Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  przenoszenie ładunku
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The sample simulation researches of the laboratory truck crane have been carried out in the paper. Results, which are the system response to the taken kinematic forcings, have been obtained in the form of animation of motion of the whole system and in the form of the motion trajectories of the load lifted on the rigid and elastic rope.
PL
Badania symulacyjne umożliwiają dokładniejsze poznanie analizowanego obiektu, zwiększenie efektywności jego działania, a także pozwalają utworzyć wirtualne środowisko pracy i wypróbować wiele alternatyw sterowania i kontroli zachowania układu w czasie realizacji powierzonych mu zadań. Różnorodność oraz zakres budowanych modeli symulacyjnych jest coraz szerszy dzięki rozwojowi oprogramowania, co z kolei pozwala na uzyskanie bardziej wiarygodnych modeli.Wykorzystując wymienione powyżej aspekty, w niniejszej pracy wykonano badania symulacyjne pozwalające określić zachowanie układu laboratoryjny żuraw samochodowy [1] – przenoszony ładunek na zaproponowany cykl roboczy. Do przeprowadzenia badań symulacyjnych został wykorzystany model przyjęty w pracy [2], który rozbudowano o uwzględnienie zaburzeń wynikających z fizykalnych własności układu linowego [3].
EN
The paper presents results of computation of electrostatic field distribution on the surface of the metallic ball electrode for measurements of electric charge transferred during provoked electrostatic brush discharges between electrode and electrified dielectric. The electrode consisted from the shielding ball of 30 mm diameter and insulated thin central electrode for charge collecting. It was proved that in the case of distance between electrode and dielectric less than 50 mm, discharge current can obey the central electrode.
PL
W artykule przedstawiono wyniki obliczeń numerycznych rozkładu natężenia pola elektrycznego na kulistej powierzchni ekranowanej sondy do pomiaru ładunku przenoszonego w czasie prowokowanego wyładowania snopiastego między powierzchnią naelektryzowanego dielektryka i sondą. Wykazano, że w przypadku małych odległości (poniżej 50 mm) między typową sondą o średnicy 30 mm i powierzchnią dielektryka, prąd wyładowania może omijać centralnie umieszczoną w sondzie elektrodę pomiarową.
EN
In the paper there was presented the theoretical analysis of the accuracy of the measurement of the electric charge transferred through the plasma channel of electrostatic spark discharge by applying the discharge, metallic ball electrode loaded with the high quality capacitor. It was proved that applying the measurement capacitor of sufficiently high capacity, the error of the charge measurement could be freely decreased.
PL
W artykule przedstawiono teoretyczną analizę dokładności pomiaru ładunku elektrycznego przenoszonego przez kanał plazmowy w czasie iskrowego wyładowania elektrostatycznego, za pomocą metalowej, kulistej elektrody wyładowczej, obciążonej nisko-stratnym kondensatorem Wykazano, że zwiększając pojemność kondensatora, można dowolnie zmniejszać błąd pomiaru spowodowany indukowaniem ładunku w obwodzie pomiarowym w czasie zbliżania sondy do obiektu naelektryzowanego, przed wystąpieniem wyładowania. (Dokładność pomiaru ładunku elektrycznego przenoszonego podczas wyładowania elektrostatycznego, za pomocą elektrody wyładowczej obciążonej pojemnościowo).
PL
Przedmiotem artykułu jest zagadnienie modelowania i analizy zjawisk dynamicznych układu przenoszenia ładunku, w jaki wyposażony jest żuraw leśny. Sformułowano i rozwiązano zagadnienie początkowe ruchu ładunku przenoszonego za pomocą żurawia w określonym cyklu roboczym. Opracowano model obliczeniowy umożliwiający analizę ruchu układu zarówno pod wpływem wymuszenia, jak i drgania swobodne ładunku. W pracy zamieszczono przykładowe wyniki symulacji ruchu ładunku.
EN
In this work the problem of modelling and analyzing of the dynamic effects of the load carrying system of the forest crane is considered. The initial problem of the load motion carried by the forest crane during the working cycle has been formulated and solved. The workout calculation model enable one to analyse the motion of the load under influence of kinematic forcing and the free vibration of the load as the result of the previous forced motion. In the work the exemplary results of the numerical simulation are presented.
EN
Two simple, fast, sensitive, and economical spectrophotometric methods for quantification of lisinopril in drug formulations have been developed. Method A was based on the reaction between primary amino group of the drug with N-bromosuccinimide in acetone medium giving a yellow-colored product of maximum absorption at 353 nm. Method B was based on the formation of purple-colored charge transfer complex between the drug and chloranil in 1,4-dioxan-acetonitriIe medium. Beer's law was obeyed in the concentration ranges of 10-200 and 24-600 μg mLTwo simple, fast, sensitive, and economical spectrophotometric methods for quantification of lisinopril in drug formulations have been developed. Method A was based on the reaction between primary amino group of the drug with N-bromosuccinimide in acetone medium giving a yellow-colored product of maximum absorption at 353 nm. Method B was based on the formation of purple-colored charge transfer complex between the drug and chloranil in 1,4-dioxan-acetonitriIe medium. Beer's law was obeyed in the concentration ranges of 10-200 and 24-600 ug mL'1 with molar absorptivities of 1.40 x 103 and 7.28 x 102 L-1 mol cm'1 for methods A and B, respectively. Regression analysis yielded the following calibration equations: A = -2.44 x 10-1 + 3.16 x 10-1 C and A = 5.39 x 10-4+ 1.65 x 10-3C for methods A and B, respectively. For both calibration equations correlation coefficients were 0.9999. Intra- and inter-day precisions were lower than 1.60%. The optimum experimental conditions for the proposed methods have been investigated. Methods A and B have been successfully applied to the analysis of lisinopril in drug formulations. The results have been statistically compared to these obtained applying the British pharmacopoeia method with molar absorptivities of 1.40 x 103 and 7.28 x 102 L-1 mol cm-1 for methods A and B, respectively. Regression analysis yielded the following calibration equations: A = -2.44 x 10-1 + 3.16 x 10-1 C and A = 5.39 x 10-4+ 1.65 x 10-3C for methods A and B, respectively. For both calibration equations correlation coefficients were 0.9999. Intra- and inter-day precisions were lower than 1.60%. The optimum experimental conditions for the proposed methods have been investigated. Methods A and B have been successfully applied to the analysis of lisinopril in drug formulations. The results have been statistically compared to these obtained applying the British pharmacopoeia method
PL
Opracowano dwie proste, szybkie, czule i ekonomiczne spektrofotometryczne metody ilościowego oznaczania lizynoprilu w preparatach farmaceutycznych. Metoda A jest oparta na reakcji picrwszorzędowej grupy aminowej leku z N-bromosukcynimidem w acetonie, w wyniku której powstaje żółty produkt wykazujący maksimum absorpcji przy df. fali 353 nm. Metoda B polega na tworzeniu purpurowego kompleksu z przeniesieniem iadunku miedzy lekiem a chloranilem w mieszaninie 1,4-dioksanu i acetonu. Prawo Beer'a było . spełnione w zakresie stężeń 10-200 i 24-600 1.40 x 103; absorpcja molowa wynosiła 1.40 x 103 and 7.28 x 102 L-1 mol cm-1, odpowiednio w przypadku metody A i B, W wyniku analizy regresji otrzymano dwa równania kalibracyjne A =-2,44 x 10-4 + 3,16 x 10-3 C oraz A = 5,39 x10-4 + 1,65 x 10-3 C, odpowiednio dla metody A i B. Obie metody zoptymalizowano i zastosowano z powodzeniem do analizy lizynoprilu w preparatach farmaceutycznych. Otrzymane wyniki porównano z wynikami uzyskanymi według Farmakopei Brytyjskiej.
EN
Complexes of Cu(II) chemically bonded to silica surface via iminoketonate groups were studied towards their use in gas chromatography. The packing was investigated to evaluate its usefulness in the analysis of aliphatic and aromatic hydrocarbons. A number of retention parameters was determined (retention factor — k, retention index — I, specific retention volume - Vg molecular retention index — ^Me), which enabled to characterize specific interactions between bonded metal and adsorbate molecules. A packing containing no bonded metal was also investigated and treated as reference. The physical and chemical properties of the packings were determined as well as possibilities of analytic use of the packings under study were presented.
PL
Prezentowana praca dotyczy wykorzystania w chromatografii gazowej chemicznie związanych z powierzchnią krzemionki, przez grupę ketoiminową, kompleksów miedzi. Otrzymane wypełnienie poddano badaniom mającym na celu określenie jego przydatności w analizie alifatycznych i aromatycznych węglowodorów. Wyznaczono parametry retencyjne (współczynnik retencji k, indeks retencji I, właściwa objętość retencji Vf, molekularny indeks retencji AMC), pozwalające na charakterystykę oddziaływań specyficznych związanego metalu z cząsteczkami adsorbatów. Pomiary przeprowadzono także dla wypełnienia bez związanego metalu, traktujące je jako referencyjne. Wypełnienia poddano również badaniom określającym ich właściwości fizykochemiczne oraz zademonstrowano możliwości analitycznego wykorzystania badanych faz stacjonarnych.
7
Content available remote Design of selective layers for solid state electrochemical gas sensors
EN
Conducting polymers offer a possibility for developing material properties that are critical to the sensitivity, selectivity and fabrication of potentiometric solid state gas sensors. The formation of charge transfer complex between the gaseous species and the semiconducting material results in chemical modulation of the work function of the polymer. Methods of primary doping of the conducting polymers that lead to a stable and adjustable value of the work function will be discussed using polyaniline as an example.
PL
Polimery przewodzące dają możliwość poprawienia tych właściwości materiałów, które decydują o czułości, selektywności oraz mają istotne znaczenie przy preparowaniu potencjometrycznych stałych sensorów na gaz. Tworzenie kompleksów z przeniesieniem ładunku między cząsteczkami gazu i półprzewodzącym materiałem prowadzi do zmian w funkcji pracy polimeru. W pracy przedyskutowano, na przykładzie polianiliny, metody domieszkowania przewodzących polimerów, które umożliwiają regulowanie i stabilizowanie wartości funkcji pracy.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.