Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pomiar mocy biernej
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This article presents a selection analysis of the parameters used for a half-band filter in a digital Hilbert transformer. The parameters were determined for the transformer’s use in measuring Budeanu reactive power. This solution allowed to check the operation of the filter by comparing the results obtained with the filter with the results of Budeanu reactive power obtained in the frequency domain. Fifty half-band filters were designed and tested. As a result of the analysis the best filter was chosen. For this half-band filter the obtained values of the relative error of the reactive power measurement were less than or equal to 0.01% for different types of load parameters, signals and sampling frequencies.
PL
W artykule przedstawiono analizę doboru parametrów filtra half-band, stosowanego w transformatorze Hilberta. Parametry te określono dla transformatora zastosowanego do pomiaru mocy biernej według Budeanu. Rozwiązanie takie pozwoliło sprawdzić działanie filtra porównując otrzymane z jego użyciem wyniki mocy z wynikami otrzymanymi w dziedzinie częstotliwości ze wzoru Budeanu. Do testów zaprojektowano pięćdziesiąt filtrów Hilberta. Z nich wybrano filtr o najlepszych parametrach, dla których błąd pomiaru mocy biernej był mniejszy lub równy 0.01% dla różnych sygnałów wejściowych, typów odbiornika i częstotliwości próbkowania.
PL
W artykule przedstawiono krótką biografię urodzonego w pierwszej połowie XIX wieku w Wielkopolsce Hermanna Arona. Jego nazwisko kojarzone jest przede wszystkim ze znanym układem do pomiaru mocy czynnej i biernej w obwodach trójfazowych, realizowanym za pomocą dwóch watomierzy. Godna uwagi jest nie tylko jego kariera naukowa, ale również działalność przemysłowa, w której z niewielkiego warsztatu wyrosło w krótkim czasie uznane międzynarodowe przedsiębiorstwo Aron-Werke. To w tej fabryce powstawały pierwsze opatentowane przez Arona liczniki energii elektrycznej.
EN
A short biography of Hermann Aron, born in Polish Province Wielkopolska in the first half of the 19th century, has been presented in the paper. His surname is associated first of all with the well-known system used for measuring both active and reactive powers in three-phase circuits by means of two wattmeters. Not only his scientific career is notable but also his industrial activity. Aron-Werke, a company of international renown, came into existence from a small workshop in a short period of time. The first electricity meters, patented by Aron, came into being precisely in this factory.
PL
W artykule zamieszczono opis oryginalnej metody pomiaru mocy biernej wg definicji Budeanu przy odkształconych przebiegach napięcia i prądu. Przedstawiono również propozycję rozwiązania pomiaru mocy biernej sieci energetycznej wg zaleceń IEEE wykorzystującego wspomnianą metodę. Przedstawione propozycje poparto wynikami symulacji.
EN
The article contains description of original measurement method of reactive power when the voltage and current are non-sinusoidal. The proposal for measurement algorithm of measurement reactive power in electrical network according to recommendations IEEE using mentioned method is presented. The proposal is supported by simulation results.
PL
Zbyt duży i niekontrolowany pobór mocy biernej wpływa również, poza innymi czynnikami, na jakość energii elektrycznej. Stąd, między innymi, wynika konieczność jej pomiaru z dokładnością technicznie bądź ekonomicznie uzasadnioną. W przeciwnym przypadku mogą wystąpić trudności w otrzymaniu wymaganego współczynnika mocy. Na poprawny pomiar mocy biernej wpływ ma rónież asymetria obciążenia. W referacie przedstawiono wykorzystanie techniki planowania eksperymentu, która w powiązaniu symulacją komputerową (LabVIEW) pozwala badać wpływ asymetrii obciążenia na dokładność pomiaru mocy biernej w układach trójfazowych przez stworzenie modelu matematycznego opisującego błędy przetworników mocy biernej.
EN
The use of planning experiment technique and computer simulation for testing of asymmetry of the load influence on the reactive power measurement accuracy in 3-phase systems is presented. The way of working out of the mathematical model describing errors of the reactive power converters is presented with virtual technique and the LabVIEW platform.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.