1
Content available remote Validity of the FAR validation using Site Reference Method
EN
Electromagnetic radiation from devices is measured in fully anechoic chambers which are validated by site attenuation measurement. Fully anechoic room was validated using Reference Site Method according to CISPR 16-1-4. Author investigate influence of the validation conditions on result of this procedure. Frequency step, antennas positioning were examined and reference measurement was analyzed.
PL
Emisja promieniowana pochodząca od urządzeń może być mierzona w komorach bezodbiciowych które są walidowane poprzez pomiar tłumienia stanowiska. Podstawą niniejszej pracy jest walidacja komory całkowicie bezodbiciowej wykorzystując metodę stanowiska odniesienia zgodnie z normą CISPR 16-1-4. Autor bada wpływ różnych warunków walidacji na wynik procedury. Sprawdzono wpływ kroku częstotliwości, precyzji ustawiania anten oraz przeanalizowano procedurę wykonywania pomiaru referencyjnego.
PL
W pracy rozważono wpływ sztywności porowatej matrycy na własności tłumiące kompozytu z cieczą magnetoreologiczną na bazie oleju półsyntetycznego oraz cząstek żelaza karbonylkowego o średnicy 10 μm. Badania przeprowadzono dla dwóch różnych grubości kompozytu i zmiennej wartości natężenia pola magnetycznego z przedziału od H = 0 kA/m do H = 200 kA/m. Rejestrowano przebiegi czasowe siły F(t), przemieszczenia x(t), prędkości przemieszczenia v(t), co umożliwiło także uzyskiwanie pętli histerezy w układach wpółrzędnych F-v oraz F-x. Analiza pętli histerezy pozwoliła na ocenę funkcjonowania kompozytu. Wykazano możliwość optymalizacji matrycy ze względu na aplikacje kompozytu w układach tłumiących.
EN
In the work the influence of porous matrix stiffness on damping properties of the composite with Magnetorheological Fluid was investigated. The composite was created by saturating porous matrix with one type of Magnetorheological Fluid based on semi-synthetic oil and carbonyl iron particles of diametres equal to 10 μm. The testing was done for two values of matrix thickness and different values of magnetic field stregth in a range of H = 0 kA/m to H = 200 kA/m. Time courses of force F(t), displacement x(t), and velocitywere recorded that made possible to get hysteresis loops in co-ordinate systems F-v and F-x. The analysis of hysteresis loops enabled to evaluate functioning of the composite. Possibility of matrix optimization with respect to the application of the comopsite in damping system was presented.
EN
The paper deals with two methods of measuring mechanical systems' damping based on Fast Fourier Transform (FFT). The method based on evaluation of damping from vibration decay in time domain is compared to the method based on evaluation of damping from the measured frequency response functions. The comparison of measurement results is carried out and advantages and disadvantages of both methods in estimation of damping for both lightly and heavily damped mechanical systems are evaluated.
EN
Traditional methods of damping measurements involved the use of sinusoidal signals for excitation of the test specimen. With the coming of dual channel real-time analyzers, wide-band random excitation can be conveniently used to excite and measure the response of the test specimens simultaneously, whereby considerable time savings can be achieved. The precision of the complex modulus and damping measurements using non-resonant method is evaluated.
PL
Tradycyjne metody pomiaru tłumienia posługują się dla wymuszenia sygnałem o przebiegu sinusowym. Wraz z pojawieniem się dwukanałowego analizatora w czasie rzeczywistym zaczęto powszechnie używać szerokozakresowego przypadkowego wymuszenia w parze z równoczesnym pomiarem reakcji próbki, co z kolei umożliwia znaczne zaoszczędzenie czasu. Dokładność pomiaru modułu całościowego i tłumienia metodą nierezonancyjną rozpatrywana jest w poniższym artykule.