Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  polystyrene foam
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
One of the wastes generated by PT Beton Elemenindo Perkasa is polystyrene foam waste. Processing of this type of waste is still done with open burning so it has an impact on health and the environmental quality degradation. One of the polystyrene foam waste processing technologies is by constructing a combustion furnace equipped with carbon filter. Activated carbon is one of the air filter media that can absorb harmful gases from the combustion process. The purpose of this research is to identify the effectiveness of carbon monoxide (CO) concentration reduction on active carbon contact system using variation of particle size. This research is a kind of an experimental study involving post test with control design. The number of samples was calculated based on the number of treatments and the number of repetitions in the study. This research used 2 kinds of treatment, including 20 mesh and 30 mesh in 9 repetitions. Independent T-Test statistical analysis showed a significant difference (p-value = 0.001) between the variation of particle size of activated carbon and the CO parameters with the average of the most effective reduction percentage on particle-sized active carbon of 30 mesh was 77.95%.
PL
Izolacje termiczne budynków wykonane z płyt styropianowych cechują się niskimi kosztami, stabilnością kształtu i odpornością na zawilgocenie, ale utrudniają odprowadzenie wody technologicznej z konstrukcji budynku. Sytuację może poprawić zastosowanie styropianu perforowanego, jednak jego podaż jest ograniczona z uwagi na brak technologii umożliwiającej masową produkcję. W IMBiGS – we współpracy z ZPB "Jerzy Maciejewski" – podjęto się realizacji projektu badawczego w zakresie technologii oraz urządzeń do masowej produkcji styropianu perforowanego. W opracowanej technologii perforacja następuje w wyniku wytapiania otworów przez rozgrzane wgłębniki, a pakiet płyt jest perforowany w dwóch przejściach roboczych. Urządzenie uzyskuje maksymalną wydajność 20 m 3/h dzięki możliwości perforowania całych, zafoliowanych pakietów płyt.
EN
Thermal insulation of buildings with the use of polystyrene boards is characterized by low costs, stability in shape and resistance to moisture but it hampers a drainage of process water from the buildings structure. The situation may be improved by applying a perforated polystyrene foam but its supply is limited due to the lack of mass production technology. IMBiGS – in cooperation with ZPB "Jerzy Maciejewski" – conducted a research within the field of technologies and machines for mass production of perforated polystyrene foam. In the new technology perforation results from smelting holes through heated indenters. A set of boards is perforated in two operating transitions. The machine reaches maximum performance 20 m 3/h due to the possibility of perforating complete and foiled sets of boards.
EN
Due to toxicity of volatile organic compounds (VOC), assessment of their emission from polymer dry construction materials is of importance for the quality of the indoor environment. Accordingly, in this work we studied emissions of styrene from polystyrene foam (PSf) and of cyclopentane from polyurethane foam (PURf). Both foams are common insulation materials. The partition (K) and diffusion (D) coefficients of these compounds in respective foams were determined at temperature between 23-90 °C. The partition coefficients of foam-ambient gas system (KM-A) derived from the determined adsorption and desorption rate constants (kads, kdes) using the close-to-equilibrium theory and computer simulation, resulting in comparable values. The diffusion coefficients, by contrast, were obtained using three models based on sorption (DS), permeation (DP) and computer simulation (DC). In the first model, the foam is seen as a continuous phase, in the second model - as consisting of two phases where the VOC concentration is arithmetically averaged, while the third one assumes the inhomogeneous VOC distribution. Based on the same experimental data, three sets of diffusion coefficients were obtained (DS, DP, DC), disparate in values, these disparities originating from the assumptions made in each model. The computer-simulation at relatively low migrant concentrations in the foam (styrene-PSf system), and the permeation model at high migrant concentrations (cyclopentane-PURf system) generated the diffusion coefficients comparable with results presented in the literature.
PL
Ze względu na toksyczność lotnych związków organicznych (volatile organic compounds - VOC), oznaczanie emisji tych związków z polimerowych, suchych materiałów budowlanych ma ogromne znaczenie z punktu widzenia jakości środowiska we wnętrzu domów. W opisanej poniżej pracy zbadano kinetykę emisji styrenu z pianki styropianowej (PSf) oraz cyklopentanu z pianki poliuretanowej (PURf, rys. 1 i 2). Obydwie pianki są powszechnie stosowanymi materiałami izolacyjnymi. Oznaczono współczynniki podziału (K) i dyfuzji (D) badanych związków w piankach w zakresie temperatury 23-90 °C. Współczynniki podziału w układzie pianka-otaczający gaz (KM-A) obliczono z wyznaczonych wartości stałych szybkości sorpcji i desorpcji (kads, kdes) związków na piankach, z zastosowaniem kinetyki reakcji I rzędu w pobliżu stanu równowagi i symulacji komputerowej. Obydwie metody obliczeniowe dały porównywalne wyniki (tabele 1-3). Natomiast do obliczenia współczynników dyfuzji związków w piankach, posłużono się trzema modelami opartymi na: sorpcji związków w piankach (DS), ich permeacji przez pianki (DP) bądź na symulacji komputerowej (DC). W modelu sorpcyjnym zakłada się, że pianka jest fazą ciągłą, podczas gdy w modelu permeacyjnym - składa się z dwóch faz, w których stężenie VOC jest uśrednione; model symulacyjny zakłada niehomogeniczny rozkład stężenia VOC. Wychodząc z tego samego zestawu danych pomiarowych otrzymano trzy zestawy wspomnianych współczynników dyfuzji (DP, DS, DC) różniących się wartościami (tabela 4). Różnice te są wynikiem założeń poczynionych w każdym modelu. Porównywalne z danymi literaturowymi (tabela 5) wartości współczynników dyfuzji w obszarze względnie małych stężeń migranta w piance (układ styren-PSf) uzyskano metodą symulacji komputerowej, a w przypadku większych stężeń (cyklopentan-PURf) - zgodnie z modelem permeacyjnym.
PL
Przedstawiono metodę określania współczynnika ekstynkcji [kappa] oraz współczynnika albedo [omega] pianki polistyrenowej ekstrudowanej stosowanej do izolacji cieplnej w budownictwie, podczas pomiarów przewodności cieplnej w aparacie płytowym z ochronną płytą cieplną.
EN
A method of determining the extinction coefficient [kappa] and albedo coefficient [omega] of extruded polystyrene foam, applied in building engineering as a thermal insulator, is presented. The determination is made during the measurement of thermal conductivity of the polystyrene foam in a Guarded Hot Plate Apparatus.
PL
W części 1 i 2 przedstawiono metodę określania współczynnika ekstynkcji K pianek z tworzyw sztucznych stosowanych do izolacji cieplnej w budownictwie, podczas pomiarów przewodności cieplnej tych pianek w aparacie płytowym z ochronną płytą cieplną oraz jej implementację dla pianki sztywnej polistyrenowej ekstrudowanej (XPS).
EN
A method of determining the extinction coefficient and albedo coefficient of extruded polystyrene foam, applied in building engineering as a thermal insulator, is presented. The determination is made during the measurement of thermal conductivity of the polystyrene foam in a Guarded Hot Plate Apparatus.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.