1
Content available remote Moving average signals for the static compensator control
EN
The shunt static compensator with the control based on the average signals is presented. Two control signals are considered - moving RMS value of grid voltage and moving average power of the energy source. The compensator generates reactive current computed in the real time with the use of the iterative method. The multiport representation of the grid is presented. Analytical and simulation results show how the iterative control of the compensator behaves for three kinds of control signals.
PL
Opisano sterowanie kompensatora statycznego z wykorzystaniem dwóch rodzajów sygnałów – przesuwnej wartości skutecznej napięcia sieci i przesuwnej mocy czynnej źródła energii. Kompensator generuje prąd bierny obliczany w czasie rzeczywistym z wykorzystaniem metody iteracyjnej. Pokazano wielowrotnikową reprezentację sieci elektrycznej. Analityczne i numeryczne wyniki pokazują jak przebiega sterowanie iteracyjne dla dwóch rodzajów sygnałów sterujących.
PL
W artykule przedstawiono model wyznaczania obciążeń oraz obliczania rozpływów mocy w sieci terenowej SN, którego zastosowanie nie wymaga obszernych danych wejściowych. Zaprezentowano charakterystykę odbiorców energii elektrycznej, którzy są zasilani z sieci terenowej niskiego i średniego napięcia wraz z krótką informacją na temat tych sieci. Omówiono metody mające zastosowanie do wyznaczania prognozy średnioterminowej obciążenia terenowych stacji transformatorowych SN/nn. Działanie modelu zobrazowano poprzez przykład obliczeniowy rocznych obciążeń wybranych terenowych stacji wraz z symulacją rozpływów w latach 2012-2019. Przeprowadzono analizę otrzymanych wyników obliczeń z danymi rzeczywistymi.
EN
The article presents a model for determining loads and calculating power flows in the MV rural distribution network, the use of which does not require extensive input data. It presents the characteristics of electricity consumers, supplied from LV and MV rural distribution network, along with a brief information on these networks. The methods used to determine the medium-term load forecast of MV/LV rural stations were discussed. The model functionality was illustrated by a calculation example of the annual loads of selected rural stations, along with the flow simulation in 2012- 2019. The comparative analysis was made based on actual data.
EN
Calculating shift factor (SF) with power injection is essential for dispatch demand network analysis. Similarly, load profile simulation in an electrical power flow network is essential to determine powers and voltages transmission in the network. Many available specialized commercial software packages for this purpose are expensive and licensed. The purpose of this paper is to present the solution of the above two mentioned problems simply and in readily available Microsoft Excel Visual Basic Applications (VBA) Macros. Efforts are made here not to describe the theory behind electrical dispatch demand and power flow networks, but to describe VBA Macro programming for this purpose. Further, the website link for the application program is provided for teaching, learning, and expansion of the program.
PL
Obliczanie współczynnika przesunięcia (SF) z podaniem mocy jest niezbędne do analizy sieci zapotrzebowania na wysyłkę. Podobnie symulacja profilu obciążenia w sieci przepływu energii elektrycznej jest niezbędna do określenia transmisji mocy i napięć w sieci. Wiele dostępnych specjalistycznych komercyjnych pakietów oprogramowania do tego celu jest drogich i licencjonowanych. Celem tego artykułu jest przedstawienie rozwiązania powyższych dwóch problemów w sposób prosty iw łatwo dostępnych makrach Microsoft Excel Visual Basic Applications (VBA). Podejmowane są tutaj wysiłki, aby nie opisywać teorii stojącej za zapotrzebowaniem na przesył energii elektrycznej i sieciami przepływu mocy, ale aby opisać w tym celu programowanie VBA Macro. Ponadto udostępniono łącze internetowe do programu użytkowego umożliwiające nauczanie, uczenie się i rozszerzanie programu.
EN
The aftermath of including new technologies in a modern electric system in conjunction with the incessant rise in power demand could pose a risk to the optimal operation of the system. Therefore, it becomes imperative to identify the most influential and critical nodes of such a system to avert future problems in network operation. In this paper, to identify most significant nodes of the system, the authors propose two measures of centrality in accordance with the network structural properties of a power system, namely, degree centrality (DC) and eigenvector centrality (EC). These are expressed considering the admittance matrix that exists among the interconnection of load to load nodes in an electrical power network. A critical node closeness centrality (CNCC) method is also proposed to identify critical nodes of the system. This is done by modifying the conventional closeness centrality (CC) to include the influence of interconnection that exists between network load to load nodes as captured by the admittance matrix between them. A comparative analysis of the proposed techniques with other conventional methods is also carried out. The result of the simulation shows that the proposed methods could serve as alternative tools in the identification of influential and weak nodes in a power system.
EN
During the operation of industrial supply power systems, sometimes it becomes desirable paralleling transformers, the characteristics of which do not quite correspond to such a procedure. When transformers are connected in parallel, any difference between their parameters causes the load to be redistributed between them compared to the previous operating mode they had been running separately. The paper deals with the problem of different capacity transformers paralleling within a mine power supply system.
PL
Podczas pracy przemysłowych systemów zasilania pożądana jest czasami równoległa praca transformatorów, których charakterystyki nie są w pełni przystosowane do takich warunków. Gdy transformatory są połączone równolegle, każda różnica pomiędzy ich parametrami powoduje zmianę ich obciążenia w porównaniu z indywidualną pracą każdego z nich. W artykule omówiono problematykę równoleglej pracy transformatorów różnej mocy w systemie zasilania kopalni.
EN
This study was aimed to present a Technical loss analysis of the Provincial Electricity Authority (PEA) in Hatyai. To determine the technical loss in the distribution system included are Transmission Line Losses, Power Transformer Losses, Distribution Line Losses and Lowvoltage Transformer and Distribution Line Losses. It was found that Low-voltage Transformer and Distribution Line Losses had a maximum value of 79 % and Technical loss was at 3.43. So in controlling or decrease Technical loss, the appropriate and correct method had to be selected by investigating both cost and worth. This study was also to determine distribution line losses by electrical model and to report on the power losses evaluation method as an improvement method to reduce the investigation cost for both transformer and capacitor selection. The study further aims at increasing the efficiency and reliability of the distribution system by reducing Technical Losses by increasing feeder size, power factor correction, reducing feeder impedance, lower transformer losses. It was discovered that line losses have much value at the end line. This was found to decrease when loads have constant distribution and are near the source. That is, line losses have lower value when lead lines have a larger size. Both load distribution and lead line sizes were observed to affect distribution line losses.
PL
Niniejsze opracowanie miało na celu przedstawienie analizy strat technicznych Urzędu Prowincji Energii Elektrycznej (PEA) w Hatyai. W celu określenia strat technicznych w systemie dystrybucyjnym uwzględnia się straty linii przesyłowej, straty transformatora mocy, straty linii dystrybucyjnej oraz straty transformatora niskiego napięcia i linii dystrybucyjnej. Stwierdzono, że straty transformatora i linii rozdzielczej niskiego napięcia miały maksymalną wartość 79%, a straty techniczne 3,43.. Badanie to miało również na celu określenie strat linii rozdzielczych za pomocą modelu elektrycznego i przedstawienie metody oceny strat mocy jako metody poprawy w celu zmniejszenia kosztów badania zarówno doboru transformatora, jak i kondensatora. Ponadto badanie ma na celu zwiększenie wydajności i niezawodności systemu dystrybucyjnego poprzez zmniejszenie strat technicznych poprzez zwiększenie rozmiaru zasilacza, korekcję współczynnika mocy, zmniejszenie impedancji zasilacza i zmniejszenie strat transformatora. Stwierdzono, że straty linii mają dużą wartość na linii końcowej. Stwierdzono, że zmniejsza się to, gdy obciążenia mają stały rozkład i znajdują się blisko źródła. Oznacza to, że straty linii mają mniejszą wartość, gdy linie prowadzące mają większy rozmiar. Zaobserwowano, że zarówno rozkład obciążenia, jak i rozmiary linii ołowianych wpływają na straty w linii dystrybucyjnej.
PL
System elektroenergetyczny wymaga stałego nadzoru oraz działań regulacyjnych, które umożliwiają bezprzerwowe zasilanie odbiorców energią elektryczną o zestandaryzowanych parametrach. W bieżących warunkach pracy dotychczasowe środki regulacyjne stosowane w KSE okazują się niewystarczające, co powoduje konieczność poszukiwania nowych i skutecznych metod regulacji. Jedną z możliwości jest wykorzystanie transformatorów z regulacją wzdłużno-poprzeczną do sterowania przepływami mocy czynnej oraz utrzymania poziomów napięć w węzłach sieci. W artykule przedstawiono wykorzystanie transformatorów regulacyjnych w działaniach operatorskich.
EN
The power system requires constant supervision and regulatory actions that enable uninterrupted supply of electricity to consumers with standardized parameters. In the current working conditions, the existing regulatory measures applied in the PPS turn out to be insufficient, which makes it necessary to search for new and effective methods of regulation. One possibility is to use special regulating transformers to control active power flows and to maintain voltage levels in the network buses. The article presents the use of regulating transformers in an operator activities.
EN
The work is intended to extend the application of a smart transformer on a radialdistribution system. In this paper, an updated algorithm on the backward/forward powerflow is introduced. The so-called direct approach of power flow is employed and analyzed.In addition, the paper focused on integrating a smart transformer to the network and solvingthe updating network also using the direct approach load flow. The solution of the smarttransformer using the direct approach power flow method is quite straightforward. Thismodel is applied to radial distribution systems which are the IEEE 33- and IEEE 69-bussystems as a case study. Also, the paper optimizes the best allocation of the smart transformerto reduce the power losses of the grid.
PL
Metoda HELM (Holomorphic Embedding Load Fload Method) jest całkowicie nową metodą rozwiązywania równań opisujących stany ustalone systemów elektroenergetycznych. Działanie metody oparte jest o wykorzystanie technik analizy zespolonej. Jednak najważniejszą jej cechą jest to, że jeżeli rozwiązanie istnieje, wówczas odpowiada rzeczywistemu stanowi pracy systemu. Natomiast gdy rozwiązanie nie istnieje, wówczas jednoznacznie sygnalizuje że wystąpi lawina napięcia (blackout). Artykuł jest pierwszą prezentacją metody HELM. Pokazuje jej główne założenia i sposób odwzorowania podstawowych elementów modelu systemu elektroenergetycznego. Dokonuje również porównania obliczeń z wykorzystaniem metody HELM z klasycznymi metodami iteracyjnymi.
EN
HELM (Holomorphic Embedding Load Flow Method) is a novel method for calculation the power flow equations of power systems. It based on the techniques of Complex Analysis. HELM is non-iterative and deterministic method, yielding the correct solution when it exists and, conversely, unequivocally signaling voltage collapse when it does not. The article is the first presentation of the HELM method. It shows its main assumptions and the way of creation the basic elements of the power system model. Author compares the calculations using the HELM method with classic iterative methods.
EN
Based on current developments related to the application of technology and the growth of load demand, power system structure (PSS) has grown into a large, intelligent network by integrating many new systems. At present, many classical systems are being modernized and developed towards smart systems to various technical performances while providing continuously energy from the generating sites to serve load centres as end energy users. On the other hand, protection and attention to the environment and renewable energy sources also affect the power system operation which is intended to reduce emissions and include green energy sources. Furthermore, these works explore an assessment of operations on local interconnection system topologies which are installed captive power plants. These studies are used to develop and evaluate the performance, where solar power plants are also installed as sources of energy suppliers. In this study, operating assessments are approached using a power flow study (PFS) to define structural performance expanded through several scenarios. In addition, the procedure for obtaining optimal conditions is also facilitated by using the Takagi Method (TM) and Thunderstorm Algorithm (TA) for PFS hybrid structures considered an integrated renewable energy source (IRES). Based on the technical scenario set, the results show that the applied scenarios have different performances. In addition, this study also provides various implications. IRES has affected system performance. PSS contributes to the part that is committed to covering the burden. TM and TA can be applied to the hybrid PFS structure.
PL
W artykule przedstawiono metodę PFS (power flow study) do optymalizacji struktury lokalnej sieci zasilającej z zainstalowanymi źródłami fotowoltaicznymi. Zastosowano też metodę Takagi i algorytm burzowy do optymalizacji sieci z różnymi scenariuszami.
11
Content available remote Load flow analysis in local microgrid with storage
EN
This paper deals with load flow analysis of local microgrid containing a stochastic renewable energy source and storage. The study is carried out using the Matpower toolbox with all relevant constraints considered regarding storage, power lines and other components. Certain operational scenarios of the microgrid are also discussed.
PL
Niniejszy artykuł dotyczy analizy rozpływu mocy w lokalnej mikrosieci zawierającej stochastyczne odnawialne źródło energii i magazynowan energii. Analizę przeprowadzono przy użyciu zestawu narzędzi Matpower ze wszystkimi istotnymi ograniczeniami w odniesieniu do magazynu energii, linii energetycznych i innych komponentów. Omówiono również niektóre scenariusze operacyjne mikrosieci.
EN
The present article shows the results of an analysis of active power consumed by AC arc furnace at various stages of the melting process, taking harmonics into consideration. The analysis was based on measurement data in the form of computer recorded voltage and current waveforms in the power circuit of the arc furnace. Next the frequency analysis and the evaluation of the content harmonics of recorded waveforms were performed. Computation made using the fast Fourier transform FFT built-in in MATLAB. The active power of the arc furnace was determined on the basis of the classical theory of harmonic power distributions and instantaneous power after Clarke transformation to the orthogonal coordinate system α-β. Harmonic distribution phase currents and voltages were transformed using the FFT procedure, as well as distorted voltage/current waveforms registered as a sequence of samples. The obtained results demonstrate a high level of compatibility between the instantaneous power and active power for the methods under consideration.
PL
W artykule przedstawiono wyniki analizy mocy czynnej pobieranej przez piec łukowy AC w różnych etapach procesu wytopu z uwzględnieniem wyższych harmonicznych. Do analizy wykorzystano dane pomiarowe w postaci zarejestrowanych komputerowo przebiegów napięć i prądów w torze zasilania pieca łukowego. Następnie przeprowadzono analizę częstotliwościową i ocenę zawartości wyższych harmonicznych zarejestrowanych przebiegów. Obliczenia wykonano za pomocą szybkiej transformacji Fouriera FFT w programie MATLAB. Moc czynną pieca łukowego wyznaczono w oparciu o klasyczną teorię mocy dla rozkładów harmonicznych oraz na podstawie mocy chwilowej po transformacji Clarke’a do układu ortogonalnych współrzędnych α-β. Transformacji poddano uzyskane w procedurze FFT rozkłady harmoniczne prądów i napięć fazowych, a także zarejestrowane w postaci ciągu próbek odkształcone przebiegi napięciowo-prądowe. Uzyskane wyniki wykazują dużą zgodność mocy chwilowej i mocy czynnej dla rozpatrywanych metod.
EN
P-V curve and V-Q curve (often term as Q-V curve) are widely used for planning and operation studies. The P-V curve and V-Q curve of an unbalanced three-phase system, unlike the balanced three-phase system, may not have similar loading margin (LM) and reactive power margin (RPM) on each phase. Therefore, DIgSILENT Programming Language (DPL) has been used to study the maximum loading point (MLP), critical point (CP), and also minimum reactive power point (MRPP) on each phase of an unbalanced three-phase system with different static loads. The tracing direction of P-V curve of each phase and the LM and RPM of each phase obtained from the P-V curve and V-Q curve for different static loads are also discussed. On top of that, continuation power flow (CPF) has become a common method to study the MLP. Hence, a simple 2-bus balanced three-phase system is used to validate the result obtained from the DIgSILENT with CPF method.
PL
Krzywe P-V I V-Q w systemie trójfazowym niezrównoważonym mogą nie mieć tego samego marginesu obciążenia LM i marginesu mocy biernej RPM w każdej z faz. Zastosowano język programowania DIgSILENT do określenia maksymalnego punktu obciążenia MLP, punktu krytycznego CP i punktu minimalnej mocy biernej MRPP.
PL
Transformatory z regulacją wzdłużno-poprzeczną pozwalają na kształtowanie zarówno poziomu, jak i kąta napięcia. Daje to możliwość regulacji parametrów stanu układu przesyłowego, a w efekcie wpływa na zmianę rozpływu mocy (w tym mocy czynnej) w sieciach elektroenergetycznych. W artykule przedstawiono ideę regulacji wzdłużno-porzecznej oraz model zespołu transformatorowego. Wykorzystując model sieciowy zespołu transformatorowego przeprowadzono analizy sieciowe skupione na ocenie możliwości sterowania rozpływem mocy. Dla wybranego zespołu transformatorowego przedstawiono wyniki wykonanych obliczeń.
EN
The functioning of the power transmission system is the result of using, among others, devices for the transmission and transformation electricity. Proper operation and control of these devices allows to maintain the correct parameters and continuity of electricity supply to final customers. In the group of devices of electricity transformation it can be distinguished from control transformers that have the ability to shape both the magnitude and the angle of voltage. In this way, it can be adjusted state parameters of power system allow the selection of the size of active and reactive power transmission. This property lets they provide a potential opportunity to influence the power load flow (including active power) in electric power networks. The paper is presented a problem of phase-angle voltage control in power system and model of such a transformer unit. The presented transformer unit model are used for power network calculation, especially to power flows control. It was prepare some power flows cases in high voltage networks. There is presented results of power flow system study with using the voltage angle control of such transformer units.
EN
This paper investigates the use of iterative linear methods applied to the power flow problem (PFP) solution in power systems. Preconditioning techniques are studied and incorporated to the methodology to solve a linear system. As application to the PFP, four iterative linear techniques and a direct method are evaluated and their performances are compared. Numerical experiments demonstrate the effectiveness of the proposed methodology, suggesting the good performance of the Bi-conjugate Gradient Stabilized (BiCGStab) as an adequate iterative linear method for the applicability in the solution of a PFP.
PL
W artykule analizowano metodę iteracyjną zastosowaną do kontroli przepływów mocy. Zbadano cztery liniowe techniki iteracyjne i metodę bezpośrednią Najlepsze właściwości wykazała technika Bi-conjugated Gradient Stabilized BiCGStab.
PL
W artykule zostały przedstawione wybrane zagadnienia dotyczące wyznaczania obciążeń oraz rozpływów mocy w sieci terenowej SN. Omówione zostały dwie użyteczne metody określania obciążeń szczytowych stacji SN/nn (deterministyczna, probabilistyczna) oraz dwie metody obliczania rozpływów mocy w sieci średniego napięcia (szacowania obciążeń, współczynnika jednoczesności). Zaprezentowano przykład obliczeniowy dla wybranego fragmentu sieci terenowej.
EN
The article presents selected issues concerning the determination of loads and power flow in the MV rural distribution network. It discusses two useful methods for determining peak loads of MV/LV stations (deterministic, probabilistic) and two methods for power flow calculation in medium voltage grids (load estimation and simultaneity factor). An example of a calculation for the chosen part of the rural network is shown.
17
Content available remote Impact of Loads on Power Flow in Power Systems Using PowerApps and ETAP
EN
This paper presents a study of the impact of loads on power flow in power system. It deals with the impact of both the voltage nodes and the transmission of active and reactive power in lines, and therefore the loss of active and reactive power in the system. Flexible Alternating Current Transmission System (FACTS) devices are found to be encouraging in improving voltage stability limit in power systems. This paper investigates the application of FACTS devices (Static Var Compensator, SVC) on a 9-bus multimachine power system, it deal with the line losses and improving voltage stability limit. Amount of increased reactive power generation and line losses are taken as indicators of stressed conditions of a power system. The use of SVC is identified by PowerApps and ETAP software packages. Both software are used for IEEE 9 bus test system and the results obtained are presented and interpreted.
PL
Analizowano wpływ napięć w węzłach i przepływ mocy biernej i czynnej na pracę systemu energetycznego. Artykuł przedstawia badania zastosowania urządzeń FACTS w dziewi1)ęcioszynowym, wielomaszynowym systemie. Wykorzystano oprogramowanie ETAP.
18
Content available remote First-Order Sensitivity Applied in Power Distribution System
EN
This paper presents a study of the power distribution system via sensitivity analysis. This study is based on first-order sensitivity analysis applied in the power flow (PF) solution. Unlike the PF algorithm, this technique does not require an iterative process, which results in a faster methodology with high accuracy and greatly reduced computational work. Starting from a known PF solution, considered as the base case, the new operating point is calculated directly after making a perturbation in the loads. The methodology analysis is applied to 34, 70 and 476-bus distribution power systems. Test results demonstrate the efficiency of the approach.
PL
W artykule przedstawiono metodę kontroli dystrybucji mocy za pośrednictwem analizy czułości (analiza czułości pierwszego rzędu). Dzięki tej metodzie uzyskuje się szybsze rezultaty unikając procesu iteracji. Startując ze znanego rozwiązania rozpływu mocy PF nowy punkt pracy jest obliczany po zmianie obciążeń.
PL
W ostatnich latach wpływ systemów sąsiednich na pracę systemu polskiego stał się znaczący. Wynika to głównie z silnego wzrostu nieplanowych międzysystemowych przepływów mocy czynnej, które stają się istotnym problemem dla polskiego operatora systemu przesyłowego, ale także dla operatorów systemów Czech, Słowacji i Węgier. Jednym z możliwych sposobów pozwalających na ograniczenie tego zjawiska jest zastosowanie przesuwników fazowych. Są to transformatory specjalnej konstrukcji, które służą do regulacji kąta obciążenia (fazy napięcia) i tym samym do regulacji przepływu mocy czynnej w sieci przesyłowej. Artykuł przedstawia wybrane wyniki badań dotyczących wpływy przesuwników fazowych instalowanych na granicy Polska – Niemcy i Czechy – Niemcy na transgraniczne przepływy mocy, w tym na możliwości ograniczenia przepływów nieplanowych w rejonie Europy Środkowo-Wschodniej. Analizy zostały przeprowadzone dla różnych stanów pracy systemu połączonego.
EN
An impact of neighbouring electric power systems on operation of Polish electric power system is becoming more and more important in recent years. This fact results mainly from considerable increase of unplanned flows of active power among national power systems, what becomes a real problem for Polish transmission system operator as well as for Czech, Slovakian and Hungarian ones. One of possible ways that enables to limit this phenomenon is the use of phase shifters. Phase shifters are special transformers that enable to control the power angle, that is, to control the flow of active power in transmission grid. This paper presents selected results of research into an impact of phase shifters installed on Polish-German border and on Czech-German border on cross-border electric power flows, including possibilities for limiting unplanned power flow in the Central and Eastern Europe region. Analyses were carried out for different operating states of interconnected system.
EN
Advanced power electronic converters can provide the means to control power flow and ensure proper and secure operation of the future power grid. The small electrical energy sources dispersed in electrical power systems referred to as distributed generation are one of the most significant parts of future grids - Smart Grids. The threephase, direct matrix converter is an alternative solution to the conventional AC-DC-AC converter for interfacing two AC systems in distributed power generation with different voltage and/or frequency parameters. This paper presents a control analysis of a threephase matrix converter employed as a power interface of future electrical grids. The proposed system has been successfully tested for bidirectional power flow operation with different grid operating conditions, such as, frequency and voltage variation.