Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  post-tensioning
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Prestresssed concrete usage in church buildings construction in Poland
EN
restressed concrete was used to raise building constructions in Poland at the beginning of 1950s. Firstly, large span post-tensioned roof girders were made in industry halls, warehouses, airport hangars ....and so on, and also they were used to construct large capacity liquid tanks and bridges. The new form of post-tensioning, which means unbonded tendons, was used in buildings after 2000. Lately, the first time in Poland, prestressing has been used in project of two churches. As a result of using the unbonded tendons attractive forms were received. The slender prestressed slab supported on the steel “sapling” was constructed in the first of them. A prestressed concrete circumferential ring allows to create a delicate structure of timber girders in the second church. In this paper, these solutions are presented in detail together with the obtained benefits and proper calculation results.
PL
Istniejący w projektowaniu kościołów trend dążący do tworzenia delikatnych i smukłych form wymusza poszukiwanie nowoczesnych form konstrukcyjnych. Wobec powyższego po raz pierwszy w Polsce zastosowano cięgna sprężające bez przyczepności w projektach dwóch kościołów. W pierwszym z nich zaprojektowano smukłą płytę antresoli dla chóru, wspartą na stalowych podporach. W drugim zastosowano sprężony wieniec obwodowy. W pracy przedstawiono przyjęte założenia, wyniki analizy statyczno-wytrzymałościowej oraz szczegóły przyjętych rozwiązań konstrukcyjnych.
PL
W artykule przedstawiono stan awaryjny żelbetowej powłoki cylindrycznego zbiornika Wydzielonej Komory Fermentacyjnej (WKF) wynikający z błędów projektowych. Przeanalizowano wytężenie powłoki zbiornika występujące podczas nieudanej próby szczelności, zwracając szczególną uwagę na wytężenie zbrojenia poziomego. Etapy napełniania odwzorowano zgodnie z zaistniałym obciążeniem, jakie wystąpiło podczas przerwanej na skutek licznych przecieków, próby szczelności. Zaprezentowano zinwentaryzowany stan zarysowania powłoki cylindrycznej przy poziomie cieczy równym około 2/3 wysokości ściany. Ponadto przedstawiono analizę numeryczną oraz przebieg realizacji autorskiego projektu wzmocnienia żelbetowej ściany cylindrycznej zbiornika WKF przy użyciu cięgien bez przyczepności.
EN
The article presents damage of the ferro-concrete structure of a cylindrical tank of a separated fermenter. The damage results from design errors. Stress of the tank’s structure that was present during the unsuccessful tightness test was analyzed, with a particular emphasis placed on the stress imposed on the horizontal reinforcing elements. The stages of filling were replicated in line with the existing load that was present during the tightness test, interrupted due to the numerous leaks. The miniaturized status of the cylindrical surface, with the liquid leveled-off at the level of 2/3 of the total height of the wall was presented. What is more, a numerical analysis was presented, along with the process of realization of an original project, the aim of which was to reinforce the ferro-concrete cylindrical wall of the tank with the use of non-grip steel rods.
PL
Tematem pracy jest program badań doświadczalnych przeprowadzonych w ramach Polsko-Szwajcarskiego Programu Badawczego „TULCOEMPA” realizowanego przez Politechnikę Łódzką we współpracy ze szwajcarskim instytutem EMPA Swiss Federal Laboratories for Materials Science and Technology. Głównym celem projektu jest wzmocnienie istniejących belek mostowych przy użyciu naprężonych taśm kompozytowych CFRP z zastosowaniem innowacyjnej metody bezkotwowej aplikacji „gradientowej”. Badania doświadczalne przeprowadzone na replikach dźwigarów mostowych o długości 18,4m, wykonanych w rzeczywistej skali, potwierdziły skuteczność zaproponowanego wzmocnienia. Przyrost nośności kablobetonowego dźwigara po wzmocnieniu wyniósł 24% w porównaniu z elementem referencyjnym, osiągając przy tym o ponad 60% mniejsze ugięcia.
EN
The paper presents a research carried out within the framework of the Polish-Swiss “Tulcoempa” project, carried out by Lodz University of Technology and EMPA Swiss Federal Laboratories for Materials Science and Technology. The main goal of the project was to perform the first field application of an innovative, anchorless flexural strengthening with use of prestressed CFRP laminates on an existing bridge in Poland. Laboratory tests were conducted to verify the efficiency of the strengthening of two real-scale, 18.4m long, post-tensioned bridge girders reconstructed at EMPA institute. Flexural strengthening was successful and resulted in an increase of the member’s load capacity by 24% and reduction of the midspan deflection by more than 60%.
EN
Masonry is a complex composite material with non-linear material properties, which make the numerical investigation of its structural behaviour a difficult task. In this paper, a micro non-linear model created using a general purpose finite element code, is discussed with respect to its ability to simulate the in-plane behaviour of unreinforced masonry walls. That is, the capability of model in predicting the cracking, crushing, and sliding phenomena, as well as the global-orthotropic behaviour of previously tested masonry walls are examined. The model is then used within a parametric study to investigate the effect of different aspect ratios, vertical and horizontal post-tensioning as well as the effect of head joints on the capacity of the masonry walls. It will be shown that, while enhancing the lateral in-plane strength of the masonry walls, vertical post-tensioning can also reduce their ductility. On the contrary, horizontal post-tensioning can cause a small reduction in the initial stiffness and yielding shear force of the masonry walls, but increases their integrity, thereby preventing them from sliding and shear failure. Furthermore, it will be shown that, in spite of having a significant influence on local behaviour, head joints do not influence the global behaviour of the masonry walls.
PL
Mur jest złożonym materiałem kompozytowym o nieliniowych właściwościach, które powodują to, że ich analiza numeryczna jest złożonym i trudnym zadaniem. W artykule przedstawiono nieliniowy mikro-model stworzony przy użyciu uniwersalnego kodu elementów skończonych służący symulacji zachowania się niewzmocnionego muru w jego płaszczyźnie. Zbadano zdolność modelu do przewidywania występowania takich zjawisk jak pękanie, kruszenie, poślizg, tak jak we wcześniejszych badaniach ortotropowego zachowania się murów. Następnie model użyty został do badań parametrycznych wpływu pionowego i poziomego sprężania oraz wpływu kotew czołowych na nośność murów.
EN
Shape memory alloys (SMA) have been known for many decades. They are mainly used in medicine, electronics, air, and space industry and in the consumer goods industry. Examples are medical implants and instruments, cell phone antennas, frames for glasses, pipe couplings etc. The most usual SMA material on the market is nickel–titanium (Ni–Ti). Until today, SMAs have found very limited applications in civil engineering probably due to their cost and to limited knowledge of the material in the civil engineering industry. This paper presents existing applications, laboratory tests and new concepts of how to use shape memory alloys incorporated in energy dissipation devices, as well as for pre-stressing structures using SMA wires and for post stressing of existing structures using SMA tendons. Attempts to develop new generation of Iron based SMA for using in civil engineering structures will be presented as an alternative to existing high cost NiTi SMAs.
PL
Stopy z pamięcią kształtu znane są od wielu dziesięcioleci. Głównie są one wykorzystywane w medycynie, elektronice, przemyśle lotniczym i kosmicznym oraz w przemyśle towarów konsumpcyjnych. Przykładowo są to implanty i instrumenty medyczne, anteny telefonów komórkowych, oprawki okularów, złączki rurowe itp. Najbardziej typowym na rynku materiałem z pamięcią kształtu jest stop niklowo-tytanowy (Ni-Ti). Dotychczas stopy te miały bardzo ograniczone zastosowanie w budownictwie. Prawdopodobnie spowodowane to było kosztami i ograniczoną znajomością tego materiału w przemyśle budowlanym. W artykule tym przedstawiono istniejące zastosowania, badania laboratoryjne i nowe pomysły na wykorzystanie stopów z pamięcią kształtu będących częścią urządzeń rozpraszających energię, jak również w celu sprężania konstrukcji wykorzystując druty z tych stopów oraz sprężanie istniejących konstrukcji przy użyciu kabli wykonanych z takich stopów. Próby rozwijania nowej generacji stopów z pamięcią kształtu na bazie żelaza do wykorzystania w konstrukcjach budowlanych zaprezentowano jako alternatywę dla istniejących, drogich materiałów niklowo-tytanowych.
PL
W artykule przedstawiono informacje dotyczące elementów i konstrukcji sprężonych cięgnami bez przyczepności. Omówiono parametry mające wpływ zarówno na przyrost naprężeń w stali sprężającej, jak i nośność na zginanie elementu. Przedstawiono równania szacujące przyrost naprężeń zalecane przez różnych autorów. Pokazano wyniki trzech testów laboratoryjnych, które porównano z zaleceniami normowymi i teoriami naukowców zajmujących się powyższym zagadnieniem.
EN
In this paper there are presented some informations about members and structures prestressed with unbonded tendons. There are discussed parameters which influence both stress increase in prestressing steel and the flexural capacity of the member. Prediction equations for stress increase suggested by different investigators are demonstrated. There are shown results of three laboratory tests which are compared with codes recommendations and theories proposed by researchers dealing with the matter given above.
PL
Prezentowany artykuł opisuje pierwszą w Polsce realizację wzmocnienia żelbetowych belek konstrukcji nośnej dachu hali przemysłowej przez ich sprężenie taśmami kompozytowymi z włókien węglowych (CFRP). Podano opis konstrukcji budynku, wyniki badań stanu technicznego oraz sposób wzmocnienia. Skrótowo przedstawiona została technologia wykonania wzmocnienia.
EN
The paper gives a detailed description of the first implementation in Poland of strengthening of a reinforced concrete structure by prestressing with CFRP strips. The strengthened beams were part of an industrial hall roof support structure. A description of the building structure, the results of monitoring its technical state and the methods used to strengthen it are included in the article.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.