Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  power system defence
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The basic measure of the power system defence against sudden imbalance due to generation deficit is the Automatic Frequency Load Shedding (AFLS). Every transmission system operator (TSO), to whom the NC ER/2017 code applies, shall be obliged to use in their defence plan the AFLS automation that meets the guidelines set out there. In the simulation tests carried out using the DAKAR program, the AFLS was modelled in accordance with the guidelines of NC ER/2017 and the current requirements of the Transmission Network Code (IRiESP). The selected area concerned the northwestern part of the National Power System with a large imbalance and a sudden decrease in frequency. Advantages of NC ER/2017 entries have been pointed out.
PL
W planie obrony systemu elektroenergetycznego przed nagłym niezbilansowaniem, związanym z deficytem mocy generacyjnej, jako podstawowy środek obrony stosuje się automatykę samoczynnego częstotliwościowego odciążania (SCO). Każdy z opera- torów systemów przesyłowych (OSP), którego dotyczy NC ER/2017, jest zobowiązany do stosowania w swoim planie obrony automatyki SCO spełniającej podane w kodeksie wytyczne. W badaniach symulacyjnych, przeprowadzonych za pomocą programu DAKAR, zamodelowano automatykę SCO zgodnie z wytycznymi NC ER/2017 oraz dotychczasowymi wymogami Instrukcji Ruchu i Eksploatacji Sieci Przesyłowej (IRiESP). Wydzielany obszar dotyczył północno-zachodniej części KSE z dużym niezbilansowaniem i nagłym spadkiem częstotliwości. Wskazano zalety zapisów NC ER/2017.
EN
In a paper presented at the previous APE ‚13 conference [1] results of a concept of separating an island system with a BC50 thermal unit in VEOLIA ENERGY Poznan ZEC SA’s power plant (hereinafter ECII Karolin) were presented. The following loads were selected for supply in the separated island system: EC II Karolin’s auxiliaries and general purpose loads, industrial loads in the plant’s immediate vicinity, and, in the future, municipal consumers. The concept of separation of the island supplied from BC50 unit requires comprehensive verification of the adopted assumptions through system experiments before the appropriate separation automation implementation. The paper presents selected results of the first experiment of the operation of the separated island system with a BC50 unit and the plant’s auxiliaries and general purpose loads plus an external consumer, i.e. a waste water treatment plant in the conurbation of Poznań.
PL
W artykule prezentowanym podczas poprzedniej konferencji APE ’13 [1] przedstawiono wyniki koncepcji wydzielania układu wyspowego z blokiem ciepłowniczym BC50 w elektrociepłowni VEOLIA ENERGIA Poznań ZEC SA (dalej ECII Karolin). W wydzielonym układzie wyspowym przewidziano do zasilania następujące odbiory: potrzeb własnych i ogólnych EC II Karolin, zakładów przemysłowych zlokalizowanych w bezpośrednim sąsiedztwie elektrociepłowni, a także w przyszłości odbiorców komu- nalnych. Koncepcja wydzielania układu wyspowego zasilanego z bloku BC50 wymaga, przed wdrożeniem odpowiedniej automa- tyki wydzielania, wszechstronnego sprawdzenia poprzez przeprowadzenie eksperymentów systemowych weryfikujących przyjęte założenia. W artykule przedstawiono wybrane wyniki pierwszego eksperymentu pracy wydzielonego układu wyspowego z blokiem BC50 i odbiorami potrzeb własnych i ogólnych elektrociepłowni oraz zewnętrznego odbiorcy – oczyszczalni ścieków aglomeracji poznańskiej.