Content available remote Results of numerical modeling of three-pipe heat exchanger for livestock premises
EN
Developed a three-pipe heat recovery system containing three coaxially installed pipes (inner, middle and outer), a condensate drain pipe that passes through the outer pipe and is located at the bottom of the middle pipe, an exhaust shaft that passes through the outer pipe, supply and discharge air filter, which is additionally equipped with an ultraviolet lamp. As a result of numerical modeling of the heat recovery device, the distribution of the temperature and vector velocity fields is established.
PL
Opracował trójrurowy system odzysku ciepła składający się z trzech współosiowo zainstalowanych rur (wewnętrznej, środkowej i zewnętrznej), rury spustowej kondensatu, która przechodzi przez rurę zewnętrzną i znajduje się na dole rury środkowej, szybu wylotowego, który przechodzi przez rurę zewnętrzną rurowy, filtr powietrza nawiewanego i wylotowego, który dodatkowo wyposażony jest w lampę ultrafioletową. W wyniku modelowania numerycznego urządzenia do odzysku ciepła ustala się rozkład pól temperatury i prędkości wektorowych.
PL
Obecność drobnoustrojów chorobotwórczych w budynkach inwentarskich może stanowić istotny problem dla hodowców/rolników, dlatego dbając o dobrostan zwierząt hodowlanych/gospodarskich powinni oni regularnie przeprowadzać dezynfekcję pomieszczeń z zastosowaniem środków i metod umożliwiających osiągniecie zadowalających efektów. Praca miała na celu analizę porównawczą właściwości biobójczych preparatów zalecanych do dezynfekcji w pomieszczeniach inwentarskich na podstawie hamowania w warunkach in vitro wzrostu bakterii: Staphylococcus aureus ATCC29213, Escherichia coli ATCC25922, Pseudomonas aeruginosa ATCC27853, Salmonella enterica subsp. enterica serowar Typhimurium ATCC14028, Enterobacter cloacae, Bacillus cereus, B. pseudomycoides i B. thuringiensis. Zbadano dziesięć preparatów pochodzących od różnych producentów, o różnym składzie, rekomendowanych jako dezynfekujące. Analizy wykonano metodą dyfuzyjną. Nie wszystkie przebadane preparaty wykazywały zadowalające działanie przeciwbakteryjne – jedynie trzy skutecznie hamowały rozwój wszystkich bakterii testowych w zalecanych dawkach, dlatego producenci powinni rzetelniej opisywać działanie oferowanych produktów i nie narażać hodowców/ rolników na nieskuteczną dezynfekcję pomieszczeń. Najlepsze właściwości przeciwbakteryjne wykazały dwie grupy preparatów: zawierające aktywne formy srebra – nanocząstki (nr 1) oraz czwartorzędowe związki amoniowe, glutaral i chlorki w różnych proporcjach (2 i 3). Bakterie Gramujemne były mniej wrażliwe od Gram-dodatnich na działanie badanych preparatów, bez względu na zawarte w nich substancje aktywne, co może stanowić istotny problem w przypadku salmonelloz, zatruć wywołanych przez Escherichia coli i zakażeń Pseudomons aeruginosa oraz innych chorób, których przyczyną są pałeczki Gram-ujemne.
EN
The presence of pathogens in livestock buildings can be a major problem for farmers, because taking care of the welfare of the animals, they should carry out regular disinfection of the premises using preparations and methods to achieve satisfactory results. The work was aimed at comparative analysis of the biocidal properties of the preparations recommended for the disinfection in livestock facilities on the basis of in vitro inhibition of growth of bacteria: Staphylococcus aureus ATCC29213, Escherichia coli ATCC25922, Pseudomonas aeruginosa ATCC27853, Salmonella enterica subsp. enterica ser. Typhimurium ATCC14028, Enterobacter cloacae, Bacillus cereus, B. pseudomycoides and B. thuringiensis. Studies were performed using five different in composition products from different manufacturers using diffusion method. Not all tested preparations had satisfactory antibacterial activity – only three effectively inhibited the growth of all tested bacteria at the recommended doses, so manufacturers should accurately describe the effects of the offered products and do not expose farmers to carry out ineffective disinfection of the buildings. Best antimicrobial properties revealed the two groups of tested preparations: containing the active forms of silver – nanosilver (no. 1) and quaternary ammonium compounds, glutaral and chloride in various proportions (no. 2 and no. 6). Gram-negative bacteria were less sensitive than the Gram-positive on tested chemicals regardless of the active agents which can be a significant problem in the case of salmonellosis, Escherichia coli intoxications and Pseudomons aeruginosa infections and other diseases that are caused by Gram-negative bacteria.
PL
Badania kształtowania się temperatury odczuwalnej przeprowadzono w samoogrzewalnej, bezokiennej tuczarni trzody chlewnej, osłoniętej od północnej strony pomieszczeniem do obsługi zwierząt, a od południowej nieogrzewaną paszarnią, charakteryzującą się stosunkowo dużymi oknami z pojedynczymi szybami ze zwykłego szkła oraz betonową posadzką, poddawaną bezpośrednio operacji słonecznej. W oddziałach tuczu, usytuowanych - jeden od wschodu, a drugi od zachodu, ustalono po trzy stanowiska pomiarowe, tj. w ich północnej, środkowej i południowej części. W każdym miesiącu rocznych badań stwierdzono najkorzystniejsze kształtowanie się temperatury odczuwalnej na stanowiskach pomiarowych w południowej części tuczarni. Uzyskane wyniki potwierdziły przepływ do pomieszczeń dla zwierząt ciepła pozyskiwanego w paszarni z promieniowania słonecznego.
EN
The research of the perceptible temperature forming was conducted in the self heating, without windows fattening house, shielded from northern side by the room for animals' services and from southern side by non-heating food store, characterizing by comparatively large windows with single glasses from usual glass and by concrete floor, exposed directly to the sunny operation. In the fattening sections, which are situated - one from east, and second from west, there were established three measuring positions, in northern, central and southern parts. Almost in every month of yearly research, there were confirmed the most advantageous forming of the perceptible temperature on measuring positions in the southern part of the fattening house. The achieved results confirmed the flow of warmth gained from sunny radiation in the food store to rooms for animals.