Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 46

Liczba wyników na stronie
first rewind previous Strona / 3 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  polychlorinated biphenyls
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 3 next fast forward last
EN
The Southwest Nigeria has witnessed tremendous increase in the output of municipal wastes in the recent years. Non availability of government policy on solid wastes management or its lack of effectiveness where it exists makes unabated open burning the predominant means of municipal solid waste disposal in the region. Open burning of municipal wastes being a major source of anthropogenic air emissions was investigated for atmospheric loading of some hazardous organic pollutants using the emission inventory method. The specific pollutants considered in this study were volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polychlorinated dibenzo –p- dioxin (PCDDs) and polychlorinated dibenzo furan (PCDF). The estimated release of VOCs, PAHs, PCBs, PCDD and PCDF from open burning of municipal wastes in the region over the 5-year period investigated were 64000 tonnes, 988 tonnes, 43 tonnes, 0.56 tonnes and 0.2 tonnes respectively. Given the serious human health implications associated with these hazardous organic pollutants, the study suggested conversion of wastes to energy as a possible solution since the region also faces energy challenges.
EN
An efficient method of burning polychlorinated biphenyls (PCBs) is often used to remove the environmental burden of PCBs. However, combustion produces toxic dioxins and furans (PCDD/F), so residents are increasingly rejecting this method. The heat treatment (HT) method does not burn PCBs but evaporates it from sediments. Even in this process, PCDD/Fs are formed to a lesser extent, which are destroyed by radiation processing (RP) following the HT. At the same time, the RP method degrades PCB congeners down to biphenyls, which decompose easily in the environment. A block assembly of a complex synergistic combination of equipment for methods of thermal (HT) and radiation (RP) destruction of PCBs in sediments is proposed. The efficacy of this complex was preliminarily determined at a level of 70-fold reduction in PCB concentration in sediments. To achieve a higher reduction factor in the concentration of PCBs, possible procedures for optimizing the settings of individual devices of this complex are presented.
EN
The aim of this study was to investigate the impact of industrial waste landfill on the release of polychlorinated biphenyls (PCBs) on the environment with reference to water flow directions. 10 study plots were designated around the landfill site. Soil samples were taken from different soil layers. Plants: Solidago canadensis (leaves, stem), Quercus L. (leaves), and Poaceae were tested on PCBs contents. Groundwater samples were taken from piezometers. PCBs in the samples were determined by gas chromatography with an electron capture detector (GC/ECD). The highest accumulation of PCBs congeners was observed in the topsoil layers and decreased with the sampling depth. The dominant PCBs congeners in soil were PCB 28 and PCB 138, in plants PCB 28 and PCB 52. The most significant PCBs accumulation in the topsoil layer occurred in the research area on which the largest amount of waste was deposited and was equal to 14.2 ng/g. The largest sum of determined PCBs congeners was found in Solidago canadensis leaves – 3.26 ng/g and Quercus L. leaves – 3.32 ng/g. PCB 28 and PCB 52 were capable of translocation from soil to plants. It was found that the water flow direction did not affect PCB content in soils.
EN
The article presents issues related to biodegradation of polychlorinated biphenyls in soil by inoculation with a biopreparation IN-3 developed on the basis of microorganisms capable of metabolizing PCB. Biodegradation tests were carried out using the ex-situ technological pile method on a specially constructed test stand. As part of the research, physical and chemical analyzes of the initial soil were performed, with particular regard to the content of nutrients (nitrogen and phosphorus), PCB chromatographic analyzes and toxicological analyzes. Before inoculating soil with biopreparation IN-3, the parameters of the process were established (temperature = 17–25°C, humidity = 20–25%, pH = 7.5–7.8, content of nutrients: C:N:P = 100:10:1), which were monitored during bioremediation. During soil treatment, the content of identified PCB congeners was monitored. The assessment of biodegradation efficiency of polychlorinated biphenyls in soil was complemented by toxicological monitoring, which was carried out using live organisms representing all trophic levels: producers (PhytotoxkitTM test), consumers (Ostracodtoxkit FTM test) and reducers agents (Microtox®SPT test). Also, the presence of mutagenic factors were tested with the Ames mutagenicity test. As a result of the six-month biodegradation process of soil contaminated with aged transformer oil, upon inoculation with biopreparation IN-3, a reduction in the content of polychlorinated biphenyls from 13 153.9 µg/kg d.m. down to 1650.4 µg/kg d.m. (87.5%) was archieved. The obtained chromatographic analysis results showed that the efficiency of the PCB biodegradation depended on the number of chlorine atoms in the biphenyl ring (with the increase in the number of chlorine atoms in the PCB molecule the degree of biodegradation decreased) and the structure of the molecule (PCB congeners having 2 or more chlorine atoms in the biphenyl ring ortho positions were more difficult to biodegrade than non-ortho or mono-ortho, while polychlorinated biphenyls, in which chlorine atoms occur on only one phenyl ring, were more easily biodegradable). The toxicological analysis showed a reduction in the toxicity of the soil tested from toxicity unit TU = 26.7 to TU = 6.1. In addition, toxkit tests (PhytotoxkitTM and Ostracodtoxkit FTM) showed a decrease in inhibition of test organism growth from 69.3 to 14.8% (Ostracodtoxkit FTM test) and from 64.7–78.0 to 11.9–17.5% (Phytotoxkit test). Decreasing the mutagenicity index from 8.3 to 1.5 in the Ames test confirmed the effectiveness of the purification process. Based on the results of the experiment, conclusions were made regarding issues related to biodegradation of polychlorinated biphenyls in soil.
PL
W artykule przedstawiono zagadnienia związane z biodegradacją polichlorowanych bifenyli w glebie w drodze inokulacji biopreparatem IN-3, opracowanym na bazie mikroorganizmów zdolnych do metabolizowania PCB. Badania biodegradacji prowadzono metodą pryzmowania ex-situ na specjalnie do tego celu skonstruowanym stanowisku badawczym. W ramach prowadzonych badań wykonano analizy fizyczno-chemiczne gleby wyjściowej, ze szczególnym uwzględnieniem zawartości substancji biogennych (azot i fosfor), analizy chromatograficzne PCB oraz analizy toksykologiczne. Przed przystąpieniem do inokulacji gleby biopreparatem ustalono parametry prowadzenia procesu (temperatura = 17–25°C, wilgotność = 20–25%, pH = 7,5–7,8, zawartość substancji biogennych: C:N:P = 100:10:1), które kontrolowano w trakcie bioremediacji. W trakcie oczyszczania gleby prowadzono monitoring zawartości zidentyfikowanych kongenerów PCB. Ocenę skuteczności biodegradacji polichlorowanych bifenyli w glebie rozszerzono o monitoring toksykologiczny, który przeprowadzono przy użyciu żywych organizmów reprezentujących wszystkie poziomy troficzne: producentów (test PhytotoxkitTM), konsumentów (test Ostracodtoxkit FTM) i reducentów (test Microtox®SPT), a także wykonano badania obecności czynników mutagennych (test Amesa). W wyniku przeprowadzonego sześciomiesięcznego procesu biodegradacji gleby zanieczyszczonej zestarzałym olejem transformatorowym, na drodze inokulacji biopreparatem IN-3, osiągnięto obniżenie zawartości polichlorowanych bifenyli z 13 153,9 µg/kg s.m. do 1650,4 µg/kg s.m. (87,5%). Uzyskane wyniki analiz chromatograficznych wykazały, że efektywność biodegradacji PCB zależy od liczby atomów chloru w pierścieniu bifenylu (wraz ze wzrostem liczby atomów chloru w cząsteczce PCB maleje stopień biodegradacji) oraz budowy przestrzennej cząsteczki (kongenery PCB posiadające w pierścieniu bifenylu dwa lub więcej atomów chloru w pozycji ortho trudniej ulegają biodegradacji, aniżeli non-ortho lub mono-ortho, z kolei polichlorowane bifenyle, w których atomy chloru występują tylko na jednym pierścieniu fenylowym, są łatwiej biodegradowalne). Przeprowadzona analiza toksykologiczna wykazała obniżenie toksyczności badanej gleby ze stopnia toksyczności TU = 26,7 do TU = 6,1. Ponadto testy typu toxkit (PhytotoxkitTM i Ostracodtoxkit FTM) wykazały obniżenie zahamowania wzrostu organizmów testowych z 69,3% do 14,8% (test Ostracodtoxkit FTM) oraz z poziomu 64,7–78,0% do 11,9–17,5% (test PhytotoxkitTM). Obniżenie wskaźnika mutagenności z 8,3 do 1,5 w teście Amesa potwierdziło skuteczność przeprowadzonego procesu oczyszczania. Na podstawie uzyskanych wyników przeprowadzonego eksperymentu sformułowano wnioski dotyczące zagadnień związanych z biodegradacją polichlorowanych bifenyli w glebie.
EN
The present study thoroughly evaluated the eff ect of hydroxypropyl-β-cyclodextrin (HP-β-CD) on eluting of Aroclor1242 (one kind of PCBs (polychlorinated biphenyls)) from contaminated soil. The factors that might aff ect eluting effi ciency including HP-β-CD concentration, contact time, eluting cycles, temperature, pH, salt content, humic acid, and ultrasonic were all tested to evaluate the PCBs eluting effi ciency by HP-β-CD. Results indicated that Aroclor1242 can be eluted eff ectively from soil by HP-β-CD solution, 81% of Aroclor1242 was eluted from soil by 50 g/L of HP-β-CD solution after three cycles eluting, and the eluting effi ciency was improved by increasing temperature and with ultrasonic. Furthermore, it was shown that the humic acid and extreme acidic/alkaline condition both decreased the eluting effi ciency. In addition, column eluting experiment was conducted to simulate the practical HP-β-CD eluting of Aroclor1242 from contaminated soil, 18% of the PCBs was eluted from the soil column by 10 g/L of HP-β-CD. Overall, the results indicated the high extract power of HP-β-CD toward PCBs polluted soil and potential use of HP-β-CD for in situ remediation of PCBs contaminated soils.
PL
W artykule przedstawione zostały zagadnienia związane z opracowaniem metodyki chromatograficznego oznaczania polichlorowanych bifenyli w próbkach gleb. Do tego celu stosowano chromatograf gazowy wyposażony w detektor wychwytu elektronów (GC-ECD) firmy Perkin Elmer. W ramach prowadzonych badań określono optymalne parametry pracy chromatografu, takie jak: temperatura inżektora, temperatura detektora ECD, przebieg temperaturowy pieca w trakcie analizy chromatograficznej, czas analizy oraz dobrano kolumnę chromatograficzną umożliwiającą selektywny rozdział analitów. Następnie przeprowadzono kalibrację układu chromatograficznego i walidację metody analitycznej oznaczania polichlorowanych bifenyli, stosując roztwory wzorcowe firmy Supelco i Sigma-Aldrich o numerach odpowiednio 47330-U oraz 36989. Sporządzono krzywe kalibracyjne dla każdego z badanych kongenerów PCB (PCB-10, PCB-28, PCB-53, PCB-101, PCB-138, PCB-153, PCB-180, PCB-209) w dwóch zakresach stężeń. Walidacja metody analitycznej obejmowała wyznaczenie liniowości, odchylenia standardowego, względnego odchylenia standardowego, granicy wykrywalności (LOD) i granicy oznaczalności (LOQ) wyżej wymienionych kongenerów PCB. W tym celu opracowania metodyki przygotowania próbek gleb do analizy chromatograficznej przetestowano układ pod kątem doboru metody ekstrakcji (ekstrakcja rozpuszczalnikiem wspomagana wytrząsaniem, ekstrakcja z wykorzystaniem ultradźwięków i ekstrakcja w aparacie Soxhleta), doboru rozpuszczalnika/układu rozpuszczalników (n-heksan, mieszanina n-heksanu i dichlorometanu w stosunku 1:1) oraz doboru materiału sorpcyjnego w etapie ekstrakcji do fazy stałej SPE (kolumienki do zadań specjalnych oraz kolumienki z wypełnieniem Florisil). Do badań modelowych wykorzystano próbki gleb zanieczyszczone roztworem wzorcowym firmy Supelco o numerze 47330-U. Dla wszystkich kombinacji wyżej wymienionych warunków przygotowania próbki do analizy chromatograficznej obliczono stopień odzysku poszczególnych analitów. Na podstawie analiz chromatograficznych i stopni odzysku wytypowano najbardziej optymalną metodykę przygotowania próbek gleb do analizy chromatograficznej pod kątem oznaczania polichlorowanych bifenyli. Opracowaną metodykę oznaczania polichlorowanych bifenyli w próbkach gleb przetestowano na rzeczywistych próbkach gleb skażonych zestarzałym olejem transformatorowym pobranych z terenów południowo-wschodniej Polski. Procedura analityczna oznaczania PCB w próbkach gleby obejmowała: wstępne przygotowanie próbek (suszenie, mielenie i homogenizacja), izolację analitów z matrycy próbki (ekstrakcja rozpuszczalnikiem wspomagana wytrząsaniem z zastosowaniem mieszaniny rozpuszczalników n-heksan:dichlorometan w stosunku 1:1), oczyszczanie próbki z substancji przeszkadzających (zestaw dwóch kolumienek do ekstrakcji SPE: Silica gel nr 7086-03 i PCB-A nr 7511-04 firmy Bakerbond), analizę chromatograficzną. Zastosowanie wyżej wymienionych technik analitycznych pozwoliło na uzyskanie informacji na temat zawartości badanych kongenerów polichlorowanych bifenyli w próbkach gleb.
EN
The article presents issues related to the development of the chromatographic methodology for determining polychlorinated biphenyls in soil samples. For this purpose, a gas chromatograph equipped with an electron capture detector (GC-ECD) from Perkin Elmer was used. As part of the research, optimal chromatograph parameters were determined, such as injector temperature, ECD detector temperature, oven temperature course during chromatographic analysis, time of analysis and a chromatographic column allowing selective separation of analytes. Then, the chromatographic system was calibrated and the analytical method for polychlorinated biphenyls determination was validated, based on the Supelco and Sigma-Aldrich reference solutions with numbers 47330-U and 36989, respectively. Calibration curves for each of the congeners tested were PCB (PCB-10, PCB-28, PCB-53, PCB-101, PCB-138, PCB-153, PCB-180, PCB-209) in two concentration ranges. The validation of the analytical method included the determination of linearity, standard deviation, relative standard deviation, detection limit (LOD) and limit of quantification (LOQ) of the above PCB congeners. To this end, the development of the methodology for preparing soil samples for chromatographic analysis has been tested for the selection of the extraction method (extraction with solvent assisted by shaking, extraction with ultrasonic assisted solvent, solvent extraction in a Soxhlet apparatus), solvent/solvent system selection (n- hexane, a mixture of n-hexane and dichloromethane in a 1:1 ratio) and selection of sorption material in the SPE solid phase extraction stage (columns for special tasks, Florisil packed columns). Model samples used soil contaminated with the Supelco standard solution number 47330-U. For all the combinations of the above-mentioned conditions of preparing the sample for chromatographic analysis, the recovery rate of individual analytes was calculated. On the basis of chromatographic analyses and recovery levels, the most optimal methodology for preparing soil samples for chromatographic analysis was selected for the determination of polychlorinated biphenyls. The developed methodology for the determination of polychlorinated biphenyls in soil samples was tested on real samples of soils contaminated with aged transformer oil taken from the areas of south-eastern Poland. The analytical procedure for the determination of PCBs in soil samples included: initial sample preparation (drying, milling, homogenization), isolation of analytes from the sample matrix (solvent extraction assisted by shaking with a 1:1 mixture of solvents n-hexane: dichloromethane), sample purification from disturbing substances (a set of two columns for SPE extraction: Silica gel No. 7086-03 and PCB-A No. 7511-04 from Bakerbond), chromatographic analysis. The application of the above-mentioned analytical techniques allowed to obtain information on the content of polychlorinated biphenyls investigated in soils samples.
PL
Polichlorowane bifenyle (PCB), podobnie jak dioksyny oraz ich pochodne, należą do grupy związków chemicznych powszechnie uważanych za najbardziej niebezpieczne dla ludzkiego organizmu, głównie ze względu na ich właściwości fizykochemiczne, trwałość oraz odporność na degradację. Główną drogą ich absorpcji jest żywność, w której są gromadzone. Część z nich jest metabolizowana przez organizm oraz wydalana, jednak znaczna ich ilość jest akumulowana w tkance tłuszczowej. Długotrwała ekspozycja organizmu na PCB skutkuje zaburzeniami w pracy układów: nerwowego, hormonalnego, immunologicznego oraz rozrodczego. W artykule przedstawiono charakterystykę polichlorowanych bifenyli w aspekcie ich występowania w żywności oraz związanych z tym skutków.
EN
Polychlorinated biphenyls (PCB) as dioxins and their derivatives belong to a group of compounds generally regarded as the most dangerous for the human body, mainly due to their physicochemical properties, durability and resistance to degradation. They are mainly absorbed from food, in which they are collected. Some of them are metabolized by the body and excreted, but a significant amount of them is stored in adipose tissue. Long-term systemic exposure to PCBs results in disorders of the nervous, endocrine, immune and reproductive systems. The article presents the characteristics of polychlorinated biphenyls in terms of their occurrence in food and related effects.
EN
The aim of the research was to compare selected coagulants efficiency in indicator and chosen dioxin-like PCB removal from surface water. As coagulants, there were used aluminium sulfate and 5 hydrolyzed polyaluminium chlorides, with trade names: PAX-XL1, PAX-XL10, PAX-XL19, PAX-XL60, PAX-XL69. For the research, surface water was used, collected from dam reservoir. The water composition was modified with standard mixtures PCB MIX24 and MIX13, in order to obtain concentration of each congener equal to 300 ng/dm3. The PCB MIX24 mixture was composed of indicator congeners solution: 28, 52, 101, 118, 138, 153, and 180, whereas the MIX13 mixture - solution of three dioxin-like PCB 77, PCB 126, and PCB 169. It was demonstrated that the application of aluminium sulfate allowed for reaching better effects for purifying water of PCB, than with the usage of pre-hydrolyzed salts, polyaluminium chlorides. Out of the studied coagulants, the best effects for indicator PCB removal were obtained with the application of aluminium sulfate, total PCB concentration was decreased by 65%. The highest efficiency for indicator congeners removal (90%) was obtained for PCB 138 and 153. After the application of hydrolyzed polyaluminium chlorides PAX-XL1, PAX-XL10 decrease in higher chlorinated PCB concentration was obtained, in the range of 23 to 74%. Selectivity of chosen PCB congener removal, depending on applied coagulant, was demonstrated; with the usage of aluminium sulfate, removal of heptachlorobiphenyl PCB 180 at the level of 34% was obtained, whereas with the application of PAX-XL1 and PAX-XL10 higher reduction efficiency for this congener was obtained, i.e. 83 and 74% respectively. For dioxin-like PCB, after application of aluminium sulfate, total concentration reduction by 74% was obtained, efficiency of this congeners removal amounted to from 54 (PCB 77) up to 72% (PCB 126), similar results were obtained after the usage of PAX-XL1. The lowest PCB removal from water rate was stated for coagulants PAX-XL60 and PAX-XL69.
EN
The aim of the research was to compare selected coagulants efficiency in indicator and chosen dioxin-like PCB removal from surface water. As coagulants, there were used aluminium sulfate and 5 hydrolyzed polyaluminium chlorides, with trade names: PAX-XL1, PAX-XL10, PAX-XL19, PAX-XL60, PAX-XL69. For the research, surface water was used, collected from dam reservoir. The water composition was modified with standard mixtures PCB MIX24 and MIX13, in order to obtain concentration of each congener equal to 300 ng/dm3. The PCB MIX24 mixture was composed of indicator congeners solution: 28, 52, 101, 118, 138, 153, and 180, whereas the MIX13 mixture - solution of three dioxin-like PCB 77, PCB 126, and PCB 169. It was demonstrated that the application of aluminium sulfate allowed for reaching better effects for purifying water of PCB, than with the usage of pre-hydrolyzed salts, polyaluminium chlorides. Out of the studied coagulants, the best effects for indicator PCB removal were obtained with the application of aluminium sulfate, total PCB concentration was decreased by 65%. The highest efficiency for indicator congeners removal (90%) was obtained for PCB 138 and 153. After the application of hydrolyzed polyaluminium chlorides PAX-XL1, PAX-XL10 decrease in higher chlorinated PCB concentration was obtained, in the range of 23 to 74%. Selectivity of chosen PCB congener removal, depending on applied coagulant, was demonstrated; with the usage of aluminium sulfate, removal of heptachlorobiphenyl PCB 180 at the level of 34% was obtained, whereas with the application of PAX-XL1 and PAX-XL10 higher reduction efficiency for this congener was obtained, ie 83 and 74% respectively. For dioxin-like PCB, after application of aluminium sulfate, total concentration reduction by 74% was obtained, efficiency of this congeners removal amounted to from 54 (PCB 77) up to 72% (PCB 126), similar results were obtained after the usage of PAX-XL1. The lowest PCB removal from water rate was stated for coagulants PAX-XL60 and PAX-XL69.
PL
Celem badań była porównanie efektywności wybranych koagulantów w usuwaniu z wody powierzchniowej wskaźnikowych i wybranych dioksynopodobnych PCB. Jako koagulanty wykorzystano siarczan glinu oraz 5 zhydrolizowanych chlorków poliglinu o nazwach handlowych: PAX-XL1, PAX-XL10, PAX-XL19, PAX-XL60, PAX-XL69. Do badań wykorzystano wodę powierzchniową. Skład wody zmodyfikowano mieszaniną wzorcową PCB MIX24 oraz MIX13 w celu uzyskania stężenia każdego kongeneru 300 ng/dm3. Mieszaninę PCB MIX24 stanowił roztwór wskaźnikowych kongenerów: 28, 52, 101, 118, 138, 153 i 180, a mieszaninę MIX13 roztwór trzech dioksynopodobnych PCB 77, PCB 126 oraz PCB 169. Wykazano, że zastosowanie siarczan glinu pozwoliło na uzyskanie lepszych efektów oczyszczania wody z PCB niż przy wykorzystaniu wstępnie zhydrolizowanych soli, chlorków poliglinu. Z przebadanych koagulantów najlepsze efekty usuwania wskaźnikowych PCB otrzymano po zastosowaniu siarczanu glinu, sumaryczne stężenie PCB zmniejszyło się o 65%. Najwyższą efektywność usuwania wskaźnikowych kongenerów (90%) uzyskano dla PCB 138 i 153. Po zastosowaniu zhydrolizowanych chlorków poliglinu PAX-XL1, PAX-XL10 uzyskano obniżenie stężenia wyżej chlorowanych PCB w zakresie od 23 do 74%. Wykazano selektywność usuwania wybranych kongenerów PCB w zależności od zastosowanego koagulantu; przy wykorzystaniu siarczanu glinu uzyskano usunięcie heptachlorobifenylu PCB 180 na poziomie 34%, natomiast przy wykorzystaniu PAX-XL1 i PAX-XL1o uzyskano większą efektywność redukcji tego kongeneru, tj. odpowiednio 83 i 74%. Dla dioksynopodobnych PCB po zastosowaniu siarczanu glinu uzyskano redukcję sumarycznego stężenia o 74%, efektywność usuwania tych kongenerów wynosiła od 54 (PCB 77) do 72% (PCB 126), podobne rezultaty otrzymano po zastosowaniu PAX-XL1. Najmniejszy stopień usuwania PCB z wody stwierdzono dla koagulantów PAX-XL60 i PAX-XL69.
PL
W pracy przedstawiono porównanie różnych metod ekstrakcji polichlorowanych bifenyli (PCB) z osadów dennych. Zestawiono metodę ekstrakcji na gorąco, ekstrakcję ultradźwiękową, ekstrakcję poprzez wytrząsanie oraz modyfikacje tych metod. Dodatkowo ekstrahowanie próbek porównano stosując jako rozpuszczalniki n-heksan i mieszaninę n-heksan/dichlorometan. W próbkach oznaczono stężenie sześciu kongenerów dioksyn: PCB 28, PCB 52, PCB 101, PCB 138, PCB 153 i PCB 180. Analizę jakościową i ilościową wykonywano metodą chromatografii gazowej z detektorem wychwytu elektronów GC-ECD. Każda z badanych metod ekstrakcji okazała się skuteczna i selektywna dla poszczególnych PCB. Najlepsze rezultaty otrzymano ekstrahując próbkę ultradźwiękami, stosując mieszaninę rozpuszczalników n-heksan/dichlorometan.
EN
The paper presents a comparison of different methods of extraction of polychlorinated biphenyls (PCB) from the bottom sediments. High-temperature extraction, ultrasonic extraction, extraction by shaking, and modifications of these methods were tested. In addition, the extraction of the samples were compared using n-hexane and n-hexane/dichloromethane as solvents. In the samples, the concentration of the six congeners of dioxins: PCB 28, PCB 52, PCB 101, PCB 138, PCB 153, and PCB 180. Qualitative and quantitative analysis was performed by GC-ECD. Each of these methods of extraction has proven to be effective and selective for each PCB. The best results were obtained by extracting the sample in an ultrasonic using a solvent mixture of n-hexane/dichloromethane.
EN
The abiotic transformations of 2,4-dichlorophenol (DCP) and polychlorinated biphenyls (PCBs) has been examined in the presence and of zero valent iron (Fe(0)) under subcritical conditions. It was found that the degradation of DCP was significantly enhanced, showing complete degradation of DCP in 3 h at 300 °C. Control experiments without Fe(0) indicated that the removal of DCP in the iron–water system was mostly due to subcritical water oxidation and that the enhancement of degradation in the presence of Fe(0) was less significant. Regardless of Fe(0), PCBs were rapidly decomposed, showing 93% destruction in 5 h at 300 °C. Product identification by gas chromatography-mass spectrometry (GC-MS) analysis showed that the reductive transformation of DCP and PCBs w Fe(0) existed under subcritical conditions. Our results suggest that subcritical water degradation may be a possible remediation option to treat DCP and PCBs in water and soil.
EN
Management practices for medical waste should be conducted using the best available techniques in order to minimize harmful effects of medical waste. Most common practices in Turkey were reported to be burying with lime and incineration. Although incineration stood out as a better option in terms of environmental and public health, it produced air pollutants such as dioxin, furan and co-planar PCBs as a result of incomplete burning of plastics. Consequently three options, namely converter, autoclave, and ozonator technologies were investigated for economic feasibility in the medical waste treatment field. ozonator technology was concluded to be the economically best option.
EN
Effect of column bleed on trueness of determination of trace levels of dibenzofuranes (PCDD/F) and biphenyls (PCB) by gas chromatography-high-resolution mass spectrometry (GC-HRMS) was studied. As a result of extensive bleed of an arylenesiloxane capillary column, fluctuations of abundance ratios of monitored ions were observed, making exact determination of target analytes impossible. These effects were observed on food samples as well as on pure standard mixtures. The column bleed affected the abundance ratios of PCDD/F and PCB within the range of 13–328 pg of target analyte/mL, and higher levels of analytes remained intact. An analysis of diluted calibration mixtures is recommended as a tool for detection of column bleed.
18
EN
The purpose of this study is to examine the impact of mesophilic and thermophilic digestion on the content of seven congeners (with codes: 28, 52, 101, 118, 138, 153 and 180) in sewage sludge. Mesophilic fermentation occurred for 15 days at the temperature of 37oC (+/-1oC), thermophilic fermentation for 14 days at the temperature of 55oC. This study proved reduction of contents of higher chlorinated PCBs, which, under anaerobic conditions during both mesophilicand termophilic fermentation of the sludge samples, were subject to degradation to lower chlorinated congeners. During mesophilic and termophilic fermentation of the mixture of sewage sludge reduction of total content of PCBs amounted to 92,5% and 47% respectively. It is legitimate to conclude that PCB can transform both under anaerobic or aerobic conditions, which mainly involves dechlorination of higher chlorinated congeners to lower-chlorinated ones.
PL
W pracy przedstawiono wyniki badań zmian zawartości wybranych kongenerów PCB o kodach: 28, 52, 101, 118, 138, 153, 180. Przedmiotem badań były osady ściekowe pochodzące z miejskiej oczyszczalni ścieków. Prowadzono proces fermentacji mezofilowej i termofilowej. Zhydrolizowany substrat tj. mieszaninę osadów wstępnego i nadmiernego (S+N) zaszczepiono osadem fermentującym i otrzymano mieszaninę osadów (S+N+F)m. Tak przygotowany osad poddawano fermentacji metanowej mezofilowej w temperaturze 37oC (+/-1oC). Proces fermentacji termofilowej prowadzono przez 14 dni w temperaturze 55 š 1oC. Odpowiednio przygotowany osad fermentujący użyto jako materiał zaszczepiający, który zmieszano w stosunku objętościowym 1:2 z mieszaniną wstępnego z nadmiernym i otrzymano mieszaninę osadów (S+N+F)t . Badania wykazały, że zarówno fermentacja mezofilowa jak i termofilowa wpływa korzystnie na biodegradację PCB. Proces stabilizacji beztlenowej spowodował zmniejszenie stężenia siedmiu oznaczanych kongenerów PCB w mieszanie osadów (S+N+F)m oraz (S+N+F)t. Podczas fermentacji mezofilowej zmniejszenie sumarycznego stężenia PCB w mieszaninie osadów wynosiła 92,5 %, a po fermentacji termofilowej 47% Uważa się, że takie zmiany stężenia PCB były powodowane biodegradacją tych mikrozanieczyszczeń.
19
Content available remote Trwałe zanieczyszczenia organiczne w kompostach z odpadów komunalnych
PL
W niniejszym artykule podjęto zagadnienie ryzyka zanieczyszczenia kompostów przez trwałe zanieczyszczenia organiczne (TZO). Celem było wskazanie źródeł tych substancji w produkcie oraz ustalenie formalno-prawnych wytycznych dla poprawy bezpieczeństwa kompostów z odpadów.
EN
Waste composts can be efficient plant fertilizers however potential presence of toxic substances makes it necessary to control of its applicant to soil. Major organic contaminants in such products are: dioxins, polycyclic aromatic carbons and polychlorinated bifenyls. They are highly persistent in the environment, bioaccumulative and toxic. Despite this selective waste collection, good technology practice and reasonable law regulatory can support quality management of composts. Thanks to that even permanent organic contaminants can appear at the safe level in composts.
20
Content available remote Heavy metals and PCBs in sewage sludge during thermophilic digestion process
EN
The investigations were carried out in order to assess the effect of thermophilic fermentation on changes in concentration of seven congeners with codes: 28, 52, 101, 118, 138, 153 and 180 in sewage sludge. The total concentration of PCBs was the highest before the process of thermophilic fermentation. On the tenth day of the process of fermentation it was found that the total concentration of LCB doubled the previous level, whereas in higher chlorinated PCBs this value decreased twice. After the process of thermophilic digestion, all the determined congeners of PCBs were still present. However, their total concentration was reduced by 84% on the fourteenth day of the process. Low concentration of heavy metal ions in the liquid phase of sewage sludge was observed. The metal ions precipitated and remained bound throughout the stabilization process. Metal speciation analysis was performed, and revealed some changes in the chemical forms of the metals during the stabilization process of sludge. The highest increase of zinc, copper, nickel, cadmium, and chromium concentration was observed in the organic-sulfide fraction, whereas the highest increase of lead was found in the residual fraction. Thermophilic methane fermentation did not cause the accumulation of heavy metals in the mobile fractions of sludge.
PL
Przeprowadzono badania mające na celu ocenę wpływu fermentacji termofilowej na zmianę zawartości siedmiu kongenerów o kodach: 28, 52, 101, 118, 138, 153 i 180 w osadach ściekowych oraz na przemieszczanie się metali ciężkich (Zn, Cu, Ni, Pb, Cd, Cr) pomiędzy frakcjami chemicznymi osadów. Metanowej fermentacji termofilowej poddano osad pobrany z osadnika wstępnego z miejskiej mechaniczno-biologicznej oczyszczalni ścieków. Osad przed stabilizacją zmieszano w stosunku objętościowym 1:2 z osadem przefermentowanym zaadoptowanym do warunków termofilowych. Porównując sumaryczne stężenie PCB we wszystkich monitorowanych dobach procesu fermentacji termofilowej zaobserwowano, że przed procesem było ono największe. W trzeciej dobie procesu stabilizacji stężenia poszczególnych kongenerów były porównywalne natomiast w dziesiątej dobie stwierdzono, że sumaryczne stężenie niżej chlorowanych PCB wzrosło 1,5-krotnie natomiast wyżej chlorowanych zmalało około 4-krotnie. W kolejnych dobach zawartość poszczególnych kongenerów w mieszaninie osadów zmniejszała się. Po procesie fermentacji termofilowej nie oznaczono PCB 118 oraz PCB 180. W czternastej dobie procesu sumaryczne stężenie wykrytych kongenerów zmniejszyło się o 84%. Można więc przypuszczać, że proces fermentacji termofilowej nie spowodował kumulowania się polichlorowanych bifenyli w osadach ściekowych. Stwierdzono niskie stężenia jonów metali ciężkich w cieczach osadów. Jony metali wytrąciły się i pozostały związane w osadach do końca procesu stabilizacji. Najwyższy wzrost zawartości cynku, miedzi, niklu, kadmu i chromu stwierdzono we frakcji organiczno-siarczkowej, natomiast ołowiu we frakcji pozostałościowej osadów. Tym samym przeprowadzenie fermentacji osadów w termofilowym zakresie temperatur sprzyjało powstawaniu stabilnych form chemicznych metali ciężkich.
first rewind previous Strona / 3 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.