EN
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and the possibility of reuse of washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of washings drainage into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of washings from the analysed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. Washings were subjected to sedimentation and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
EN
This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.
PL
Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn.
PL
Przedstawiono ocenę fizykochemiczną oraz toksykologiczną próbek popłuczyn surowych (pobranych bezpośrednio po procesie płukania złóż filtracyjnych) po procesie napowietrzania oraz procesie dechloracji. Popłuczyny pobrano z obiegów basenowych dwóch krytych pływalni. Przeprowadzono badania wstępne i zasadnicze, w których popłuczyny charakteryzowały się zróżnicowanymi parametrami fizykochemicznymi. Do oceny toksykologicznej zastosowano test inhibicji bioluminescencji Mictorox®, test przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania wstępne obejmowały charakterystykę ekotoksykologiczną popłuczyn poddanych procesom napowietrzania oraz dechloracji. W badaniach zasadniczych analizowano wpływ czasu napowietrzania na jakość popłuczyn. Wyniki badań wstępnych wskazywały, że popłuczyny surowe, jak również po 30-minutowym napowietrzaniu nie mogły być bezpośrednio odprowadzone do środowiska naturalnego ze względu na wysoką toksyczność w stosunku do organizmów żywych. Zastosowanie dłuższego czasu napowietrzania (160 minut) przyczyniło się do znacznej poprawy jakości popłuczyn i eliminacji ich właściwości toksycznych w stosunku do organizmów wskaźnikowych. Zróżnicowane efekty uzyskano po procesie chemicznej dechloracji. Odnotowano stymulację bioluminescencji bakterii (testu Microtox®), ale równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem popłuczyn. Ze względu na zmienność jakości popłuczyn, obecność w nich ubocznych produktów dezynfekcji i koagulacji oraz toksyczne oddziaływanie na organizmy niezbędne jest rozszerzenie badań w zakresie metod umożliwiających ich recykling.
EN
This study discusses the physical and chemical analysis as well as toxicological evaluation of backwashings samples collected after rising raw filter beds, following aeration and dechlorination process. The tested washings were collected at facilities located in two indoor swimming pools. Toxicological evaluation included Mictorox® bioluminescence inhibition assay, Chaoborus sp. larvae survivability test as well as Lemna minor duckweed fito test. The initial stage of the research was focused on eco-toxicological properties of backwashings, subject to aeration and dechlorination processes. The main stage of the research involved additional analysis of the impact of aeration duration on the quality of washings in terms of physical and chemical parameters. The results of the initial stage clearly suggest that both raw washings as well as washings after 30 minutes of aeration are not suitable for direct disposal in the environment due to biohazards resulting from high toxicity of washings. On the other hand extension of the aeration process (160 minutes) contributed to significant improvement of washings quality and removal of toxic properties in relation to the indicator species used in the research. Chemical dechlorination ended with varying results. Microtox® bioluminescence assay resulted in bacteria bioluminescence with simultaneous observation of death of individual larvae. Despite high increase of biomass in Lemna minor test, some gradual decolouration of shoots as the result of washings used. In further solutions for recycling must be sought which will provide reduced water consumption and sewage.
PL
Przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu: koagulacja-sedymentacja-nanofiltracja do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5-3,0 mg Al/dm3) oraz sedymentacji (przy czasie trwania 0,5-24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mg Al/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Cząsteczki osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, przy wyższej dawce koagulantu (3,0 mg Al/dm3), równocześnie spowodowały stopniowy wzrost zdolności separacyjnych membrany i utworzenie tzw. membrany wtórnej. Przy czym charakteryzowała się ona mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
EN
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5-3.0 mg Al/dm3 and sedimentation where the scope of duration 0.5-24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mg Al/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after Edyta Łaskawiec, Mariusz Dudziak i Joanna 184 Wyczarska-Kokot coagulation with dose 3.0 mg Al/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
5
Content available remote Popłuczyny z obiegu wody basenowej - jakość i perspektywy oczyszczania
PL
Oceniono możliwości zastosowania procesu koagulacji objętościowej do oczyszczenia popłuczyn z instalacji uzdatniania wody w pływalni krytej. Efektywność wybranych koagulantów glinowych wstępnie zhydrolizowanych (zakres dawek: 0,5÷3,0 mgAI/dm3) oceniono w oparciu m.in. o zawartość zawiesin ogólnych oraz stężenia ogólnego węgla organicznego (OWO) w próbkach przed i po procesie koagulacji. Badane koagulanty wykazywały bardzo wysoką skuteczność w usuwaniu mętności (od 93% do 97%). Większość z badanych próbek popłuczyn po koagulacji charakteryzowała się zawartością zawiesin ogólnych, która pozwala na odprowadzenie ich do środowiska, (tj. poniżej 35 mg/dm3). Dodatkowo, zastosowanie koagulantu PAX 16 pozwoliło na obniżenie stężenia OWO w popłuczynach o ponad 60%. Za optymalną uznano dawkę PAX 16-0,5 mgAI/dm3. Pozostałe koagulanty wykazywały zróżnicowaną efektywność oczyszczania popłuczyn, która zależała od ich dawki. Zastosowanie procesu koagulacji popłuczyn w obiegach uzdatniania wody basenowej, daje możliwość ograniczenia ilości odprowadzanych ścieków do systemów kanalizacyjnych i ich bezpieczne odprowadzanie do środowiska. Niezbędna jest jednak indywidualna analiza jakości fizykochemicznej i objętości popłuczyn.
EN
The paper presents the possibilities of using a volumetric coagulation process to purification the backwashing water from a water treatment plant in an indoor swimming pool. The effectiveness of selected pre-hydrolyzed aluminium coagulants (in the dose of 0.5÷3.0 mgAI /dm3) was evaluated based on the amount of total suspended solids and the concentration of total organie carbon (TOC) in samples before and after the coagulation process. The coagulants tested showed high efficiency in removing turbidity (from 93 to 97%). Most of the tested samples of post-coagulum washings were characterized by the content of the total suspension, which would allow them to be discharged into the environment (less than 35 mg/dm3). In addition, the PAX 16 coagulant contributed to lowering the TOC concentration by more than 60% (throughout the range of doses used). The dose of PAX 16-0.5 mgAI/dm3) was considered as an optimal. Other coagulants showed varying effectiveness, highly dose dependent. The coagulation process may allow to limit the discharge of wastewater from the swimming pool facility and to discharge the washings into the environment in safety way. However, an individual analysis of physicochemical quality and volume of washings is indispensable.
6
Content available remote Ocena jakości popłuczyn z obiegów basenowych
PL
Eksploatacja obiektów basenowych związana jest z wysokimi kosztami. Racjonalna gospodarka wodno-ściekowa, uwzględniająca zagospodarowanie wody z popłuczyn, jest sposobem na obniżenie kosztów odprowadzania ścieków do kanalizacji. W pracy przedstawiono możliwości odprowadzenia popłuczyn z 5 różnych obiegów basenowych, do środowiska naturalnego. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono ich jakość. Wyniki badań porównano z dopuszczalnym stopniem zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800). Badania wykazały, że popłuczyny nie mogą być bezpośrednio odprowadzane do wód lub ziemi głównie ze względu na dużą zawartość zawiesin, chloru i wysokie wartości ChZT. Zastosowany, w warunkach laboratoryjnych, proces sedymentacji pozwolił na obniżenie ilości zawiesin i wskaźnika ChZT poniżej wartości dopuszczalnych. 2 godzinny czas sedymentacji wpłynął na zmniejszenie stężenia chloru. Przedstawiono również możliwości zagospodarowania wody nadosadowej oraz oszczędności wynikające z jej zagospodarowania.
EN
Exploitation of swimming pool facilities relates to high costs. Rational water and sewage management, considering the management of water from sewage, is a way to reduce the costs of sewage disposal to the sewerage system. The paper presents the possibilities of draining washings from 5 different swimming pools to the natural environment. Based on physical and chemical analyses of washings samples, their quality was determined. The results of the tests were compared with the permissible degree of pollution in wastewater discharged into water or soil (Journal of Laws 2014, item 1800). Studies have shown that washings cannot be directly discharged into water or soil mainly due to high content of suspended solids, chlorine content and high COD values. The sedimentation process, applied under laboratory conditions, has allowed the amount of suspensions and COD to be reduced below the limit values. 2-hour sedimentation time reduced chlorine concentration. The possibilities of management of the supernatant water and savings resulting from its management were also presented.
7
Content available remote The source of toxicity of backwash water from a swimming pool filter bed washings
EN
The necessity of reducing the operating costs of swimming pools leads to attempts to reuse of backwash water from washing swimming pool filter beds. Their use for watering plants, sprinkling tennis courts and play fields, draining to nearby watercourses or even returning to swimming pool installations is taken into consideration. Current researches proved the toxicity of these waste streams. The results of these studies raise doubts about the rightness of the attempts to introduce washings from pool filters directly into the environment. The aim of the presented work is to determine the source of toxicity of filter backwash water. The assessed in the work washings were characterized by high turbidity, high content of both suspended solids and organic compounds. A decrease in value of general impurity indicators after the filtration process of washings has been shown, suggesting that the main source of toxicity may be the suspension, including various anthropogenic organic micropollutants. Although this is just a research hypothesis. For this reason, comparative studies on the occurrence of toxic organic micropollutants in raw filter backwash water, supernatant water and filtrate collected after the filtration process were carried out.
EN
The main purpose of the research is to show the possibility of using washings after applying simple processes and devices. It is being considered whether they may be drained to watercourses, to the ground, used for watering plants, sprinkling tennis courts and playing fields, flushing toilets or recycled into pool systems. The research concept consisted of comparing the results of physico-chemical analysis of washings samples with the limit values for pollutants in wastewater discharged to water and ground. The research was carried out for 20 pool water treatment plants. It has been shown that the concentration of TSS (total suspended solids) and free chlorine in washings are the main parameters preventing their drainage to the natural environment. The processes of sedimentation or sedimentation assisted by coagulation allow to reduce the TSS concentration below the limit value and leaving the washings to stand for up to several hours or subjecting them to a few minutes of aeration decreases the concentration of free chlorine to an acceptable level. The obtained research results allow to assume that the management of washings in all tested swimming pools would be possible after applying a settler or a settling tank with a coagulant chamber and then a chamber for aeration.
EN
The paper presents usefulness of membrane processes (ultrafiltration (UF) and nanofiltration (NF)) for treatment of backwashing water of pool water system. The backwashings were taken from circulations located in two indoor facilities from pools of various functionalities. Moreover, the used samples had different quality in terms of physical and chemical parameters. The test used various membranes, both in respect of the polymer that they were made of and their separation capacity. Transport and separation properties of ultrafiltration (MW and V5) and nanofiltration (DK and HL) membranes were specified. Furthermore, backwashing water samples before and after membrane process treatment were subjected to Microtox® toxicity test. The conducted processes helped to reduce turbidity and specific absorbance at UV254nm 1m , both during ultrafiltration as well as nanofiltration.Much higher hydraulic performance was observed in ultrafiltration membranes. After each filtration cycle a Microtox® toxicity test was carried out which revealed reduced washings toxicity in relation to bacteria in all tested samples.
PL
W pracy określono przydatność procesów membranowych (ultrafiltracji UF i nanofiltracji NF) do oczyszczania popłuczyn filtracyjnych z instalacji wody basenowej. Popłuczyny zostały pobrane z obiegów zlokalizowanych w dwóch obiektach krytych, o różnym przeznaczeniu niecek. Próbki charakteryzowały się zróżnicowaną jakością, opisaną parametrami fizykochemicznymi. Badania prowadzono z wykorzystaniem różnych membrany, zarówno pod względem tworzącego ich polimeru, jak i zdolności separacyjnych. Wyznaczono właściwości transportowo-separacyjne membran UF (MWi V5) i NF (DK i HL). Dodatkowo próbki popłuczyn, przed i po procesie membranowym poddano przesiewowemu testowi toksycznościMicrotox®. Odnotowano obniżenie ilości substancji wpływających na mętność wody oraz związków organicznych wyrażonych wskaźnikiem absorbancji w UV254nm 1m , zarówno w procesach ultrafiltracji, jak i nanofiltracji. Znacznie wyższą wydajnością hydrauliczną odznaczały się membrany ultrafilracyjne. We wszystkich przeprowadzonych cyklach filtracyjnych stwierdzono obniżenie toksycznych właściwości popłuczyn w stosunku do bakterii Aliivibrio fischeri w teście Mirotox®.
PL
Przedmiotem opracowania jest określenie wpływu osadów potechnologicznych z uzdatniania wody na właściwości sedymentacyjne osadu czynnego. Przetestowane zostały popłuczyny z uzdatniania wód podziemnych oraz osad pokoagulacyjny z uzdatniania wód powierzchniowych. Badania przeprowadzono w warunkach laboratoryjnych na podstawie obserwacji opadalności osadu czynnego z dodatkiem zróżnicowanych objętości materiałów. Do oceny efektywności zastosowanych osadów potechnologicznych określono opadalność V30 i V60 (objętość osadu odpowiednio po 30 i 60 min. sedymentacji), indeks osadu czynnego, indeksu Donaldsona (indeksu gęstości osadu) oraz prędkość sedymentacji vs. Dodatkowo w celu weryfikacji poprawy opadalności z dodatkiem reagentów wprowadzono wskaźnik opadalności Wo będący ilorazem V30/V60. Badania wykazały przydatność zastosowania osadów potechnologicznych z uzdatniania wody do poprawy właściwości sedymentacyjnych osadu czynnego. Popłuczyny z uzdatniania wód podziemnych osiągnęły najwyższe efekty wspomagania osadu czynnego. Odnotowano maksymalnie 21,6% oraz 26,4% zmniejszenie indeksu osadu czynnego odpowiednio przy dawkowaniu osadu pokoagulacyjnego i popłuczyn. Maksymalny stopień poprawy prędkości sedymentacji osiągnięto przy najwyższych dawkach osadów technologicznych, odpowiednio 58,1% (OP) oraz 75,3% (PP). Mechanizm poprawy sedymentacji osadu czynnego z dodatkiem osadów potechnologicznych jest trudny do określenia, bowiem z jednej strony osad pokoagulacyjny i popłuczyny stanowią zawiesinę, w której obecne są cząstki mineralne o wielkości poniżej 200 µm będące obciążnikiem kłaczków osadu czynnego. Z drugiej jednak strony obecność żelaza w popłuczynach i glinu w osadach pokoagulacyjnych może wpływać na proces opadalności w analogiczny sposób jak koagulanty chemiczne PIX i PAX.
EN
The aim of the paper is the evaluation of post-technological sludge from Water Treatment Plant on improvement of sedimentation properties of activated sludge. The post-coagulation sludge from surface water treatment (OP) and backwash water from groundwater treatment (PP) were used in this study. The studies were performed in the laboratory scale by observing the settleability of activated sludge with the addition of different volume of post-technological sludge. The activated sludge quality used in this study was characterised by a strong sludge bulking and a wide range of sludge volume index. For the evaluation of the efficiency of tested materials in activated sludge the settleability after 30 V30 and V60 minutes, the sludge volume index SVI, the Donaldson index SDI (Sludge Density Index) and value settling velocity vs were determined. Additionally, in order to verify of activated sludge settleability with the addition of post-technological sludge was appointed a sludge settling ratio (Wo) which is a quotient of V30 and V60. Studies showed the usefulness of the application of post-technological sludge from water treatment to improve of sedimentation properties of the activated sludge. Settling tests showed different efficiencies in the activated sludge settleability, depending on the type and amount of post-technological sludge. At a dosage of post-coagulation sludge and backwash water was observed up to 21.6% and 26.4% reduction of sludge volume index. The maximum level of improvement of settling velocity at the highest doses of post-technological sludge amounted to 58.1% (OP) and 75.3% (PP). Better effects of improvement of activated sludge sedimentation were obtained using backwash water than post-coagulation sludge. The mechanism of improvement of sedimentation properties of the activated sludge containing post-technological sludge is difficult to determine. On the one hand the post-coagulation sludge and backwash water are a suspension, wherein the mineral particles are present, which is a weight of activated sludge flocs. The incorporation of particles into flocs of activated sludge increases its relative density On the other hand, the presence of iron ions in backwash water and aluminum ions in post-coagulation sludge may affect the sedimentation activated sludge in the same manner as the chemical coagulant. The backwash water or post-coagulation sludge may be a new effective reagent in activated sludge technology.
PL
W pracy przedstawiono wyniki badań, na podstawie których określono możliwość odprowadzenia popłuczyn, powstałych w wyniku płukania złóż filtracyjnych w systemie oczyszczania wody basenowej, do pobliskiej rzeki. Na podstawie analiz fizyczno-chemicznych próbek popłuczyn określono stopień ich zanieczyszczenia. Wyniki badań porównano z zaleceniami dotyczącymi dopuszczalnego stopnia zanieczyszczeń w ściekach odprowadzanych do wód lub ziemi (DzU 2014, poz. 1800) i wymaganiami pozwolenia wodnoprawnego wydanymi dla analizowanego obiektu basenowego. Analiza wyników badań popłuczyn surowych (niepoddanych obróbce) wykazała, że bezpośrednie ich odprowadzenie do rzeki jest niemożliwe przede wszystkim ze względu na duże stężenie chloru wolnego oraz ilość zawiesin ogólnych. Analiza wyników badań popłuczyn poddanych procesowi sedymentacji lub koagulacji objętościowej w warunkach laboratoryjnych pozwoliła zaprojektować system odprowadzenia wody nadosadowej do rzeki. Warunkiem „zrzutu” wody nadosadowej do rzeki będzie konieczność zastosowania zbiornika buforowego, osadnika lub systemu wspomagającego sedymentację zawiesin w popłuczynach np. poprzez zastosowanie koagulacji objętościowej, a następnie odprowadzanie zagęszczonych ścieków do kanalizacji sanitarnej.
EN
The paper presents the results of studies on determining of the possibility of discharge washings, as a result of rinse filter beds in the swimming pool water treatment system, to the river. Based on the physical and chemical analysis of washings samples the degree of their contamination was determined. The results were compared with the recommended acceptable level of pollutants in wastewater discharged to water or soil (OJ 2014, item 1800) and with the requirements of the water permit issued for the analyzed swimming pool. The obtained results for raw washings (untreated) showed that direct discharge of washings into the near located river is impossible, especially due to the high concentration of free chlorine and the amount of total suspended solids (TSS). Analysis of the results of washings subjected to the process of sedimentation or coagulation in the laboratory helped design the system supernatant water drain into the river. The condition of such management would be to use a buffer tank, settling tank or supporting system to sedimentation of suspended solids, e.g. the use of coagulation and then the draining of concentrated sewage into the sanitary sewage system.
EN
Results of research on physico-chemical and bacteriological quality of effluents from backwashing of filter beds were presented for water treatment system of a selected swimming pool (waterpark). The aim of these studies was to evaluate potential to discharge the backwash water from rapid filter beds to a river or to drain them into the ground. Based on the physico-chemical and microbiological analysis of backwash water samples, degree of their contamination was determined with regard to the current quality requirements for wastewater discharged into surface water or soil as well as the requirements under the Water Law Act that defined water quality to be discharged from the analyzed pool. It was demonstrated that direct routing of the eluate from backwashing into the river or soil was impossible due to a high amount of total suspended solids and chlorine content. The concurrent efficacy testing of sedimentation and alum coagulation of backwash water performed under laboratory conditions demonstrated that the obtained supernatant water complied with the requirements and might be discharged into the river or drained into the ground.
PL
Przedstawiono wyniki badań jakości fizyczno-chemicznej i bakteriologicznej popłuczyn powstających w wyniku płukania złóż filtracyjnych w układzie oczyszczania wody w wybranym obiekcie basenowym (park wodny). Celem badań było określenie możliwości odprowadzania popłuczyn z filtrów pospiesznych do rzeki lub ich rozsączania w gruncie. Na podstawie wyników analiz fizyczno-chemicznych i mikrobiologicznych próbek popłuczyn określono stopień ich zanieczyszczenia w odniesieniu do wymagań dotyczących jakości ścieków odprowadzanych do wód lub do ziemi obowiązujących w Polsce oraz wymagań zawartych w pozwoleniu wodnoprawnym, które określa wymaganą jakość wód odprowadzanych z analizowanego obiektu basenowego. Wykazano, że bezpośrednie odprowadzanie popłuczyn z płukania filtrów do rzeki lub ziemi jest niemożliwe, ze względu na dużą ilość zawiesin ogólnych oraz zawartość chloru w popłuczynach. Jednocześnie przeprowadzone w warunkach laboratoryjnych badania skuteczności procesów sedymentacji i koagulacji objętościowej popłuczyn koagulantem glinowym wykazały, że uzyskane w ten sposób wody nadosadowe spełniają warunki odprowadzania ich do rzeki lub rozsączania w gruncie.
EN
This study discusses the results of the preliminary tests use an integrated process coagulationsedimentationnanofiltration for the purification washings from swimming pool water treatment circulation. Studies included the effect of the terms and conditions of the preparatory process (coagulation where range of doses of coagulant 1.5–3.0 mgAl/dm3 and sedimentation where the scope of duration 0.5–24 h) on the transport and separating properties nanofiltration membranes. Comparatively, the process of nanofiltration of raw washings has been performed. DK GE Osmonics membrane was used as a nanofiltration membrane. A higher value of volumetric permeate flux was observed during the nanofiltration process for washings after coagulation process with dose 1.5 mgAl/dm3. There has also been significant improvement in transport capacity of the membrane with increased sedimentation time (to 24 hours). The presence of sediment molecules, which contributed to the reduction of the process efficiency during filtration of washings after coagulation with dose 3.0 mgAl/dm3, at the same time they caused a gradual increase in membrane separation capacity. A secondary membrane having a lower porosity than the primary membrane has been produced. The use of the integrated system has improved the transport conditions of the nanofiltration membranes, reduction of residual aluminium concentration, as well as significant improvements in other physicochemical parameters (inter alia reduction the amount of suspended solids and ultraviolet absorbance UV254).
PL
W pracy przedstawiono wyniki badań dotyczących zastosowania zintegrowanego procesu koagulacji–sedymentacji–nanofiltracji do oczyszczania popłuczyn z obiegu uzdatniania wody basenowej. Badania obejmowały ocenę wpływu warunków prowadzenia procesów wstępnych, tj. koagulacji (zakres dawek koagulantu 1,5–3,0 mgAl/dm3) oraz sedymentacji (czas trwania 0,5–24 h) na własności transportowo-separacyjne membran nanofiltracyjnych. Porównawczo przeprowadzono proces nanofiltracji surowych popłuczyn. Obserwowano wyższą wartość objętościowego strumienia permeatu w trakcie procesu nanofiltracji dla popłuczyn po koagulacji (dawka koagulantu 1,5 mgAl/dm3). Stwierdzono znaczącą poprawę zdolności transportowych membrany wraz z wydłużeniem czasu sedymentacji (do 24 h). Obecność cząsteczek osadów, które przyczyniały się do obniżenia wydajności filtracji popłuczyn po koagulacji, w której zastosowano wyższą dawkę koagulantu (3,0 mgAl/dm3), równocześnie spowodowała stopniowy wzrost zdolności separacyjnych membrany – utworzyła się tzw. membrana wtórna charakteryzująca się mniejszą porowatością niż membrana pierwotna. W badanym przypadku zastosowanie układu zintegrowanego pozwoliło na poprawę warunków transportowych membran nanofiltracyjnych, zmniejszenie stężenia glinu pozostałego oraz znaczną poprawę pozostałych parametrów fizykochemicznych (m.in. zmniejszenie ilości zawiesin ogólnych i obniżenie absorbancji w nadfiolecie UV254).
PL
Odpowiadając na pytanie: nie, nie muszą. Co więcej – optymalizacja w gospodarce popłuczynowej kopalni może stanowić potencjał poprawy wyników ekonomicznych.
PL
W artykule przedstawione zostały wyniki pomiarów rozkładów wielkości cząstek zawiesin zawartych w popłuczynach pochodzących ze stacji uzdatniania wód podziemnych w Golędzinowie. Próbki popłuczyn pobierano w trzech seriach badawczych w trakcie płukania filtrów do odżelaziania i odmanganiania w okresie od 20 sierpnia 2013 roku do 6 marca 2014 roku. Do oznaczenia składu granulometrycznego zawiesin użyto granulometr laserowy Mastersizer 2000. Badania wykazały, że w trakcie płukania filtrów rozkład wielkości cząstek zawiesin był zmienny. W zawiesinie w ujęciu objętościowym dominowały cząstki o wielkościach 1-100 μm, a w ujęciu ilościowym 0,1-1 μm. Dodatkowo dla filtra odmanganiającego we wszystkich fazach płukania uzyskiwano wyższe wartości wielkości cząstek niż w przypadku filtra odżelaziającego.
EN
The study presents the results of measurement of particle size distribution in suspensions contained in spent filter backwash water obtained from the Groundwater Treatment Plant in Golędzinów. Spent filter backwash water samples were collected in three test series during the backwashing of iron and manganese removal filters, during the period from the 20th of August, 2013 to the 6th of March, 2014. Granulometric composition was determined by means of Mastersizer 2000 laser granulometer. The tests have proven that during the backwashing of filters the particle size distribution in suspensions was subject to changes. In terms of volume, particles of a size of 1-100 μm were dominant in the suspension, while in quantitative terms – particles of a size of 0.1-1 μm. Additionally, for the manganese removal filter higher particle size values were obtained in all stages of backwashing than for the iron removal filter.
EN
In Poland, water supply for villages and small towns is provided mainly from groundwater resources. In spite of good physicochemical and bacteriological properties for groundwater, in most cases it is required to remove iron and manganese, which influences the applied treatment technologies. The processes of potable water treatment result in the emergence of certain by-products, i.e. technological wastewater (mainly spent filter backwash water) and sediments that contain the pollutants removed from water. The study presents the results of the Authors’ tests of particle size and quantity distribution in spent filter backwash water from the groundwater treatment plant in Kąty Wrocławskie. The paper also contains an analysis of the changeability of iron and manganese content and turbidity in different phases of filter backwashing (initial backwashing, air backwashing, second backwashing). The research consisted of four series of tests conducted during the period from July 2013 to May 2014. Spent filter backwash water samples were collected during backwashing of two filters. Test results have shown that the quality of spent filter backwash water changed on subsequent stages of backwashing. Suspension particles of a size ranging from 10÷20 μm accounted for the highest volume percentage share in the analysed samples of spent filter backwash water from both filters, while the quantitative distribution of particles of the given diameters was heterogeneous and it depended on the stage of filter backwashing.
PL
W Polsce w celu zaopatrzenia w wodę wsi i małych miasteczek ujmowane są przede wszystkim zasoby wód podziemnych. Pomimo dobrych właściwości fizyczno-chemicznych i bakteriologicznych wykazywanych przez wody podziemne większość z nich wymaga odżelaziania i odmanganiania, co ma wpływ na technologie ich uzdatniania. Podczas procesów uzdatniania wody przeznaczonej do spożycia przez ludzi powstają produkty uboczne, tj. ścieki technologiczne (głównie popłuczyny) oraz osady, w których zawarte są zanieczyszczenia usuwane z wody. W pracy przedstawiono wyniki własnych badań rozkładów wielkości i ilości cząstek zawiesin w popłuczynach ze stacji uzdatniania wód podziemnych w Kątach Wrocławskich. W artykule przeanalizowano również zmienność zawartości żelaza, manganu oraz mętności w różnych fazach płukania filtrów (płukanie wstępne wodą, płukanie powietrzem, płukanie właściwe wodą). Badania obejmowały cztery serie badawcze w okresie od lipca 2013 roku do maja 2014 roku. Próbki popłuczyn były pobierane podczas płukania dwóch filtrów. Wyniki badań wykazały, że jakość popłuczyn ulegała zmianie w kolejnych etapach płukania. Największy udział procentowy cząstek w badanych próbkach popłuczyn z płukania obydwu filtrów w ujęciu objętościowym stanowiły cząstki zawiesin o wielkościach z zakresu 10÷20 μm. Natomiast rozkład ilościowy cząstek o danych średnicach był niejednorodny i zależał od etapu płukania filtrów.
EN
Swimming pools are very expensive, in terms of operation, sports facilities. Therefore, investors and managers of these facilities are looking for methods of reducing the costs of their use. One of the proposed methods is the managing of washings previously discharged to the sanitary sewage system. The assessment of possibilities for reuse of washings from swimming pool filtration system is based on the limits of basic indicators of pollutants in wastewater discharged to water and soil (temperature, pH, TSS, BOD5, COD, TN, TP, free chlorine). The conducted research of washings quality from 26 tested swimming pools have shown that washings quality is dependent on the operating conditions of the pool circuit, including the filter cycle duration and types of filter bed. A direct discharge to water or soil may be impossible due to excessive amounts of total suspended solids (above 35 mg/dm3) and free chlorine concentration (above 0.2 mg Cl2/dm3). However, the quality of supernatant water of washings subjected to sedimentation in the laboratory shows that the washings are suitable for reuse. The installation of settling tanks in swimming pool facilities could relieve the sewage systems and allow for the discharge of supernatant water to surface waters or for the irrigation of green areas in an environmentally friendly way.
EN
The paper presents the physicochemical analysis and toxicological assessment of backwashing samples taken after the process of washing filter beds in a raw condition after the process of their aeration and dechlorination. The backwash water under investigation originated from circulation systems existing in two indoor swimming pool facilities. The backwash water, as used at the preliminary and the main stages, was characterized by different physicochemical properties. For toxicological assessment, the Mictorox® bioluminescence inhibition test, the Chaoborus sp. insect larva survival test and the phyto test using Lemna minor fine cilium were involved. The investigation presented in the paper included a preliminary phase focusing on the ecotoxic characterization of backwash water subjected to aeration and dechlorination processes. In turn, at the main stage, the effect of aeration duration on the quality of backwash water in terms of its physicochemical parameters was analyzed. The results of the preliminary stage investigation indicate that backwash water, both in a raw condition and after 30 minutes’ aeration, could not be discharged directly to the environment due to the threat to living organisms caused by its high toxicity. Whereas, using 160 minutes’ aeration duration contributed to a significant improvement in the quality of the backwash water and elimination of its toxic properties with respect to the indicator organisms used. The chemical dechlorination process brought about varying effects. In the case of the Microtox® test, a stimulation of bacterial bioluminescence was noted, but, at the same time, the death of individual insect larva specimens was observed. In spite of the high biomass increase in the Lemna minor test, a gradual discolouration of fronds under the influence of backwash water was observed. Because of the presence of numerous compounds being disinfection by-products, as well as coagulant residues in backwash water deriving from swimming pool systems, it is necessary to seek further solutions that will allow them to be recycled, which will result in a reduction of water consumption and effluent discharges.
PL
W pracy przedstawiono analizę fizykochemiczną oraz ocenę toksykologiczną próbek popłuczyn pobranych po procesie płukania złóż filtracyjnych w stanie surowym po procesie napowietrzania oraz dechloracji. Badane popłuczyny pochodziły z obiegów zlokalizowanych w dwóch obiektach basenowych krytych. Do oceny toksykologicznej włączono test inhibicji bioluminescencji Mictorox®, przeżywalności larw owadów Chaoborus sp. oraz fitotest z wykorzystaniem rzęsy drobnej Lemna minor. Badania obejmowały fazę wstępną, skupiającą się na charakterystyce ekotoksykologicznej popłuczyn poddanych procesom dechloracji oraz napowietrzania. W etapie zasadniczym badań analizowano dodatkowo wpływ czasu napowietrzania na jakość popłuczyn pod względem parametrów fizykochemicznych. Wyniki wstępnego etapu badań sygnalizuj ą, że popłuczyny zarówno w stanie surowym, jak i po 30-minutowym napowietrzaniu nie mogły zostać bezpośrednio odprowadzone do środowiska ze względu na zagrożenie dla organizmów żywych, spowodowane ich wysoką toksycznością. Natomiast zastosowane wydłużenie czasu napowietrzania (160 min) przyczyni ło się do znaczącej poprawy jakości popłuczyn i pozbawienia ich właściwości toksycznych w stosunku do wykorzystanych organizmów wskaźnikowych. Zróżnicowane efekty przyniósł zabieg chemicznej dechloracji. W przypadku testu Microtox® odnotowano stymulację bioluminescencji bakterii, równocześnie zaobserwowano śmierć pojedynczych osobników larw owadów. Pomimo wysokiego przyrostu biomasy w teście z Lemna minor, zaobserwowano stopniowe odbarwienie frondów pod wpływem użytych popłuczyn. Niezbędne jest poszukiwanie dalszych rozwiązań umożliwiających ich recykling, co zapewni ograniczenie zużycia wody oraz odprowadzania ścieków.
PL
W pracy przedstawiono możliwość wykorzystania membranowego procesu ultrafiltracji do oczyszczania popłuczyn z instalacji basenowych. Badania obejmowały proces jednostkowy ultrafiltracji oraz zintegrowany układ napowietrzanie-ultrafiltracja, który pozwolił na częściowe usunięcie zanieczyszczeń występujących w nadawie. Porównano membrany o zróżnicowanym materiale polimerowym oraz różnej wartości granicznej masy molowej cut-off. Określono wpływ zastosowanego procesu wstępnego na zdolności transportowo-separacyjne membran o różnych własnościach fizyczno-chemicznych. Uzyskano wysoką wydajność hydrauliczną we wszystkich prowadzonych filtracjach (w zakresie od 1,23·10-5 do 1,40·10-7 m³/m²·s). W zakresie usuwania mętności badane układy charakteryzowały się współczynnikiem usunięcia przekraczającym 90%. Odnotowano znaczące usunięcie grupy zanieczyszczeń opisanych przez wskaźnik ogólny, tj. absorbancję w nadfiolecie UV254. Przeprowadzone badania wykazały możliwość wykorzystania ultrafiltracji do odzysku wody basenowej z popłuczyn poprocesowych.
EN
The paper presents the possibility of using the membrane ultrafiltration process for the treatment of washings from pool water systems. The tests included a unit ultrafiltration process and airing-ultrafiltration integrated system which partly removed contamination from the feed material. Membranes of various polymere materials and molar mass cut-off were compared. This helped to determine the influence of the used initial process on transport and separation abilities of the membranes of different physical and chemical features. High hydraulic performance was obtained in all performed filtration actions (1.23·10-5 ÷ 1.40·10-7 m³/m²·s). In respect of fighting turbidity, all tested systems had a removal rate of more than 90%. It was also noted that a significant amount of contamination described by the general indicator, which is specific UV254 absorbance, was removed. The tests proved that ultrafiltration can be used for recovery pool water from post-process washings.
PL
Baseny to bardzo drogie pod względem eksploatacji obiekty sportowe, dlatego też osoby zarządzające tymi obiektami szukają sposobów na obniżenie kosztów ich użytkowania. Jednym z nich jest zagospodarowanie popłuczyn dotychczas odprowadzanych do kanalizacji sanitarnej. Oceny możliwości zagospodarowania popłuczyn odprowadzanych z filtracyjnych instalacji basenowych dokonano na podstawie dopuszczalnych wartości podstawowych wskaźników zanieczyszczeń w ściekach odprowadzanych do wód i ziemi (pH temperatura, zawiesiny ogólne, ChZT, BZT5, Pog, Nog, chlor wolny). Badania jakości popłuczyn z 26 basenów wykazały, że ich jakość jest zależna od warunków eksploatacji danego obiegu basenowego, m.in. długości cyklu filtracyjnego i rodzaju złoża. Parametrami uniemożliwiającymi bezpośrednie zagospodarowanie popłuczyn były zbyt duża zawartość zawiesin ogólnych (≥ 35 mg/dm3) oraz stężenie chloru wolnego (≥ 0,2 mg Cl2/dm3). Jakość wód nadosadowych powstałych w wyniku sedymentacji popłuczyn wskazuje na ich przydatność do zagospodarowania. Zastosowanie w obiektach basenowych odstojników popłuczyn umożliwiłoby odciążenie systemów kanalizacji i odpływ wód nadosadowych do wód powierzchniowych lub ich wykorzystanie do nawadniania terenów zielonych w sposób bezpieczny dla środowiska.
EN
Swimming pools are very expensive in terms of exploitation sports facilities, therefore managers of these facilities are looking for methods of reducing the costs of their use. One of the proposed method is the managing of washings previously discharged to the sanitary sewage system. The assessment of possibilities of washings reusing from swimming pool filtration system is based on the limits of basic indicators of pollutants in wastewater discharged to water and soil (temperature, pH, TSS, BOD5, COD, TN, TP, free chlorine). The conducted research of washings quality from 26 tested swimming pools have shown that washings quality is dependent on the operating conditions of the circuit pool, including the filter cycle duration and types of filter bed. The parameters which prevents direct management washings were too high content of total suspended solids (≥ 35 mg/dm3) and the concentration of free chlorine (≥ 0.2 mg Cl2/dm3). Quality washings subjected to sedimentation indicates its usefulness for rational management. The application in swimming pools settling tanks allows discharge sewage systems and drainage supernatants to surface waters or using to irrigation green areas in an environmentally safe way.