Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  precast lintel
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents the test results of reinforced precast lintels made of autoclaved aerated concrete (AAC) used to cover window openings in walls made of AAC masonry units. Walls were confined with reinforced lightweight concrete. The two variants of wall confinement with different way of lintel support and the static diagram of a simply supported beam and a constrained beam were tested. Cracks and deformations of test models around window openings were recorded with the Aramis software for non-contact measurements of displacements. Failure of lintels caused the loss of load capacity of test models. Lintels were cracked in the same way, but the sequence of crack formation and their location were different. The test results were compared with the test made for similar walls confined with ordinary concrete. Additional tie-columns did not significantly affected the load capacity of the test models contrary to the walls confined with ordinary concrete.
PL
W artykule przedstawiono wyniki badań ścian skrępowanych zbrojonym betonem lekkim wykonanych z elementów murowych z autoklawizowanego betonu komórkowego (ABK). Do przykrycia otworów okiennych zastosowano prefabrykowane zbrojone nadproża z ABK. Ściany skrępowano w dwóch wariantach zmieniając także sposób oparcia nadproży i schemat statyczny, belki swobodnie podpartej oraz belki utwierdzonej. Za pomocą systemu Aramis do bezdotykowego pomiaru przemieszczeń rejestrowano zarysowania oraz odkształcenia obszarów modeli badawczych wokół otworu okiennego. Zniszczenie nadproży spowodowało utratę nośności modeli badawczych Nadproża uległy zarysowaniu w analogiczny sposób, jednakże zmieniała się kolejność i lokalizacja poszczególnych rys. Wyniki badań porównano z wynikami uzyskanymi dla analogicznych ścian skrępowanych betonem zwykłym. Dodatkowe rdzenie żelbetowe nie wpłynęły w tak istotny sposób na nośność modeli badawczych jak to miało miejsce w przypadku ścina skrępowanych betonem zwykłym.
2
PL
Celem artykułu jest weryfikacja i określenie oporności na ścinanie prefabrykowanych nadproży o niskiej wysokości. We wstępie dokonano przeglądu literatury z zakresu badań elementów stosowanych do przykrycia otworów drzwiowych i okiennych w budownictwie. Zwrócono uwagę, iż tematyka badawcza związana z nadprożami jest ciągle aktualna i podejmowana przez środowisko naukowe i inżynierskie. W kolejnym rozdziale zebrano i opisano wybrane normowe procedury określania odporności na ścinanie elementów żelbetowych. Opis normowych procedur poprzedzono przeglądem literatury z zakresu ścinania w elementach żelbetowych. Określono charakterystyczne i obliczeniowe nośności na ścinanie prefabrykowanych nadproży betonowych według opisywanych procedur normowych i porównano je z wynikami uzyskanymi eksperymentalnie. Wskazano, iż możliwe jest oszacowanie odporności na ścinanie niskich belek nadprożowych na podstawie wybranych procedur normowych. Badania eksperymentalne belek nadprożowych prowadzone były na podstawie europejskiej normy opisującej metody określania odporności na ścinanie nadproży. Wyznaczono eksperymentalnie średnią siłę niszczącą badanych belek nadprożowych. Wykonano odwierty rdzeniowe, na podstawie których określono rzeczywistą wytrzymałość betonu na ściskanie. Na tej podstawie potwierdzono klasę wytrzymałości betonu na ściskanie. Przeprowadzono weryfikację rzeczywistego rozkładu zbrojenia w belkach nadprożowych dokonując odkrywek zbrojenia w badanych elementach.
EN
The scope of the paper is to investigate analytically and determine experimentally the shear resistance of low height reinforced precast concrete lintels. The chosen procedures included in national and international standards applied for the design of structural concrete elements to an estimation of shear behaviour of reinforced concrete elements are described. The characteristic and designed shear strength of precast concrete lintels are determined and compared with experimentally obtained results. The shear resistance for precast concrete lintels was determined by laboratory tests according to a European standard. The assessment of the in-situ compressive strength of concrete in precast concrete lintel is specified. The designed compressive strength class is confirmed. The real reinforcement distribution is verified to assess the wide scatter of experimentally obtained failure forces. A short literature outlook of the papers concerning investigations on lintels and shear resistance of concrete is given also. The paper can provide scientists, engineers, and designers a theoretical and experimental basis in the field of precast concrete lintels shear resistance.
3
Content available remote Analiza zachowania prefabrykowanych nadproży z ABK w ścianach skrępowanych
PL
W artykule przedstawiono wyniki badań zbrojonych prefabrykowanych nadproży z autoklawizowanego betonu komórkowego (ABK), obciążonych wraz z murem. Modele ścian wykonano w skali naturalnej w trzech wariantach: ściany nieskrępowanej; skrępowanej po obwodzie oraz skrępowanej obwodowo z dodatkowymi rdzeniami wzdłuż pionowych krawędzi otworu okiennego. Analizowano wpływ skrępowania na przebieg zarysowania i zniszczenia nadproży. Badania monitorowano za pomocą systemu Aramis do bezdotykowego pomiaru przemieszczeń (Cyfrowej Korelacji Obrazu - CKO), a wyniki analizowano za pomocą oprogramowania GOM Correlate.
EN
The paper presents results of experimental tests of reinforced precast lintels made of autoclaved aerated concrete (AAC) loaded with masonry wall. Three types of wall made in natural scale erected as: no confined wall, confined wall and confined wall with additional vertical reinforced concrete confining cores along vertical edges of window opening. Cracks’ propagation and destruction of lintels was analyzed. The tests were monitored by Aramis system for non-contact displacement measurement (Digital Image Correlation) and results were analyzed by GOM Correlate software.
4
Content available remote Nośność prefabrykowanych nadproży z ABK
PL
W artykule przedstawiono wyniki doświadczalnych badań kilku typów prefabrykowanych nadproży wykonanych z autoklawizowanego betonu komórkowego (ABK). Elementy miały identyczne gabaryty, a różniły się geometrią zbrojenia podłużnego i poprzecznego. Modele badano zgodnie z normowymi procedurami, każdorazowo analizując morfologię zarysowań, wartość sił niszczących oraz zależność obciążenie -przemieszczenie. Wyniki badań porównano z wynikami obliczeń przeprowadzonych zgodnie z normowymi procedurami.
EN
The article presents experimental results of several types of precast lintels made of autoclaved aerated concrete (AAC). The test specimens of identical dimensions, differed in geometry of longitudinal and transverse reinforcement. Models were tested according to standard procedures, each time analyzing the morphology of the cracking, the values of the destructive forces and the relationships of load -displacement. The results were compared with the results of the standard procedures calculations.
PL
W artykule przedstawiono wyniki badań doświadczalnych oraz obliczenia weryfikujące nośność stref przypodporowych prefabrykowanych nadproży z autoklawizowanego betonu komórkowego. Zbadano trzy serie elementów zróżnicowanych pod względem wymiarów poprzecznych oraz typu zbrojenia. Wykazano istotny wpływ sposobu zakotwienia podłużnych prętów na sposób zarysowania i zniszczenia oraz nośność belek.
EN
The paper presents the experimental results and analytical calculations of capacity of the ends of lintels made of Autoclaved Aerated Concrete. Three series of elements with different dimensions of specimens cross-section and types of reinforcement were taken into consideration. Significant influence of the method of anchoring of the longitudinal bars on the bearing capacity of the beams has been shown.
first rewind previous Strona / 1 next fast forward last