Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pressure drop method
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In order to explore the gas holdup distribution of the microbubble countercurrent contact flotation column in the hematite column cationic reverse flotation process, respectively using conductance method and pressure drop method for air and water as experimental medium characteristics research of flotation column, the research group carries on the gas holdup, examines the aeration quantity, the fill medium and cation collector alkyl polyamine ether (An amine collector―GE609 which consists of four elements: carbon, hydrogen, oxygen and nitrogen)within the column on the influence of the axial and radial gas holdup. The results show that the axial gas holdup from the bottom of the column to the top of the column increases with the increase of height in the range of 0.050.07dm3/s. The radial distribution of gas holdup generally shows the distribution law of “intermediate high, low on both sides”. After the filling medium is added into the column, the radial gas holdup is evenly distributed compared with the empty column, and the gas holdup is increased. Due to the high foaming performance of GE-609, the gas holdup in the column can be increased by changing the amount of aeration and the concentration of the reagent, which can exceed 60% at the maximum. Like other alcohol foaming agents, as time passes, the effect of GE-609 weakens and the gas holdup in the column gradually decreases. The addition of quantitative HCl can improve the foaming performance of GE-609, and the gas holdup in the column is significantly improved and the stability is enhanced.
EN
This study applied a modified OxiTop® system to determine the oxygen uptake rate during a 2-day respiration test of selected composting materials at different moisture contents, air-filled porosities and composition of composting mixtures. The modification of the OxiTop® respirometer included replacement and adjustment of a glass vessel (i.e. a 1.9-L glass vessel with wide mouth was used instead of a standard 1-L glass bottle, additionally the twist-off vessel lid was adjusted to attach the measuring head) and application of a closed steel mesh cylinder of 5 cm in diameter and 10 cm in height with the open surface area of the mesh of approximately 56.2%. This modification allowed obtaining different bulk densities (and thus air-porosities) of the investigated composting materials in laboratory composting studies. The test was performed for apple pomace and composting mixtures of apple pomace with wood chips at ratios of 1:0.5, 1:1, 1:1.5 (d.w), moisture contents of 60%, 65% and 75% and air-filled porosities ranging from 46% to 1%. Due to diverse biodegradability of the investigated apple pomace and composting mixtures this test allows for the determination of the effects of different air-porosities (due to compaction in a pile) on the oxygen uptake rate for mixtures with a fixed ratio of a bulking agent. The described method allows for laboratory determination of the effects of moisture content and compaction on biodegradation dynamics during composting.
PL
W przedstawionych badaniach wykorzystano zmodyfikowany system OxiTop® do wyznaczenia szybkości oddychania w oparciu o zużycie tlenu podczas 2-dniowego testu respirometrycznego dla wybranych materiałów przeznaczonych do kompostowania o różnym składzie mieszanek, zawartości wody i porowatości. Modyfikacja systemu OxiTop® dotyczyła dostosowania szklanego naczynia oraz jego wyposażenie w cylinder w kształcie walca o średnicy 5 cm i wysokości 10 cm, wykonanego z siatki stalowej (oczka siatki stanowiły ok. 56,2% całkowitej powierzchni). Ta modyfikacja pozwoliła na uzyskiwanie różnych gęstości nasypowych (a tym samym porowatości) badanych materiałów w skali laboratoryjnej. Test respirometryczny został przeprowadzony dla wytłoków jabłkowych i mieszanek wytłoków jabłkowych i ścinek drzewnych w stosunku 1:0,5, 1:1, 1:1,5 (s.m) i zawartości wody 60%, 65% i 75% oraz porowatości w zakresie od ok. 46% do ok. 1%. Z uwagi na różną podatność badanych mieszanek na biodegradację, możliwe było określenie wpływu zmian porowatości powietrznej (spowodowanych kompakcją) na szybkość zużycia tlenu dla mieszanki o stałym udziale czynnika strukturotwórczego. Przedstawiona metoda pozwala na laboratoryjne badanie wypływu zawartości wody i kompakcji na biodegradację podczas kompostowania.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.