Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  prompt gamma ray
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Radioisotope applications in industrial process inspection and evaluation using gamma-ray emitters provide otherwise unavailable information. Offering alternative gamma-ray sources can support the technology by complementing sources’ availability and radiation safety. This work proposes to replace gamma-ray from radioisotopes with prompt gamma-ray from the interaction of neutrons with stable isotopes injected into the industrial process or with the structural material of the industrial process equipment. Monte Carlo N-Particle Transport Code (MCNP5) was used to simulate the irradiation of two-phase fl ow pipes by 252Cf neutron source. Two simulations were run for each pipe, with and without mixing the liquid phase with the stable isotope 157Gd. The detected gamma-ray spectra were analysed, and images of the two phases inside the pipes were produced. The images were compared to images obtained from simulations of gamma transmission measurement using 60Co. Furthermore, results for prompt gamma computed tomography (CT) were presented and discussed. The studies’ outcomes indicate the potential of prompt gamma-ray to carry out the sealed sources applications of gamma transmission measurements and imaging.
EN
The aim of this study was to investigate the thermal neutron measurement capability of a CdZnTe detector irradiated in a mixed gamma-neutron radiation fi eld. A CdZnTe detector was irradiated in one of the irradiation tubes of a 241Am-Be source unit to determine the sensitivity factors of the detector in terms of peak count rate (counts per second [cps]) per neutron flux (in square centimeters per second) [cps/neutron•cm–2•s–1]. The CdZnTe detector was covered in a 1-mm-thick cadmium (Cd) cylindrical box to completely absorb incoming thermal neutrons via 113Cd(n,γ) capture reactions. To achieve, this Cd-covered CdZnTe detector was placed in a well-thermalized neutron fi eld (f-ratio = 50.9 ± 1.3) in the irradiation tube of the 241Am-Be neutron source. The gamma-ray spectra were acquired, and the most intense gamma-ray peak at 558 keV (0.74 γ/n) was evaluated to estimate the thermal neutron fl ux. The epithermal component was also estimated from the bare CdZnTe detector irradiation because the epithermal neutron cutoff energy is about 0.55 eV at the 1-mm-thick Cd filter. A high-density polyethylene moderating cylinder box can also be fi tted into the Cd fi lter box to enhance thermal sensitivity because of moderation of the epithermal neutron component. Neutron detection sensitivity was determined from the measured count rates from the 558 keV photopeak, using the measured neutron fluxes at different irradiation positions. The results indicate that the CdZnTe detector can serve as a neutron detector in mixed gamma-neutron radiation fields, such as reactors, neutron generators, linear accelerators, and isotopic neutron sources. New thermal neutron filters, such as Gd and Tb foils, can be tested instead of the Cd filter due to its serious gamma-shielding effect.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.