The paper shows and discusses the problem of volume force densities in implant titanium and tantalum during magnetic tube assembling to a roller. Time and space distribution of radial volume force density in the tube as well as in the roller was determined. The significant differences between time and space distribution of volume radial forces in the tube and roller were found depending on the material of a roller.