicznych.
EN
Paper presents properties and possibilities of the matrix converters application in electric power systems. Advantage and limit possibilities for application this converters in transmission and distributed lines were considered. Some aspects concerning work were talked over and most important topologies of the converters, as well indirect and multi-cell matrix converters. Possibilities of usage matrix converters arrangements with traditional compensators in distributed networks were considered.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.