This paper presents a novel adaptive hysteresis current control based on interval type2 fuzzy logic for active power filter to eliminate harmonics and compensate for reactive power. A new method to generate reference compensating current for the fundamental active current component is also proposed using the recursive discrete Fourier transform. The switching frequency of the conventional fixed hysteresis band (HB) control during the fundamental period is varied; thus causing harmonic ripple of the load current. This problem can be solved using adaptive HB control strategy. In this study, a fuzzy logic controller is used for base control because of its advantages over other adaptive HB techniques, such as mathematical simplicity, ease in adding heuristic knowledge, and robust changes in system operating conditions. An interval type2 fuzzy-adaptive HB technique is utilized for the current control to enhance the switching signals produced by the voltage source inverter. Based on the supply voltage and the slope of the reference current, this controller changes the hysteresis bandwidth. To control the DC capacitor voltage, an interval type2 fuzzy logic based controller is developed. Simulation results of the shunt active power filter with an interval type2 fuzzy adaptive HB current controller are examined and compared with the conventional controller. The results verify the effectiveness of the proposed controller in reducing total harmonic distortion from 21.03% to 2.12% and reactive power from 2616 Var to 6.28Var.
PL
Zaprezentowano nową metodę adaptacyjnego sterowanie prądem w celu eliminacji harmonicznych i kompensacji mocy biernej. Wykorzystano aktywny filtr bazujący na logice rozmytej typu 2. Stosuje się adaptacyjne histerezowe sterowanie w celu poprawy sygnału przełączania wytwarzanego przez przekształtnik napięciowy. Sterownik zmienia szerokość histerezy bazując na wartości napięcia zasilaniam i szybkości zmian pradu. Zmniejszono zawartość harm onicznych z 21% do 2 % i moc bierna z 2616 Var do 6,3 VAR.
EN
In recent years, multilevel technology has become an effective and practical solution for moderate and high voltage application field. In all multilevel technology, cascade multilevel inverters have become the major circuits used in power quality conditioners. Evidently,the voltage balancing problem of DC capacitors of cascade inverters is a key problem to the power quality conditioners. This paper mainly focuses on exploring the hypostasis of various voltage balancing control methods. A comprehensive theoretical analysis of voltage balancing control fundament is presented. The issue of voltage balance is discussed from output pulses of H-bridge inverters point of view, and a model for analyzing the charge and discharge process of H-bridge DC capacitor is established. Furthermore, all regulation means of output pulses of H-bridge inverters for redistributing active power is reported and quantified. The simulation results illustrate that the research is satisfactory.
PL
Zaprezentowano teoretyczną analizę sterowania jakością napięcia w kaskadowo połczonych przekształtnikach mostkowych typu H. Przeanalizowano proces ładowania i rozładowania kondensatora. Przedstawiono badania i symulacje na przykładzie kondycjonera jakości energii.
3
Content available remote Power Quality Conditioners with Minimum Number of Current Sensors Requirement
EN
The paper introduces power quality conditioners with minimum number of current sensors. The power balance method for active conditioners control is introduced as well. Some investigation results of implemented solution are depicted to prove effectiveness of proposed arrangements.
PL
Artykuł przedstawia układy kondycjonowania energii z minimalną liczbą czujników prądu. Opisana została metoda bilansowania mocy czynnej wykorzystywana do sterowania tymi układami. Zamieszczone zostały także wyniki badań dowodzące efektywności proponowanych rozwiązań.