Experimental data collected from different plate-type electrostatic precipitators used in a thermoelectric power plant has been analyzed. The following parameters were considered: the collection efficiency, average migration velocity of dust particles, velocity distribution of the gas in the input and output channels of precipitators. The average migration velocity of dust particles can be estimated using various mathematical models, and the gas velocity can be computed using the velocity distributions from the input channels of the precipitators. The traveling time of dust particles between the electrodes is smaller than the traveling time along the precipitator sections.
PL
Usuwano jony miedzi z rozcieńczonych roztworów wodnych o pH = 4,5 w obecności kolektora anionowego SDS w procesie flotacji jonowej. Zbadano wpływ stężenia kolektora i prędkości przepływu powietrza na skuteczność usuwania jonów miedzi. Stwierdzono, że wzrost stężenia kolektora powoduje wzrost stopienia wyflotowania i spadek wartości współczynnika wzbogacenia. Wzrost prędkości przepływu powietrza wpływa na zmniejszenie współczynnika wzbogacenia i nie zmienia znacząco stopnia wyflotowania.
EN
Removal of Cu2+ ions from diluted aqueous solutions at pH = 4.5 using anionie collector (SDS) was investigated. An influence of collector concentration and linear gas velocity on the efficiency of copper ions removal was tested. It was found that an increase of collector concentration caused an increase of removal ratio and a decrease of enrichment coefficient. The increase of air velocity diminished the enrichment coefficient and did not affect considerably the removal ratio.
PL
W niektórych pyłomierzach grawimetrycznych stosowane są sondy aspiracyjne, których konstrukcja umożliwia (niezbędny dla utrzymywania izokinetyczności poboru i oznaczenia strumienia masy pyłu w kanale) pomiar prędkości gazu w miejscu ich ulokowania w przewodzie. Prędkość skorelowana jest z mierniczą różnicą ciśnień sondy, wielkością bezpośrednio mierzoną w czasie pracy pyłomierza. Związek ten jest charakterystyką metrologiczną danej sondy, wyznaczaną w procedurze wzorcowania. Dwa typy sond, a mianowicie sonda zerowa oraz sonda zwykła z filtracją wewnętrzną wyposażona w anemometryczny czujnik typu S, były przedmiotem badań. Na stanowisku laboratoryjnym sprawdzono zachowanie się charakterystyk sond w przepływach o różnej turbulencji. Otrzymane, przytoczone tu wyniki, wykazują, iż turbulentny stan przepływu gazu jest czynnikiem kształtującym ich charakterystykę metrologiczną. Wobec faktu, że turbulencja przepływu gazu nie jest identyfikowana w czasie pomiarów grawimetrycznych w instalacjach przemysłowych, stanowi ona przyczynę niepewności pomiaru prędkości gazu w przewodzie. Dla badanych sond podano wartości tej niepewności, zmienne z poziomem prędkości gazu. Opisano pomiarowy i obliczeniowy warsztat badawczy.
EN
Aspiration dust probes of some isokinetic samplers have such a construction that enables them to measure the gas velocity at the point they are placed in a duet, the measurement being required for maintaining isokinetic conditions and in determining the dust mass flow rate in the duet. The gas velocity is correlated with a probe specific pressure difference, a quantity measured directly when the train is in operation. This relationship is a metrological characteristic of a given probe, being established in a calibration procedure. Two types of the above-mentioned probes, namely a pressure balance-type and an in-stack filtration probes (in two versions) combined with a type S velocity sensor, have been tested. The behaviour of the characteristics of the probes was studied in the flows of different turbulence at a laboratory stand. The achieved results, presented in the paper, show that the turbulence state of gas flow is the factor that shapes the metrological characteristics. Facing the fact that the turbulence of gas flow in industrial installations is not identified during the dust concentration gravimetric measurements, this parameter constitutes a source of uncertainty of the gas velocity measurement. For the probes under test, the values of this uncertainty, varying with the gas velocity, were determined. The test and calculation procedures were described.
PL
Przy pomiarach prędkości gazu w przemysłowych kanałach przepływowych coraz częściej stosuje się różnego typu specjalne różnicowe sondy ciśnieniowe. W atrykule przedstawiono metodykę oraz wyniki badań porównawczych sondy walcowej względem znormalizowanej sondy typu L. Badania wykonano w obiektach energetyki zawodowej i cieplnej w szerokim zakresie prędkości gazu i zróżnicowaniej gazometrii przewodów.
EN
Practical studies of the cylindrical differential pressure sensor. In the measurement of gas flow velocity in industrial ducts various types of special differential pressure sensors are becoming more common. In the article the methodology and results of comparison between a cylindrical and a standardised L-type sensor have been presented. The studies have been carried out on heat and electric power engineering objects in wide range of gas speed and diversified ducts geometry.
PL
Poprawny przebieg niektórych procesów technologicznych (wentylacja, usuwanie zanieczyszczeń, oczyszczanie powierzchni, transport pneumatyczny itp.) wymaga zazwyczaj odpowiedniego przygotowania strumienia gazu. W pracy przedstawiono wyniki badań nad możliwością oddziaływania na kształt pola prądu strumienia powietrza generowanego przez wentylator osiowy do zamkniętego kanału o prostokątnym przekroju.
EN
Some technological processes (ventilation, pollutions removal, sufrace cleaning, pneumatic transportation etc.) demand for adequate flux of gas. In the work arę presented results of tests made on the possibility of affecting the form of air flux field generated by the axial fan into the closed channel of rectangular section.