Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  prąd niesinusoidalny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Effects of current on people are mainly considered for 50/60 Hz sinusoidal current and smooth direct current. However, modern low voltage circuits are very often equipped with power electronics converters – rectifiers, frequency converters, therefore non-sinusoidal earth currents (touch currents) occur. For non-sinusoidal currents safety criteria should be modified. This paper presents these modified criteria and a computer system of protection against electric shock which can be implemented in circuits with power electronics converters. The system is based on LabVIEW environment. Implementation of the safety system enables the disconnection of supply exclusively when real hazard of the ventricular fibrillation occurs.
PL
Skutki rażenia człowieka są najczęściej analizowane dla prądu sinusoidalnego o częstotliwości 50/60 Hz lub nietętniącego prądu stałego. Jednakże w nowoczesnych instalacjach niskiego napięcia pojawia się coraz więcej przekształtników energoelektronicznych – prostowników, przekształtników częstotliwości, a w takich obwodach mogą płynąć odkształcone prądy ziemnozwarciowe (prądy rażeniowe). Przy prądach odkształconych kryteria bezpieczeństwa powinny być zmodyfikowane. W artykule przedstawiono zmodyfikowane kryteria bezpieczeństwa oraz komputerowy system ochrony przeciwporażeniowej, wykorzystujący środowisko LabVIEW, przeznaczony do obwodów z przekształtnikami. Zastosowanie tego systemu pozwala na wyłączenie zasilania, kiedy pojawia się zagrożenie migotaniem komór serca.
PL
W opracowaniu przedstawiono koncepcję metody obliczeń kompensacji optymalnej i pełnej (w sensie Fryzego) odbiornika nieliniowego. Przyjęto założenie, że jedyną przyczyną odkształcenia jest odbiornik nieliniowy Sformułowano warunki redukcji odbiornika nieliniowego po kompensacji pełnej do quasi-liniowego rezystora o znanej charakterystyce P= f(U). Pokazano, że kompensacja pełna nie zawsze gwarantuje minimum wartości skutecznej prądu w linii zasilającej a nawet może w przypadku odbiornika nieliniowego spowodować jej wzrost. W tym celu dla uzyskania efektywnego zmniejszenia prądu sformułowano algorytm kompensacji optymalnej. Na wybranych przykładach zilustrowano i potwierdzono różne możliwe sytuacje kompensacji optymalnej w obwodach liniowych i nieliniowych.
XX
The paper presents the concept of the method and algorithm for optimal compensation of reactive power and full (in the Fryze sense) on the set of non-linear. It was assumed that the only source of strain is non-linear receiver. Formulated conditions for the reduction of non-linear receiver compensated fully for quasi-linear resistor of known characteristics P = f(U). It was shown that full compensation does not always guarantee a minimum RMS current in the power supply line even if the receiver can result in a non-linear increase. For this purpose, in order to obtain an effective reduction of the current optimal compensation algorithm formulated. Using examples, illustrated and confirmed various possible situations the optimum compensation of linear and nonlinear circuits.
3
Content available Kompensacja uogólnionej mocy biernej
PL
Uogólniona moc bierna jest określona przez powierzchnie pętli utworzonych przez charakterystyki prądowo napięciowe obiektów. Jest wielkością addytywną, zależy tylko od parametrów reaktancyjnych i jest zawsze równa zeru, jeśli energia elektryczna jest całkowicie rozpraszana w obiekcie. Uogólniona moc bierna jest także przydatna do poprawy współczynnika mocy. W artykule przedstawiono dowody, że jeśli uogólniona moc bierna zostanie skompensowana do zera, to przy niezmienionym napięciu, wartość skuteczna pobieranego przez obiekt prądu osiąga minimum, a współczynnik mocy wartość największą w danych warunkach pracy obiektu.
EN
Generalized reactive power is determined by the surface of the loop formed by the current-voltage characteristics of object. It is an additive quantity and depends only on the reactance parameters and is always equal to zero if the electricity is completely dissipated in the object. Its value is the basis for determining the parameters of the system to allow the desired improvement in power coefficient. The paper presents evidence that, if generalized reactive power is compensated to zero, then at a constant voltage, rms current drawn by the object reaches minimum, and power factor - the greatest value in working conditions of the object.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.