The paper presents an example of the determination of moment resistance for a liner tray restrained by sheeting according to the rules given in standard PN-EN 1993-1-3 [12].
PL
W artykule przedstawiono przykład obliczeniowy wyznaczania nośności przy zginaniu kasety ściennej usztywnionej poszyciem wg wytycznych normy PN-EN 1993-1-3 [12].
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper presents select problems of resistance of cold-formed bending elements with C-cross-section according to PN-EN 1993-1-3 and PN-B-03207. The study is concentrated on the analysis of effective area of C-section with the single edge fold stiffener and the effects of local and distortional buckling. The difference of the calculation rules according to this normative documents are presented. It was proved that the procedure given in does not enough correlate with the results given by and Sharp and Hancock's modification metod. It is therefore possible that the buckling factor should be in given by the same formula as in.