Content available Corrosion Resistance of X5CrNi18-10 Stainless Steel
EN
The paper presents the influence of heat treatment on the structure and corrosion resistance of X5CrNi18-10 steel. To determine the structure which has been obtained after heat treatment the methods of light and scanning electron microscopy with EDS microanalysis were used. The electrochemical corrosion properties of the investigated steel were studied in 3.5% NaCl solution using potentiodynamic polarization tests. Basing on the registered curves, the corrosion current, polarization resistance and corrosion potential were determined. The corrosion tests were followed by fractographic researches.
PL
Celem zrealizowanych badań była ocena odporności na korozję elektrochemiczną wyciskanego stopu magnezu AZ31 z dodatkiem 7,5% Li. Badania korozyjne realizowano w roztworach o stężeniu 0,01÷2,00 mol/dm3 NaCl. Próby potencjodynamiczne, które przeprowadzono, wykorzystując system do badań VoltaLab PGP201 firmy Radiometer, pozwoliły na rejestrację krzywych polaryzacji. Badania te wykazały, że wraz ze zwiększeniem stężenia molowego roztworu NaCl następuje pogorszenie właściwości korozyjnych. Za pomocą mikroskopu stereoskopowego Olympus SZX9 oraz skaningowego mikroskopu elektronowego Hitachi S-4200 przeprowadzono obserwację powierzchni stopu po próbach zanurzeniowych zrealizowanych w ciągu 1÷5 dni. Przed badaniami mikroskopowymi z powierzchni próbek usunięto produkty korozji w roztworze zawierającym 200 g/l CrO3 oraz 10 g/l AgNO3. Stwierdzono, że niezależnie od stężenia roztworu i czasu ekspozycji na powierzchni stopu są widoczne zmiany korozyjne. Dla większości próbek można zauważyć obszary objęte korozją nierównomierną. Ponadto stwierdzono występowanie korozji wżerowej. Wyniki zrealizowanych badań jednoznacznie wskazują na pogorszenie właściwości korozyjnych stopu wraz ze zwiększeniem stężenia molowego roztworu NaCl. Widoczny jest intensywny przebieg procesu korozyjnego, a intensywność ta rośnie wraz ze zwiększaniem stężenia roztworu oraz wydłużeniem czasu ekspozycji. Właściwości fizykochemiczne powierzchni oceniano metodą elektrochemicznej spektroskopii impedancyjnej. Pomiary przeprowadzono z wykorzystaniem systemu pomiarowego AutoLab PGSTAT 302N wyposażonego w moduł FRA2 (Frequency Response Analyser). Zarejestrowano wykresy Nyquista oraz Bodego. Przeprowadzone badania umożliwiły bezpośrednie porównanie zachowania się rzeczywistego obiektu z jego układem zastępczym, który jest modelem odnoszącym się do fizycznie realizowanej impedancji. Przyjęte struktury obwodów elektrycznych w obu przypadkach sugerują występowanie w badanych układach strefy wierzchniej, która charakteryzuje się dużą porowatością i dużym stopniem rozwinięcia powierzchni oraz przebiegu procesu korozyjnego przez dyfuzję reagentów. Zastosowanie przerobionego plastycznie stopu magnezu AZ31 z dodatkiem 7,5% Li w dużym stopniu jest uzależnione od odporności na korozję elektrochemiczną. Wyniki zrealizowanych badań jednoznacznie wskazują na małą odporność stopu w roztworach chlorków. Ze względu na dużą podatność stopów magnezu z litem na korozję elektrochemiczną jest zalecane stosowanie powłok chroniących przed oddziaływaniem agresywnego środowiska korozyjnego.
EN
The purpose of performed tests was evaluation of resistance to electrochemical corrosion of extruded magnesium alloy AZ31 with additive of 7.5% Li. Corrosion tests were performed in 0.01÷2.00 mol/dm3 NaCl solutions. Potentiodynamic tests, performed with application of testing system VoltaLab PGP201 by Radiometer, enabled to register polarisation curves. Potentiodynamic tests proved that increase of molar concentration of NaCl solution triggers deterioration of corrosion properties. With application of stereoscopic microscope Olympus SZX9 and scanning electron microscope Hitachi S-4200, the surface of the alloy was observed after immersion tests performed in 1÷5 days. Prior to microscopic tests, corrosion products in the solution containing 200 g/l CrO3 and 10 g/l AgNO3 were removed from the surface of the alloy. It was proved that irrespective of solution concentration and exposure time, there were visible corrosion modifications on alloy surface. Most samples feature non-uniform corrosion areas. Moreover, presence of pitting corrosion was proved. Results of performed tests prove explicitly deterioration of corrosion properties of the alloy with the increase of molar concentration of NaCl solution. It can be seen that corrosion process is intensive and that intensity increases with the increase of solution concentration and extension of exposure time. Physical and chemical properties of the surface were evaluated with application of electrochemical impedance spectroscopy. Measurements were made with measurement system AutoLab PGSTAT 302N equipped with FRA2 (Frequency Response Analyser) module. Nyquist and Bode diagrams were registered. Performed tests enabled direct comparison of behaviour of the real object with its equivalent system, which is a model referring to physically realised impedance. Adopted structures of electric circuits in both cases suggest presence of surface layer that features high porosity and high surface development level in the tested systems and the course of corrosion process through reacting substances diffusion. Application of magnesium alloy AZ31 with 7.5% Li additive after plastic forming is to a large extent dependent on resistance to electrochemical corrosion. The results of performed tests prove explicitly low resistance of the alloy in chloride solutions. Due to high susceptibility of magnesium alloys with lithium to electrochemical corrosion, it is recommended to apply layers protecting from aggressive corrosive environment impact.
PL
W pracy przedstawiono wyniki badań korozji elektrochemicznej wyciskanego stopu magnezu AZ31 z dodatkiem 7,5% Li. Badania realizowano w roztworach o stężeniu 0,01÷2 M NaCl. Odporność na korozję elektrochemiczną oceniano w oparciu o rejestrację krzywych polaryzacji anodowej metodą potencjodynamiczną. Wykonano obserwacje powierzchni po ekspozycji stopu w roztworach NaCl w czasie 1÷5 dni. Realizowane je przy użyciu mikroskopu stereoskopowego Olympus SZX9 oraz mikroskopu świetlnego Olympus GX51.
EN
The study presents results of electrochemical corrosion tests of extruded magnesium alloy AZ31 with addittion of 7,5% Li. The tests were performed in solutions with concentration of 0,01÷2 M NaCl. Resistance to electrochemical corrosion was evaluated on the ground of registered anodic polarisation curves with potentiodynamic method. The surface of the alloy was observed after exposure to NaCl solutions for 1÷5 days. The tests were performed with application of stereomicroscope Olympus SZX9 and light microscope Olympus GX51.
PL
W pracy przedstawiono wyniki badania odporności na korozję elektrochemiczną wyciskanego stopu magnezu AZ31 z dodatkiem 4,5% Li. Testy potencjodynamiczne wykonano w roztworach chlorków o stężeniu 0,01¸2 M NaCl. Na podstawie uzyskanych krzywych polaryzacji wyznaczono charakterystyczne wielkości opisujące odporność na korozję wżerową, tj.: potencjał korozyjny, opór polaryzacyjny, gęstość prądu korozyjnego. Przy użyciu mikroskopu stereoskopowego Nikon SMZ745T oraz mikroskopu świetlnego Olympus GX51 dokonano obserwacji powierzchni po ekspozycji stopu w roztworach NaCl w czasie 1¸6 dni. Na podstawie badań stwierdzono występowanie korozji wżerowej dla każdej z próbek wyciskanego stopu AZ31 z dodatkiem litu, niezależnie od czasu ekspozycji i stężenia roztworu.
EN
The study presents the results of resistance to electrochemical corrosion tests of extruded magnesium alloy AZ31 with 4,5% Li additive. Potentiodynamic tests were performed in chloride solutions with concentration of 0,01÷2 M NaCl. On the ground of obtained polarisation curves, typical features describing resistance to pitting corrosion were determined, i.e. corrosion potential, polarisation resistance, corrosion current density. Stereomicroscope Nikon SMZ745T and light microscope Olympus GX51 were used for observation of the surface of the alloy after exposure in NaCl solutions for 1÷6 days. On the ground of the tests presence of pitting corrosion was proved for each sample of extruded AZ31 with lithium additive, irrespective of the time of exposure and solution concentration.
PL
W pracy przedstawiono wyniki badania odporności na korozję elektrochemiczną wyciskanego stopu magnezu AZ31. W roztworach o stężeniu 0.01÷2 M NaCl zrealizowano testy potencjodynamiczne, które pozwoliły na uzyskanie krzywych polaryzacji anodowej. Przy użyciu mikroskopu stereoskopowego Olympus SZX9 oraz mikroskopu świetlnego Olympus GX51 dokonano obserwacji powierzchni stopu po ekspozycji stopu w roztworach NaCl w czasie 1÷5 dni. Wyniki badań potwierdziły obecność korozji wżerowej dla każdej z próbek wyciskanego stopu AZ31, niezależnie od czasu ekspozycji i stężenia roztworu.
EN
The study presents results of electrochemical corrosion resistance tests of extruded magnesium alloy AZ31. Potentiodynamic tests were performer in solutions with concentration of 0.01÷2 M NaCl that enabled to obtain anodic polarisation curves. With application of stereomicroscope Olympus SZX9 and inverted microscope Olympus GX51, surface of the alloy after exposure in NaCl solutions for 1÷5 days was observed. Test results confirmed presence of potting corrosion for each sample of the extruded alloy AZ31, irrespective of the time of exposure and solution concentration.
PL
Celem pracy jest zbadanie odporności na korozję elektrochemiczną szkła metalicznego Mg36,6Cu36,2Ca27,2 w stanie bezpośrednio po odlaniu oraz po wygrzewaniu. W ramach pracy przeprowadzono badania struktury analizowanych próbek za pomocą badań rentgenowskich i mikroskopowych. W celu określenia szybkości roztwarzania badanego stopu Mg36,6Cu36,2Ca27,2 oraz jego przydatności do potencjalnych zastosowań biomedycznych przeprowadzono badania immersyjne i potencjodynamiczne odporności na korozję elektrochemiczną w płynie fizjologicznym (wieloelektrolitowym). Stwierdzono, że stop Mg36,6Cu36,2Ca27,2 o strukturze amorficznej charakteryzuje się znacznie wyższą odpornością korozyjną od stopu Mg36,6Cu36,2Ca27,2 o strukturze krystalicznej.
EN
The aim of this paper is to investigate the electrochemical corrosion resistance of metallic glass Mg36,6Cu36,2Ca27,2 in as-cast state and after annealing. In the work was carried out studies of the structure of the analyzed samples using X-ray diffraction and microscopic observation. In order to determine the dissolution rate of the tested alloy Mg36,6Cu36,2Ca27,2 and potential suitability for biomedical applications were carried out immersion test and potentiodynamic test electrochemical corrosion in a physiological fluid (electrolyte solution). It was found that Mg36,6Cu36,2Ca27,2 alloy with amorphous structure has a much higher corrosion resistance than the same alloy with crystalline structure.
PL
W pracy przedstawiono badania mające na celu ocenę odporności na korozję elektrochemiczną przerobionego plastycznie metodą wyciskania stopu magnezu AZ80. Wykonano testy potencjodynamiczne i zanurzeniowe w roztworach o stężeniu 0,01÷2 M NaCl. Przy użyciu mikroskopu stereoskopowego Olympus SZX9 wykonano obserwacje powierzchni stopów po testach korozyjnych. Wyniki zrealizowanych badań jednoznacznie wskazują na pogorszenie właściwości korozyjnych stopu magnezu AZ80 wraz ze wzrostem stężenia molowego roztworu NaCl. Stwierdzono, że niezależnie od stężenia na powierzchni stopu występuje korozja wżerowa.
EN
The study presents tests that aimed at evaluation of resistance to electrochemical corrosion of magnesium alloy AZ80 after plastic working by means of extrusion. Potentiodynamic and immersion tests were performed in NaCl solutions with concentration of 0.01÷2 M. Observation of alloy surface after corrosion tests was made with application of stereoscopic microscope Olympus SZX9. Results of performed tests prove explicitly deterioration of corrosion properties of magnesium alloy AZ80 with the increase of molar concentration of NaCl solution. It was determined that pitting corrosion is present on the surface irrespective of concentration.
PL
W pracy przedstawiono wyniki badań wpływu wstępnego przygotowania powierzchni na odporność korozyjną stopu Ti6A/4V po zabiegu anodyzacji. Wstępne przygotowanie powierzchni obejmowało kombinację zabiegów: obróbki wibracyjnej, polerowania mechanicznego, piaskowania i polerowania elektrolitycznego. W celu określenia odporności korozyjnej stopu przeprowadzono badania potencjodynamiczne, wyznaczono stężenia jonów metalicznych przenikających do roztworu Ringera oraz dokonano obserwacji mikroskopowych powierzchni próbek.
EN
The paper presents results of initial surface treatment on corrosion resistance of Ti6AI4VELI alloy after anodizing process. The initial surface treatment consisted of the following processes: shot peening, mechanical polishing, sandblasting and electropolishing. In order to determine corrosion resistance of the alloy the following studies were carried out: potentiodynamic tests, concentration of released metallic ions as well as microscopic observations of sampies' surfaces.
PL
W pracy przedstawiono wyniki badań własności elektrochemicznych warstw węglowych wytworzonych na stali X39Cr13 oraz Cr-Nimo stosowanych na wyroby medyczne. Badane próbki poddano obróbce powierzchniowej obejmującej następujące procesy: bębnowanie, pasywację chemiczną oraz naniesienie warstwy węglowej. Warstwy węglowe nanoszono dwoma metodami RF PACVD oraz magnetronową. Dla oceny własności elektrochemicznych powłok przeprowadzono badania odporności korozyjnej metodą potencjodynamiczną oraz impedancyjną.
EN
The paper presents the results of the electrochemical properties of carbon coatings produced on steel X39Cr13 and Cr-Ni-Mo used in medical devices. The way of surface preparation of the samples contained barrel finishing, chemical passivation and carbon coatings by means of RF PACVD and magnetron methods. For the evaluation of electrochemical properties of coatings of corrosion resistance tests were carried out by means of potentiodynamic and impedance methods. (Study of electrochemical properties of carbon coatings used in medical devices).
PL
Celem pracy była ocena odporności na korozję w roztworach NaCl przerobionego plastycznie stopu magnezu WE43. Badania korozyjne realizowano w roztworach o stężeniu 0,01÷2 M NaCl przy użyciu systemu do badań elektrochemicznych VoltaLab®PGP201. Odporność na korozję elektrochemiczną oceniano opierając się na rejestracji krzywych polaryzacji anodowej metodą potencjodynamiczną. Wyniki zrealizowanych badań jednoznacznie wskazują na pogorszenie właściwości korozyjnych stopu magnezu WE43 wraz ze wzrostem stężenia molowego roztworu NaCl.
EN
The purpose of the study was to assess corrosion resistance of magnesium alloy WE43 after plastic working in NaCl solutions. Corrosion tests of WE43 alloy were carried out in solution with concentration of 0.01÷2 M NaCl with application of the system for electrochemical tests VoltaLab®PGP201. Resistance to electrochemical corrosion was evaluated on the ground of registered anodic polarization curves by means of potentiodynamic method. Results of all carried out tests explicitly prove deterioration of corrosion properties of magnesium alloy WE43 with the increase in molar concentration of NaCl solution.
11
EN
Purpose: The aim of the work was the evaluation of corrosion resistance and structure of aluminium AlMg2.5; AlMg5Mn and AlZn5Mg1 alloys. Design/methodology/approach: The corrosion resistance tests of investigated alloys were carried out by means of potentiodynamic method registering anodic polarization curves in 3.5% NaCl solution at room temperature. Registering anodic polarization curves was conducted at the potential rate equal to 1mV/s. As the reference electrode was used saturated calomel electrode (SCE) and the auxiliary electrode was platinum electrode. Mechanical properties were evaluated on the basis of Vickers hardness test. The test was realized with the use of Hauser hardness tester. The observations of the surface morphology after corrosive tests were carried out using Digital Scanning Electron Microscope DSM 940 OPTON. Findings: The investigations of corrosion resistance of examined aluminium alloys shows that the highest corrosion resistance in 3.5% NaCl solution was observed for AlZn5Mg1 aluminium alloy. Practical implications: The obtained results can be used for searching the appropriate way of improving the corrosion resistance of analysed alloys because better corrosion resistance, lightweight of aluminium and its alloys makes them as most attractive for the steel replacement in shipbuilding. Originality/value: The corrosion behaviour in chloride solution of AlMg2.5; AlMg5Mn and AlZn5Mg1 alloys was investigated.
12
Content available remote Crevice corrosion resistance of NiTi alloy after various surface treatments
EN
Purpose: The aim of the work was determination of crevice corrosion resistance of NiTi alloy after various surface treatments. Design/methodology/approach: The evaluation of the electrochemical behavior of NiTi alloy was realized by recording of anodic polarization curves with the use of the potentiodynamic method in the presence of a crevice former. Tests were carried out in Tyrode’s physiological solution. Findings: Surface condition of metallic biomaterial determines its corrosion resistance. In the course of the work it was observed that only ground samples showed no resistance to crevice corrosion. Suggested surface modifications ensure good crevice corrosion resistance. Practical implications: On the basis of the obtained results it can be stated that the suggested surface treatment can be applied for medical implants due to increase of the crevice corrosion resistance and in consequence increase of biocompatibility. Originality/value: The paper presents the influence of various methods of surface treatment on crevice corrosion resistance of the NiTi alloy. The suggested methods can be applied in treatment of the material intended for medical applications especially as reduced and complex shape implants (contact of metallic material with human body fluids in a small and occluded space).
13
Content available remote Corrosion resistance of NiTi alloy in simulated body fluids
EN
Purpose: Corrosion resistance of an implant alloy is a very important determinant of its biocompatibility. The nature of an environment and surface treatments have a significant influence on corrosion. Most of the knowledge on the corrosion behavior of NiTi is from studies of "standard" corrosion tests. In fact, the knowledge of the corrosion behavior of NiTi inside the body is very limited. The main aim of the research was evaluation of corrosion resistance of NiTi alloy in various simulated body fluids. Design/methodology/approach: The evaluation of the electrochemical behavior of NiTi alloy was realized by recording of anodic polarization curves with the use of the potentiodynamic method. The tests were carried out for differently modified surfaces in diverse simulated body fluids. Findings: Surface condition of a metallic biomaterial determines its corrosion resistance. In the course of the work the good corrosion resistance of all the tested samples (with different surface conditions) was observed. Research limitations/implications: The obtained results are the basis for the optimization of physicochemical properties of the NiTi alloy. The future research should be focused on selected specific implants specially with respect to their application features. Practical implications: On the basis of the obtained results it can be stated that the suggested surface treatment can be applicable for NiTi alloys due to the increase of the corrosion resistance. Originality/value: The paper presents the influence of various methods of the surface treatment on corrosion resistance of the NiTi alloy. The suggested surface treatment methods can be applied to implants intended for diverse medical applications, especially in cardiology and urology.