1
PL
Dokonano oceny zawartości PCDD/F w kompostach wytworzonych z komunalnych i przemysłowych osadów ściekowych z uwzględnieniem ich pochodzenia i technologii produkcji na tle danych literaturowych dotyczących występowania dioksyn w osadach ściekowych.
EN
Municipal and sewage sludges and 13 composts produced from their mixts. were analyzed for polychlorinated dibenzo-dioxins and - furanes by gas chromatog. coupled with tandem mass spectrometry. The detd. concns. of the pollutants did not exceed the allowable concns. and the composts can be used as fertilizers in agriculture.
PL
W artykule zaprezentowano możliwość zastosowania ekologicznej oceny cyklu życia (LCA) jako wiodącej metody do oceny wpływu na środowisko odpadów przemysłowych i energetycznych. Z tego względu przeprowadzono analizę dostępnych danych, związanych z powstawaniem odpadów przemysłowych na terenie Polski. Stwierdzono, iż stanowią one 91,1% ze 135,2 mln ton ogólnie wytworzonych odpadów w 2012 roku. Zwrócono również uwagę na problem zagospodarowania odpadów energetycznych i przemysłowych oraz na zagrożenia płynące z ich składowania jako dominującej metody unieszkodliwiania. Przedstawiono ekologiczną ocenę cyklu życia produktu jako narzędzie możliwe do zastosowania w celu oceny wpływu na środowisko ubocznych produktów spalania (UPS) oraz przemysłowych osadów ściekowych. Na podstawie analizy danych stwierdzono, że LCA stanowi adekwatne narzędzie do przedstawionej tematyki zarządzania odpadami przemysłowymi w Polsce.
EN
In the article there is presented possibility of Life Cycle Assessment (LCA) application, as currently the leading method to the environmental impact assessment of industrial and energy wastes. Therefore there are analysed the most recent data relating for the formation of industrial wastes on Polish territory. It is observed that they represent 91.1% of the 135.2 million tons of general wastes generated in 2012. It is also considered the problem of energy and industrial wastes management and the risks associated with their storage, as the principal treatment method. The Life Cycle Assessment is introduced as a tool to assess the environmental impact of combustion by-products and industrial sewage sludge. Based on the data analysis is concluded, that LCA is an appropriate tool to presented the subject of industrial waste management in Poland.
PL
Celem prezentowanej pracy jest analiza możliwości usuwania metali z osadów oraz określenie skuteczności roztworów EDTA (kwas etylenodiaminotetraoctowy) w procesie ekstrakcji wybranych metali (Zn, Cu, Cd, Ni i Pb). W badaniach wykorzystano osady z przemysłu metalurgicznego oraz komunalne osady ściekowe. W osadach oznaczono całkowitą zawartość metali ciężkich po mineralizacji mieszaniną stężonych kwasów mineralnych: HNO 3 i HCl (1+3 - woda królewska). Efektywność EDTA w usuwaniu metali badano, poddając próbki osadów ekstrakcji z zastosowaniem wody demineralizowanej oraz roztworów wodnych EDTA o stężeniach 0,01; 0,05; 0,10 mol/dm3 . Próbki osadów wytrząsano przez 6 godzin, następnie pozostawały one w kontakcie z roztworem do 24 godzin, po czym były sączone i uzyskane przesącze analizowano, oznaczając w nich zawartość wybranych metali ciężkich. Roztwory EDTA okazały się wydajnymi ekstrahentami do wyodrębniania metali zarówno z osadów przemysłowych, jak i komunalnych. Jednak obserwowano różnice dla poszczególnych metali w podatności na wymywanie. Uzyskane wyniki wskazują, iż efektywność usuwania metali zależy od rodzaju matrycy, w jakiej związany jest metal. Efektywność usuwania metali była również zależna od stężenia roztworu stosowanego jako ekstrahent, osiągając najwyższe wartości dla roztworów o stężeniu 0,100 mol/dm3.
EN
Sewage sludge formed in industrial wastewater treatment plants contains high amount of heavy metal ions. Especially electroplating, metallurgical, semiconductors production and printed circuit board industry generate wastewaters containing toxic metal ions. Significant concentration of heavy metals could be present in municipal sludge, especially one produced on treatment plants with high inflow of industrial wastewater. Classical treatment of that wastewater involving chemical precipitation under alkaline condition results in hazardous solid waste. High concentration of heavy metals in sludge is one of the most important environmental problems. The aim of this study was analysis of heavy metals removal from sewage sludge as well as determination of selected heavy metals (Zn, Cu, Ni, Cd and Pb) removal efficiency from industrial and municipal sludge using aqueous solutions of EDTA (ethylenediaminetetraacetic acid). Total content of analysed heavy metals (Zn, Cu, Ni, Pb) in sewage sludge was determined after digestion with mixture of concentrated mineral acids: HNO 3 and HCl (1+3 - aqua regia). Efficiency of EDTA solutions for selected heavy metals removal from industrial and municipal sludge was determined using the single step washing tests with deionized water and EDTA solution at concentration 0.010, 0.050, 0.075 and 0.100 mol/dm3 . Samples of dried and homogenized industrial as well as municipal sludge were shaken for 6 hours with EDTA solutions. The extracts were filtered and finally analyzed for heavy metals content by atomic absorption spectrophotometry. The removal of analyzed metals was dependent on concentration of extracting agent and raised with increasing concentration of EDTA. Optimal concentration of EDTA for analyzed heavy metals removal from industrial and municipal sludge was determined as 0.100 mol/dm3 . Calculated efficiencies for optimal concentration of EDTA solution used for industrial sludge extraction were 68, 67, 19, 60 and 41% and for municipal sludge: 26, 5, 35, 25 and 50% for Zn, Cu, Ni, Cd and Pb, respectively. Studied metals removal from the industrial wastewater sludge was in the order: Zn ≥ Cu>Cd>Pb>Ni and from the municipal: Pb>Ni>Zn ≥ Cd>Cu. The results indicated that heavy metals removal efficiency changed for different types of solid matrix. Zinc, copper and cadmium were strongly connected to municipal organic type sludge, while lead and nickel rather to mineral industrial sludge.
4
Content available remote Tiksotropia osadów powstających w galwanizerni
PL
Przeprowadzono ocenę właściwości tiksotropowych osadów na podstawie wyznaczonej doświadczalnie pętli histerezy. Do badań zastosowano przemysłowe osady ściekowe pochodzące z galwanizerni, zlokalizowanej na terenie zakładu zajmującego się nakładaniem powłok galwanicznych. Osady kondycjonowano wstępnie polem ultradźwiękowym przez 5 sekund, stosując amplitudy 8, 12, 16 μm, a następnie dodawano polielektrolitu Praestol 2515. Dawki polielektrolitu dobrano na podstawie testu CSK. Oceny badanych układów dokonano w przedziale zmian prędkości deformacji 0 ÷ 100 s-1 w czasie 228 s oraz w zakresie 100 ÷ 0 s-1 w czasie 114 s i temperaturach: 15, 20, 25°C. Na podstawie przeprowadzonych pomiarów otrzymano zbiory punktów wyznaczających krzywe płynięcia, które nie pokrywały się, dając pętle histerezy. Przeprowadzono również obliczenia powierzchni pętli histerezy oraz wskaźnika tiksotropii. Na podstawie uzyskanych wyników stwierdzono, że istnieje wpływ temperatury oraz amplitudy drgań na wartość wskaźnika tiksotropii. Przedstawione wyniki badań właściwości tiksotropowych przemysłowych osadów ściekowych są dowodem na niestabilność struktury badanych osadów.
EN
The paper presents the results of research concerning the impact of industrial sewage sludge conditioning on changes of rheological parameters. The sludge was choosen from a galvanizing plant. Preliminary, the samples were sonicated for 5 seconds using three different amplitudes 8, 12, 16 μm (the field of 22 kHz was used) and next, polyelectrolytes were used for sludge conditioning anionic polyelectrolyte Praestol 2515. Based on the CST test the optimum doses of polyelectrolyte were determined and added to sludge prior to rheological measurements. The experiment was performed at three temperatures 15, 20, 25°C. The rheological tests were carried out at the shear rate from 0 to 100 s-1 during 228 s and from 100 to 0 s-1 during 114 s. Basing on the histeresis loop the thixotropic coefficients were calculated, and the relationships between them and the temperature. The change of temperature influences on the thixotropic properties of the sludge structure. Thixotropic coefficients show that the structure of industrial sludge is not stabile. Therefore rheological properties are a useful tool in sludge characterization as it allows to determine the stability of structure and the resistance to shearing stresses during sludge conditioning.