Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 15

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  power transmission lines
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Civil engineering projects deal with different risks over their life-cycle. Generally, risk sources are categorized into three types of cost, time, and project quality. The Modified Advanced Programmatic Risk Analysis Model (MAPRAM) is one of the leading approaches in this field that can assess the risks of the project on its whole life cycle. Electricity transmission lines have always been one of the most costly and time-consuming infrastructure projects. The costs of these projects play a significant role in a country's development budget. Given the considerable time and cost of constructing the foundations for power transmission towers, providing an economical design will significantly help in reducing duration and budget of these projects. In this study, using MAPRAM, first, different types of foundations of power transmission lines were studied; then the optimal foundations were introduced for a specific place as a case study, shaping a general framework to appoint the optimal foundation for power transmission lines in different areas. The foundations studied in this study included: pad & chimney foundation, auger foundation, steel grillage foundation, concrete piles, and helical piles. Initially, different types of foundations were designed, and then, the costs of each foundation in a whole life-cycle were estimated. Next, the risks and probability of their occurrence were identified for each type of foundation. Finally, the appropriate foundation was determined for the studied soil samples by performing an optimization process.
EN
The paper presents a method for investigating the electromagnetic transients of partially under-grounded high voltage overhead transmission lines in the presence of corona. It is based on a time domain model in which the corona is simulated by distributed voltage-dependent shunt current sources. The line segments and the inserted cable section are represented by a single equivalent transmission element having location-dependent circuit parameters per unit length. The numerical solution of the resulting set of differential equations yields the distributions of the voltage, the longitudinal current and the shunt corona current (per unit length) as functions of location and time. The presented two-, three-dimensional and contour plots proved to be helpful in discussing these distributions and in identifying any eventual current and/or voltage concentrations. The developed computer code in Mathematica can handle any time waveform of the source initiating the transients, any line termination as well as any lengths of the overhead line and cable section.
PL
W artykule omówiono wybrane wyniki badań wykonanych dla operatora sieci przesyłowej nad konstrukcją nowych, niskostratnych przewodów przewidzianych do stosowania w napowietrznych liniach elektroenergetycznych 400 kV. W szczególności omówiono wyniki porównania parametrów elektrycznych wybranych konstrukcji pojedynczych przewodów z przewodami referencyjnymi. Porównano również straty mocy i energii w liniach elektroenergetycznych z wiązkami wykonanymi z przewodów niskostratnych i obecnie stosowanych. Zastosowanie w liniach przesyłowych nowych, niskostratnych przewodów pozwoli na redukcję strat, w porównaniu ze stratami w liniach z przewodami referencyjnymi nawet o 30%.
EN
The article presents selected results of studies carried out for the transmission network operator on the construction of new, low-loss conductors intended for use in overhead power lines. Developed and treated multi-criteria analysis of new types of conductors steel-aluminium (ACSR), homogeneous alloy matrix aluminium (AAAC) Alloy-aluminium (ACAR) and using conductive cores made of copper based alloys, intended for use in bundles of 3-wire on existing towers and bundles of 3- and 4-wire on the new towers. We examined 80 projects of wires. The article discusses the impact of construction on the conductor resistance for alternating current and energy loss. We also compared the energy losses in power transmission lines equipped with bundles made of low-loss conductors with losses in the lines equipped with the currently applied wires. The use of the transmission lines with new low-loss conductors allows the reduction of energy losses in transmission lines by up to 30%, compared to the reference conductors (currently used).
PL
W artykule przedstawiono wyniki badań dotyczących nowych rozwiązań niskostratnych przewodów przewidzianych do stosowania w napowietrznych liniach przesyłowych 400 kV. Omówiono materiałowe i technologiczne aspekty projektowania przewodów oraz zagadnienia mechaniczne i elektryczne dotyczące zarówno przewodów jak i linii. Dokonano wielokryterialnej analizy 80 projektów nowych typów przewodów. Zastosowanie w liniach przesyłowych nowych przewodów pozwoli na redukcję strat nawet o ponad 25%, w porównaniu z obecnie stosowanymi przewodami.
EN
The article presents results of studies carried out on the construction of new, low-loss conductors intended for use in overhead 400 kV transmission lines. We discuss the material and technological aspects of designing conductors and issues relating to mechanical and electrical conductors on the line. Developed and treated multi-criteria analysis of new types of conductors. We examined 80 projects of conductors. The use of the transmission lines with new low-loss conductors allows the reduction of energy losses in transmission lines by up to 25%, compared to the actually used conductors.
EN
The paper deals with detection of hot spots in thermograms acquired during infrared inspections of power transmission lines. The author proposes an approach to automated selection of a threshold value for image segmentation using several methods of image processing and analysis. The algorithm is based on finding the steepest growth of successive gradients of sorted values of input image after certain image pre-processing steps. Several post-processing procedures were applied for proper visualization of detected regions in the resulting images. The results have brought satisfying effects and the algorithm, owing to its fast performance, could be also used on-line, during vision inspections.
PL
Artykuł dotyczy wykrywania gorących obszarów w termogramach uzyskanych podczas inspekcji termograficznych przesyłowych sieci elektroenergetycznych. Autor proponuje podejście do automatycznego doboru wartości progowej dla segmentacji obrazu przy użyciu kilku metod przetwarzania i analizy obrazu. Algorytm opiera się na znalezieniu najbardziej stromego wzrostu wśród wartości kolejnych przyrostów posortowanych wartości obrazu wejściowego po pewnych krokach wstępnego przetwarzania. Pewne procedury przetwarzania końcowego zostały zastosowane dla prawidłowej wizualizacji wykrytych regionów w wynikowych obrazach. Wyniki przyniosły zadowalające efekty i algorytm, dzięki swojemu szybkiemu działaniu, może być zastosowany również on-line, w trakcie inspekcji wizyjnych.
PL
W artykule zamieszczono wyniki badań mających na celu opracowanie technologii wytwarzania zaprasowywanego osprzętu elektroenergetycznego przeznaczonego dla linii wysokich i średnich napięć. Główny nacisk położono na dobór parametrów wyciskania i obróbki cieplnej, gwarantujących dobrą przewodność elektryczną oraz wymagane własności mechaniczne. Dzięki zastosowaniu stopu o składzie zbliżonym do przewodów, z którymi współpracuje, poprawiono odporność korozyjną całego złącza. Finalne badania zweryfikować miały możliwość zastosowania opracowanej technologii w produkcji przemysłowej, a prowadzone były w firmie Belos-PLP na wytworzonej przez nią partii próbnej [1].
EN
The paper presents the results of research aiming at developing technology of compression hardware for overhead power transmission lines. The main emphasis is put on parameters of extrusion and heat treatment to guarantee good electrical conductivity and mechanical properties. By using an alloy with a similar composition to the wires corrosion resistance of the entire joint have been improved. The final test was to verify the applicability of this technology in industrial production and were conducted at Belos-PLP on manufactured test run elements.
7
Content available remote Detection of Truss Structures in Computer Vision Using Image Processing
EN
Nowadays, truss structures are a commonly used solution among various kinds of buildings, mainly because of their advantageous structural characteristics and relatively low cost. Such objects are usually exposed tofatigue, mechanical and corrosion damage. Because they play important functions and their high reliability is required, their systematic diagnostics is very important. The paper presents a proposition of a method of automatic computer recognition of such structures in pictures (using image processing methods) during visual diagnostics, giving the example of a truss pylon.
EN
The article presents results of transitional processes computer simulation at switching-off unloaded power transmission line of rated voltage 220 kV by auto-compression (SF6) circuit-breakers. Transitional voltages (voltage across the line terminals and recovery voltage) at switching-off were calculated and studied in the research carried out. There was also considered dependence between transitional voltages magnitudes and power transmission lines lengths. There were studied some computational peculiarities of the problem under consideration. In particular, the numbers of pi-sections provided satisfactory adequacy of lines equivalency at computer simulation for their typical lengths were determined. There were also estimated optimum simulation parameters provided stability of transitional regime parameters.
PL
W artykule zamieszczono wyniki badań nad opracowaniem parametrów wytwarzania osprzętu linii energetycznych z zastosowaniem zmodyfikowanego stopu EN AW-6101 z dodatkiem Zr, mającego zastąpić szeroko używane do tych celów stopy EN AW- 6060, 2017, 6082. Badania prowadzone były w skali półtechnicznej, a następnie zostały zweryfikowane w skali przemysłowej. Wykonane odkuwki poddane były obróbce cieplnej do stanów T5 i T6 oraz cieplno-mechanicznej do stanów T8 i T9. Przeprowadzono analizę ewolucji struktury w zależności od rodzaju obróbki cieplnej. Określono właściwości mechaniczne i przewodność elektryczną odkuwek przeznaczonych na elementy napowietrznych linii energetycznych.
EN
The paper presents the results of research on the development of parameters for the manufacture of power transmission lines hardware from the modified EN AW-6101 alloy with the addition of Zr to replace the, widely used for this purpose, EN AW-6060, 2017 and 6082 alloys. The study was carried out on a semi-technical scale, and has been verified on an industrial scale. The produced forgings were subjected to heat treatment to the T5 and T6 condition and to thermo-mechanical treatment to the T8 and T9 condition. An analysis was carried out to determine structure evolution in relation to the heat treatment type. Mechanical properties and electrical conductivity of forgings for the overhead power lines were determined.
EN
This paper addresses the steady state analysis and the electromagnetic transients of overhead power transmission lines exhibiting corona. After a brief survey of the currently available modeling techniques, an alternative approach to the simulation of the corona discharge is presented. It is based on adding voltage-dependent current sources at prespecified nodes within the line’s lumped, ladder-shaped, equivalent circuit including an aduqate number of sections. The characteristics of these current sources can be determined using the usually available corona power loss measurements under power frequency sinusoidal voltage conditions. The line model is used for finding its transient response using time domain techniques. Several voltage excitation waveforms and magnitudes as well as different line’s loading conditions are investigated. As a further application of the suggested approach, the minimizion of the total corona losses of a long shunt compensated line will be considered as an additional criterion in the process of identifying the appropriate rating and location of the compensating coil primarily used for improving the line’s voltage profile.
11
Content available remote Electric and magnetic fields near new power transmission lines
EN
The article discusses electric and magnetic fields around new power transmission lines. The paper takes into considerations comparison of electric and magnetic fields near PTL with traditional AFL wires, traditional AFL wires with monitoring of temperature and HTLS wires.
PL
W artykule omówiono problematykę pola elektrycznego i magnetycznego wokół nowych linii elektroenergetycznych. Tekst uwzględnia zagadnienia: porównanie pola elektromagnetycznego w pobliżu PTL z tradycyjnych przewodów AFL, tradycyjne przewody AFL z monitorowaniem temperatury i HTLS.
PL
Zastosowanie w Polsce tymczasowych technik utrzymania zasilania energią elektryczną wymaga roztropnego, ale i odważnego umocowania prawnego. W obecnym stanie regulacji prawnych najlepszym rozwiązaniem wydaje się aktywne włączenie w nurt regulacji związany z wprowadzaniem Infrastruktur Krytycznych. Dobre rozwiązanie może uwzględniać zastosowanie tymczasowych technik nie tylko w stanach poawaryjnych, ale także tam, gdzie występuje obniżenie niezawodności i/lub podwyższone ryzyko dostawy energii elektrycznej.
EN
Application of temporary techniques for keeping the continuity of power supply in Poland needs wise, but at the same time courageous legal fixation. In the present state of legal regulations it seems to be the best solution to actively join the trend connected with introducing Critical Infrastructures. A good solution can take into account the application of temporary techniques not only in after-failure conditions, but also in cases when we deal with reliability decrease and/or a raised risk of electric power supply.
EN
Methods are presented for the cancellation of the power line’s magnetic and electric fields at pre-specified points close to the line corridor. For canceling the magnetic field, three auxiliary conductors constituting two mitigating loops are used. Their configuration should be geometrically similar to the arrangement of the 3-phase power line’s conductors, with respect to the point at which a zero magnetic field is required. A procedure is suggested for the optimal selection of the scaling factor relating the power conductors’ and the mitigating conductors’ geometrical dimensions. In a case study, the magnetic field reduction varies between 100% near the zero-field point to 35% to the right of that point, with an optimal scaling factor of 0.15. Similar procedure can be used for cance¬ling the electric field at a pre-specified point. The three auxiliary conductors should carry charges proportional to those on the active conductors, but of opposite signs. Results show that the field at the specified point will be exactly zero, instead of the original value of 2.6kV/m. The three voltages required to supply the auxiliary conductors are 76.62, 62.53 and 51.50kV, with almost equal phase angles. The fact that the potentials of the three auxiliary conductors are almost in phase suggests the possibility of using one transformer with appropriate taps to supply them.
PL
Przedstawiono wyniki oceny wpływu produktów spalania nośników energetycznych, lotnych substratów reakcji chemicznych i produktów termicznego rozkładu skał osadowych na stan techniczny konstrukcji wsporczych zlokalizowanych na terenie Energia Pro Zakład Energetycznego Opole SA, Rejon Sieci Wysokich Napięć. Ocenę wykonano w Katedrze Technologii Materiałów Budowlanych AGH w Krakowie.
EN
Presented are evaluation results of different fuels combustion products, chemical reactions volatile substrates and sedimentary rocks thermal decomposition products influence on technical state of power lines supporting constructions located on the site of Energia Pro Zakład Energetyczny Opole SA, High Voltage Network Area. The evaluation was carried out in the Building Materials Technology Department of AGH in Cracov.
PL
Przedstawiono założenia konstrukcyjne oraz doświadczenia wynikające z eksploatacji zespołu CZAZ-RL, przeznaczonego do zabezpieczania linii elektroenergetycznych WN pracujących w sieci z bezpośrednio uziemionym punktem zerowym.
EN
Design data and experience resulting from the use of the CZAZ-RL unit intended for protection of high-voltage power transmission lines operating in a network with directly grounded neutral.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.