Mining plants are among the industrial plants where there is a very rapid change in the configuration of the electricity network (progress of works, decommissioning of pits), and the mechanisation and automation of works involves the use of advanced power electronic systems. This entails differences in operation and the occurrence of disruptions in mine networks. The main threats to the correct operation of the equipment are changes in the shape of the voltage waveforms, the rms value of the voltage and the frequency of the waveforms feeding the equipment. An analysis of failures in the power grid of the Sobieski mine has shown that problems with maintaining adequate power quality cause uncontrolled interruptions of the production process, lasting many hours, resulting in economic losses. The problem is undoubtedly the lack of legislation that regulates this issue holistically. Neither the regulation on detailed conditions for the operation of the electricity system nor the regulations related to mining facilities are explicit in this respect.
PL
Artykuł dotyczy wpływu złej jakości dostawy energii elektrycznej na funkcjonowanie zakładów górniczych. Omówiono kryteria oceny jakości dostawy energii elektrycznej, źródła zaburzeń w sieciach elektroenergetycznych zakładów górniczych oraz wpływ złej jakości energii elektrycznej na bezpieczeństwo pracy załóg górniczych. Przedstawiono wyniki pomiarów oraz analizy odpowiednich wskaźników w wybranych kopalniach.
PL
W pracy przedstawiono metodykę i wyniki pomiarów stanów nieustalonych w zasilaczu bezprzerwowym (UPS) typu on - line. Do rejestracji zdarzeń po stronie zasilania i na wyjściu UPS wykorzystano dwa przyrządy do pomiaru jakości energii elektrycznej zsynchronizowane czasowo. Rejestratory kompresują uzyskane dane pomiarowe, co może wprowadzać dodatkowe błędy pomiaru wielkości mierzonych – napięć i prądów. Dodatkowe rejestracje oscyloskopem wielokanałowym potwierdziły poprawność danych uzyskiwanych w celu określenia reakcji zasilacza na zaburzenia występujące na wejściu i wyjściu urządzenia. W pracy analizowano wyniki pomiarów impedancji pętli zwarciowej zmierzone przyrządem wymuszającym poziomy prądu zwarciowego na linii zasilającej odbiorniki energii elektrycznej we wszystkich stanach pracy zasilacza, a następnie porównywano je z wynikami obliczeń przeprowadzonych na uzyskanych przebiegach prądu i napięcia.
EN
The paper presents the methodology and the results of transient measurement in on-line Uninterruptable Power Supply (UPS). There were two power quality measurement instruments (synchronised with time) used for registering the events in UPS input and output. The recorders compress the obtained measurement data, which may introduce additional measurement errors of measured values, i.e. voltage and current. Additional registrations with a multi-channel oscilloscope confirmed the correctness of the obtained data in order to determine the reaction of the UPS to the disturbances occurring in UPS input and output. The work analysed the results of loop impedance, measured by a meter that forces short-circuit current in the line supplying electric load, in all states of the UPS, and then they were compared with the results of calculations carried out on the obtained current and voltage waveforms. The measurement of fault loop impedance in UPS output line should be performed in active static switch (bypass mode), because UPS will operate in this mode after switching from inverter operation due to high current forcing during a short circuit in the UPS output. Measurement of fault loop impedance in UPS output circuits, when it is in AC-DC-AC double conversion mode, may result with loop impedance overstating by meters, which in turn limits recognition of the tested installation as safe from the protection against electric shock by automatic power off point of view. The values of calculated loop impedance at forced high current, i.e. 160 A in the UPS output, when it is respectively in the manual bypass and static switch mode, are 4% and 2.5% lower than the ones presented by meter after measure by forcing high current. Differences in impedance of the static switch and manual bypass UPS mode can be the basis for the estimation of the thyristor impedance. Estimation of direct measurement results with 14.6 m, and according to the calculation of recorded transients it is about 16.1 m.
3
Content available remote Pomiary porównawcze wyższych harmonicznych napięcia w sieci przesyłowej 400 kV
PL
W artykule przedstawiono analizę wyników pomiarów porównawczych wyższych harmonicznych napięcia wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
EN
In the paper the comparative analysis of voltage harmonics measurements performed in the transmission network of 400 kV is presented. The voltage were measured using three measuring instruments: resistive voltage divider, inductive voltage transformer and capacitive voltage transformer. Measurement errors were estimated for transformers with reference to the harmonic values obtained with the use of the voltage divider.
EN
The paper deals with the analysis of voltage harmonics measurements performed in the 400 kV transmission network. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.
PL
W artykule przedstawiono analizę wyników pomiarów wyższych harmonicznych napięcia, wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Wyniki pomiarów z dzielnika rezystancyjnego przyjęto jako referencyjne, odnosząc do nich wyniki pomiarów uzyskane przy wykorzystaniu przekładników. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
PL
Przedstawiono analizę wyników pomiarów wyższych harmonicznych napięcia wykonanych w sieci przesyłowej 400 kV. Sygnały pomiarowe napięć uzyskano z trzech przetworników pomiarowych: rezystancyjnego dzielnika napięcia, napięciowego przekładnika indukcyjnego oraz napięciowego przekładnika pojemnościowego. Wyniki pomiarów z dzielnika rezystancyjnego przyjęto jako referencyjne odnosząc do nich wyniki pomiarów uzyskane przy wykorzystaniu przekładników. Dokonano oszacowania błędów pomiarowych wyższych harmonicznych napięcia powodowanych przez przekładniki.
EN
The paper deals with the analysis of voltage harmonics measurements performed in the transmission network of 400 kV. The voltage was measured by means of three transducers: resistive voltage divider, inductive measuring transformer and capacitive voltage measuring transformer. Instrument errors were estimated for measuring transformers with reference to the harmonic values obtained from the voltage divider.