Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 21

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pompa grzejna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
The conditions of efficient use of heat pumps in air conditioning systems are considered in order to ensure the established temperature and relative humidity of air in premises with the removal of excess moisture in the warm or hot periods of the year. For this purpose, a thermodynamic analysis of heat pump air conditioning schemes with exhaust air recirculation through a condenser and through a heat pump evaporator has been carried out. To determine the potential capabilities of such schemes to maintain comfortable conditions in the production room, a numerical analysis of their operating parameters, depending on the temperature and relative humidity of external atmospheric air, was performed. It has been shown that recirculation of exhaust air through the heat pump evaporator allows to maintain the given conditions in the room in a wider range of parameters of external atmospheric air. In addition, it has been shown that such a scheme requires less specific energy consumption for the operation of heat pump, which means that it is more efficient.
2
Content available Obiegi termodynamiczne. Druga zasada termodynamiki
PL
Wstęp i cele: W pracy opisano obieg termodynamiczny silnika cieplnego, Carnota, chłodziarki i pompy grzejnej, Ponadto przedstawiono sprawność termiczną obiegu silnika oraz sprawność energetyczną obiegu chłodniczego i obiegu grzejnego. Omówiono różne sformułowania drugiej zasady termodynamiki. Celem pracy jest przedstawienie graficzne obiegów termodynamicznych silnika, chłodziarki i pompy grzejnej oraz analiza teoretyczna sprawność energetycznej omawianych obiegów termodynamicznych. Materiał i metody: Materiał stanowią źródła z literatury z zakresu termodynamiki. W pracy zastosowano metodę analizy teoretycznej. Wyniki: Rezultatem pracy jest przedstawienie graficzne i omówienie obiegów termodynamicznych silnika cieplnego, chłodziarki i pompy grzejnej. Ponadto w pracy przestawiono analizę teoretyczną sprawności termicznej obiegu silnika, sprawności energetycznej obiegu chłodniczego i grzejnego. Wniosek: Aby zrealizować obieg silnika nie wystarczy tylko dostarczać ciepło, lecz konieczne jest też odprowadzanie ciepła. Obieg chłodniczy lub obieg grzejny jest lewobieżny i może składać się z równych przemian termodynamicznych. Sprawność termiczna silnika może być zwiększona poprzez podniesienie temperatury ciepła doprowadzanego i obniżenie temperatury ciepła odprowadzanego.
EN
Introduction and aim: The paper describes the thermodynamic cycle of the heat engine, Carnot, refrigeration and transient pump. In addition, the thermal efficiency of the motor cycle and the energy efficiency of the refrigeration cycle and heating circuit have been presented. Different definitions of the second law of thermodynamics have been discussed. The aim of this paper is graphic representation of thermodynamic cycles of the engine, refrigerator and heating pump as well as theoretical analysis of energy efficiency of the discussed thermodynamic cycles. Material and methods: Material covers some sources based on the literature in the field of thermodynamics. The method of theoretical analysis has been shown in the paper. Results: The result of the work is a graphic representation and discussion of the thermodynamic cycles of the heat engine, the refrigerator and the heating pump. In addition, the work presents the thermodynamic analysis of the thermal efficiency of the motor cycle, the energy efficiency of the cooling and heating circuits. Conclusion: In order to realize the motor cycle, it will not only provide heat, but also heat removal. The refrigeration circuit or heating circuit is left-handed and may consist of even thermodynamic transformations. The thermal efficiency of the motor can be increased by raising the temperature of the heat supplied and reducing the temperature of the heat dissipated.
PL
Przedmiotem pracy jest analiza nieustalonych procesów zachodzących w układzie grzewczym zasilanym sprężarkową parową pompą grzejną, dla której dolnymźródłem ciepła jest górotwór. W górotworze zainstalowany jest pionowy U-rurowy wymiennik ciepła. Zapotrzebowanie na ciepło dla ogrzewanego obiektu jest zmienne podczas sezonu grzewczego i zależne od parametrów otoczenia, pompa grzejna funkcjonuje zaś w cykliczny sposób, dostarczając wymaganą ilość ciepła do przestrzeni ogrzewanej. Jest ona wspomagana także okresowo przez dodatkowe, szczytowe źródło ciepła. W związku z tym, w sezonie grzewczym ciepło jest pobierane z gruntu także w cykliczny sposób, co wpływa na jego stan termiczny. Opracowany model matematyczny umożliwia przeprowadzanie analiz termodynamicznych obejmujących długie okresy funkcjonowania układu – kolejne sezony grzewcze, z uwzględnieniem regeneracji termicznej gruntu w okresach wiosenno–letnich, podczas których układ nie funkcjonuje. W pracy przedstawiono przykładowe obliczenia dla dwóch kolejnych sezonów grzewczych. Otrzymane rezultaty w postaci sezonowej zmienności m.in. takich parametrów jak temperatury w charakterystycznych punktach układu, wydajność cieplna pompy grzejnej, strumienie ciepła pobieranego z gruntu, czy też sezonowe zużycie energii pozwalają porównać pracę układu w pierwszym i drugim sezonie grzewczym oraz stopień regeneracji termicznej gruntu podczas przerwy w działaniu układu.
EN
This paper is dedicated to modeling of processes taking place in the heating system with the vapour compressor heat pump. Ground is a low heat source for this heat pump. Vertical, U-tube heat exchanger is located in the ground and heat is transferred from the ground to the heat pump by an intermediate medium. The system, equipped additionally by peak heat source, provides heated building with heat. Processes taking place in this system are dependent on time. Heat demand for the heated object and characteristic parameters, among others, evaporation and condensation temperatures, temperatures of the heating water and intermediate medium, heat fluxes: taken from the ground and transferred to the heated space are varied during the heating season. Thermal state of the ground around the pipes of the heat exchanger is also varied. Thermal analysis of the system was carried out for long operation time, i.e. two consecutive heating seasons, taking into account operation break during spring and summer. Calculation were performed using in-house numerical code, which used commercial program ANSYS FLUENT for calculating the temperature distribution in the ground and in the walls of the heated object.
PL
Dla typowych wartości efektywności energetycznej pomp grzejnych (pomp ciepła) oraz przyjętych wartości sprawności systemu grzewczego, wyznaczono stosunek nakładu energii pierwotnej do nakładu energii użytkowej, czyli EP/EU, charakteryzujący wpływ zastosowania pompy grzejnej w takim systemie. Aby uwypuklić wpływ cech charakteryzujących pracę pompy grzejnej na wskazany iloraz, przeanalizowano zastosowanie w takim samym systemie grzewczym innych źródeł ciepła, w dodatku zasilanych różnorodnym paliwem.
EN
For typical values of the energy efficiency of heating pumps (heat pumps) and adopted values of the efficiency of heating system, the ratio of primary energy input to the usable energy input (PE/UE) has been determined to characterise the impact of heating pump application in such a system. To highlight the impact of characteristics of heating pump on the indicated quotient, the use of other heat sources in the same system has been analysed. Additionally, various kinds of fuel have been used.
PL
Przedmiotem pracy jest analiza nieustalonych procesów cieplnych zachodzących w obszarze gruntowego wymiennika ciepła współpracującego ze sprężarkową parową pompą grzejną. Zaprezentowano dwuwymiarowe modele numeryczne gruntowego poziomego oraz pionowego U-rurowego wymiennika ciepła, uwzględniające m.in. charakterystykę układu przepływowego wymiennika oraz charakterystykę pompy obiegowej czynnika pośredniczącego. Głównymi wynikami obliczeń są strumienie ciepła pobieranego z gruntu, przyrost temperatury czynnika pośredniczącego oraz rozkład temperatury w gruncie wokół rur wymiennika. Zaprezentowano przykładowe rezultaty analizy dla obu typów gruntowych wymienników ciepła.
EN
Thermal unsteady processes in the ground heat exchanger system of heat pump are analysed in the paper. The two-dimensional numerical model of the horizontal and U-tube vertical heat exchanger is presented in the paper. The model takes into consideration characteristic of intermediate medium circulating pump and characteristic of flow system of this medium. The model allows the analysis of the hydraulic resistances influence on ground heat exchanger functioning. Heat flux taken from ground, the increase in the intermediate medium temperature and temperature field in the ground adjacent to the heat exchanger pipes are the main results of calculations. Exemplary results for both ground heat exchangers are also presented and analysed.
PL
Przedstawiono zasady i szczegóły klasyfikacji różnych postaci energii. Wskazano na istotną różnicę między pojęciem zasobu energii odnawialnej a źródłem tej energii. Na tym tle wykazano, dlaczego pompa grzejna nie może być zaliczana do odnawialnych źródeł energii, chociaż zwykle pobiera energię z zasobów odnawialnych. Wreszcie przedstawiono możliwości wykorzystania geoenergii, w tym i za pośrednictwem pomp grzejnych.
EN
The principles and some classification details of various forms of energy are presented. A substantial difference between the resource of the renewable energy and the energy source has been indicated. It is pointed out why a heating pump cannot be classified as a renewable energy source, even though normally it draws the energy from the renewable resources. Finally, the possibilities of the geoenergy usage, including the application of heating pumps, are shown.
PL
Praca dotyczy modelowania numerycznego przepływu ciepła wgruncie w otoczeniu rur poziomego gruntowego wymiennika ciepła pompy grzejnej zainstalowanego na terenie polderów, do których jest zrzucana woda o podwyższonej temperaturze z oczyszczalni ścieków. Omówiono metodę obliczeń pól temperatury w rozpatrywanym układzie, przedstawiono rezultaty tych obliczeń, jak również obliczeń jednostkowego strumienia ciepła pobieranego od gruntu przez rury wymiennika. Przeanalizowano wpływ infiltracji gruntu przez wodę ściekową na strumień ciepła przejmowanego w wymienniku.
EN
Numerical technique and obtained results of numerical calculations for underground horizontal heat exchanger of heat pump are presented in the paper. The analysed ground heat exchanger is located in the region of waste dumping from a sewage-treatment plant. Determination of the temperature distributions in the domain pertinent to the exchanger pipes, as well as heat flux densities transferred from considered ground was the main aim of the calculations. Influence of the water flow in ground on the heat flux transferred in the exchanger is also analysed.
PL
Przedstawiono układ technologiczny nowoczesnego źródła ciepła dla obiektu sportowo-rekreacyjnego w miejscowości nadmorskiej. Obok kotłów olejowych zastosowano, jako podstawowe źródło ciepła, zespół sprężarkowych pomp grzejnych o znacznej mocy. Pracę pomp grzejnych oparto na pionowych sondach gruntowych, czerpiących energię geotermiczną.
EN
A technological system of a modern heat source provided for a sport and recreation centre in a seaside resort is presented. An assembly of heating compressor pumps of considerable power has been applied with oil boilers as a basic heat source. The pump operation is possible due to the vertical ground probes fed by the geothermal power.
PL
W pracy przedstawiono rezultaty obliczeń numerycznych pola temperatury w otoczeniu rur gruntowego wymiennika ciepła pompy grzejnej oraz jednostkowego strumienia ciepła pobieranego od gruntu. Przeanalizowano wpływ ruchu wody gruntowej na strumień ciepła przejmowanego od gruntu w przykładowym wymienniku z rurami poziomymi.
EN
Results of numerical calculations for underground heat exchanger of heat pump are presented in the paper. Determination of the temperature distributions in the domain neighbouring pipes, as well as heat flux densities transferred from the ground, were the main aim of the calculations. Influence of the moisture flow on the heat flux transferred from the ground in the exemplary horizontal exchanger is also analysed.
PL
W pracy przedstawiono rezultaty analizy procesów cieplnych zachodzących w obszarze wokół gruntowego pionowego wymiennika ciepła pompy grzejnej. Rezultatem obliczeń jest nieustalone pole temperatury w powtarzalnym rozpatrywanym fragmencie górotworu oraz strumień ciepła przejmowanego od gruntu podczas sezonu grzewczego.
EN
In the paper there are given the results of analysis of heat transfer processes in the region of heat pump vertical ground heat exchanger. Unsteady temperature field in the analysed repetitive part of the ground and heat fluxes being transferred from the ground during all heating season are the results of calculations.
PL
W pracy przedstawiono możliwości wykorzystania energii promieniowania słonecznego akumulowanego w gruncie w cyklach rocznych. Energia ta, pochłaniana głównie w okresie wiosenno-letnim, jest następnie wykorzystywana jako źródło ciepła dla układów z pompami grzejnymi (pompami ciepła). Ciepło pobierane jest od górotworu w poziomym lub pionowym gruntowym wymienniku ciepła, przy czym nośnikiem "zimna" jest odpowiedni niezamarzający roztwór, np. wodny roztwór glikolu etylenowego. Czynnik ten następnie przekazuje ciepło w parowaczu medium roboczemu pompy grzejnej. Celem pracy jest głównie zaprezentowanie przykładowych rezultatów złożonych obliczeń numerycznych, których wynikiem jest pole temperatury w gruncie oraz strumienie pobieranego ciepła.
EN
In the paper there are presented some possibilities of utilization of solar energy accumulated in the ground in annual cycles. Solar energy absorbed mainly during spring-summer time is then used as a heat source for systems with heat pumps. Heat is transferred from the ground by use of horizontal or vertical heat exchangers and the suitable non-freezing intermediate medium having a form, e.g., a water solution of ethylene glycol is used. This medium transfers then heat in evaporator to the working medium of heat pump unit. The aim of the paper there is the presentation of exemplary results of complex thermal calculations for the vertical ground heat exchanger. The results of these calculations have a form of temperature distributions in the ground as well as the heat fluxes taken from the ground.
PL
Omówiono znaczenie stosowania w energetyce i ciepłownictwie skojarzonej gospodarki cieplno-elektrycznej. Wskazano, że umożliwia ona stosowanie sprężarkowych pomp grzejnych do efektywnego zagospodarowania lokalnych niskotemperaturowych zasobów energii odpadowej i ze źródeł odnawialnych. Przedstawiono pojęcie generacji rozproszonej oraz wskazano typowe przykłady technologii stosowanych w źródłach rozproszonych. Podano główne przyczyny zainteresowania nimi i rozwoju tych technologii. Scharakteryzowano, ostatnio zrealizowane w krajowym ciepłownictwie, wybrane przykłady zastosowań skojarzonych źródeł rozproszonych, zasilanych różnorodnym paliwem gazowym.
PL
W pracy przedstawiono rezultaty wstępnych obliczeń numerycznych zrealizowanych dla pionowego, gruntowego wymiennika ciepła pompy grzejnej. Celem obliczeń było wyznaczenie pola temperatury w powtarzalnym fragmencie gruntu w sąsiedztwie rury oraz jednostkowych strumieni ciepła pobieranych od gruntu przez pojedynczą pionową rurę wymiennika, przy uwzględnieniu zjawiska zmiany fazy wilgoci w gruncie.
EN
In the paper the results of numerical calculations for vertical underground heat exchanger of heat pump are presented. Determination of temperature distributions in the repetitive fragment of the domain neighbouring pipe, as well as heat flux densities transferred from the ground to the single yertical pipe, were the aim of the calculations. The phase change of moisture in the ground was taken into account.
PL
Przedstawiono wyniki analizy termodynamicznej procesów cieplnych zachodzących w obszarze gruntowego wymiennika ciepła pompy grzejnej. Otrzymane rezultaty mają postać nieustalonego pola temperatury oraz strumieni ciepła przejmowanych przez czynnik pośredniczący znajdujący się wewnątrz rur rozpatrywanego wymiennika. Rury te mogą przy tym być zainstalowane w układzie poziomym lub pionowym.
EN
In the paper there are given the results of thermal analysis of heat transfer processes in the region of heat pump ground heat exchanger. The results have a form of unsteady temperature field and heat fluxes being transferred to the intermediate agent flowing inside the pipes of the exchanger. The pipes of ground heat exchanger may be installed in horizontal or vertical system.
15
Content available remote Koncepcja ciepłowni zagospodarowującej energię zawartą w wodzie kopalnianej
PL
Przedstawiono koncepcję modernizacji kotłowni zasilającej w ciepło kopalnię i/lub przyległe osiedle mieszkaniowe, przeprowadzanej pod kątem zagospodarowania dołowych wód kopalnianych do celów ciepłowniczych. W koncepcji zaproponowano zastosowanie jako podstawowego źródła ciepła zespołu: zasilany gazem spalinowy blok elektryczno-ciepłowniczy-sprężarkowa pompa grzejna lub absorpcyjna pompa grzejna-wysokotemperaturowy kocioł wodny. Moc grzejna tego zespołu znajdując się w jego dolnym zakresie regulacyjnym powinna całkowicie zapewnić pokrycie zapotrzebowania na ciepło poza sezonem grzewczym. W sezonie grzewczym podstawowe źródło jest niewystarczające i wymaga uzupełnienia działaniem innych źródeł ciepła, jak np. kotły obciążenia szczytowego. Dla pracy podstawowego źródła ciepła podano podstawowe wskaźniki charakteryzujące jego efektywność energetyczną.
EN
In this paper the concept of mine's heating plant modernisation is presented. The heat supplies housing esatate or mine by heating plane. The modernisation is prepared by taking into accunt the management of mine's waters for heating purposes. In the concept as a basic of heating source the combustion electric-heating block, compressor or absorption heat pump and high temperature boiler are proposed. Thermal power of this system should cover heat requirement after heating season. But in heating season basic heating source is insufficient and there is need to utilization other heating sources as e.g. boilers. For work of basic heat source main factors, which characterise thermal efficiency, are given.
PL
Do zdefiniowanych poprzednio cząstkowych sprawności termodynamicznych określających wpływ nieodwracalności poszczególnych procesów cząstkowych na efektywność energetyczną pompy grzejnej parowej sprężarkowej dodano sprawność instalacji zewnętrznej. skorygowano pozostałe sprawności.
EN
The previosly defined partial thermodynamic efficiencies have been supplemented with the efficiency of the extermal installation. The remaining partial efficiencies have been corrected.
PL
Dokonano oceny efektywności energetycznych stosowania sprężarkowych pomp grzejnych zasilanych energią elektryczną z krajowego systemu elektroenergetycznego oraz ze spalinowego bloku ciepłowniczo-elektrycznego, a także przeprowadzono wzajemne porównanie tych dwu sposobów zasilania. Wspomniane pompy grzejne zastosowano do zagospodarowania do celów grzewczych niskotemperaturowej energii odpadowej lub ze źródeł odnawialnych. Jako kryterium efektywności energetycznej wykorzystano skumulowane zużycie energii chemicznej paliwa przypadającego na wytworzenie jednostki ciepła w układzie utworzonym przez elektrociepłownię parową lub gazową wraz z pompą grzejną. Przeprowadzona analiza energetyczna wykazała stosowne uwarunkowania, a także wyższość napędu spalinowego nad zasilaniem pomp grzejnych z systemu elektrycznego.
PL
Przedstawiono analizę energetyczną dotyczącą możliwości zagospodarowania energii wody termalnej do celów grzewczych za pomocą sprężarkowych pomp grzejnych w ciepłowni komunalnej. W ciepłowni tej, obok wodnego kotła zasilanego gazem ziemnym, znajduje się spalinowy blok elektryczno-ciepłowniczy, z którego ciepło zasila układ wody sieciowej, zaś energia elektryczna służy do napędu pompy grzejnej wykorzystującej energię wody termalnej. Dla wybranych dwu parametrow charakteryzujących ciepłownię, podano podstawowe proporcje uzyskiwanego ciepla z różnych urządzeń cieplnych ciepłowni, a także uzyskiwane w nich przyrosty temperatury wody sieciowej.
PL
Zdefiniowano cząstkowe sprawności termodynamiczne określające wpływ nieodwracalności poszczególnych procesów cząstkowych na efektywność energetyczną pompy grzejnej parowej sprężarkowej.
EN
Partial thermodynamic efficiencies have been defined which determine the influence of the particular irreversible processes of the coefficient of performance of the considered heat pump.
PL
Przedstawiono zasadę działania typowej sprężarkowej pompy ciepła służącej do ogrzewania. Omówiono problem efektywności zastępownia urządzeń wytwórczych ciepła pompami grzejnymi. Następnie przeprowadzono analizę ekonomiczną zastosowania sprężarkowej pompy ciepła na tle innych systemów ogrzewania w typowym budynku jednorodzinnym.
EN
The paper presents the idea of implementing heat pump unit for heating purposes. The problem of replacing the conventional heat sources by the heat pump was also disccused. Then economic analysis of using heat pump installation for supplying heat for a traditional single family house was carried out.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.