Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pollution modelling
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Development of Emission to Air in Central Europe
EN
The present state of air quality is determined according to emission and imission situation of basic pollutants. According to the obtained information about the state of air quality, the development of imission and emission presently exhibits a decreasing tendency caused especially by industrial production innovations in European countries, with slight rises in renewable energy sources for electricity production, but especially the effort to improve the condition relates to the use of mandatory quotas and pollution charges in the European Union. The aim of the this article is to review the emission development in the year 1998 up to 2013 for Central European countries – Slovakia, Czech Republic and Poland and their comparison to the European average value of the released emission. The NOx and particulate matter PM10, PM2,5 were evaluated as pollutants, which over the last few years have contaminated the air and in particular the main environment.
2
Content available remote Algorithm for HV insulator flashover under discontinuous pollution
EN
The paper presents an algorithm for predicting the behaviour of a plane insulating surface having the same critical discontinuous pollution repartition as on the 1512L cap and pin insulator, largely used in high voltage transmission lines in Algerian Sahara areas. The length of the laboratory model corresponds to the leakage path of the real insulator. The clean and the polluted bands are represented by electrical circuits. Their components are determined from experimental data. The effects of the pollution superficial conductivity on the leakage current, on the phase angle current-voltage, also on the flashover voltage and the equivalent impedance between electrodes are estimated and compared with experimental results on the laboratory model.
PL
W artykule przedstawiono algorytm opisu zjawisk na płaskiej powierzchni izolacyjnej z zabrudzeniem nieciągłym, identycznym jak na powierzchni izolatorów kołpakowych typu 1512L, stosowanych w liniach przesyłowych regionu Sahary algierskiej. Długość modelu laboratoryjnego odpowiada drodze upływu rzeczywistego izolatora. Pasma czystej i zabrudzonej powierzchni symulowane są za pomocą obwodów elektrycznych, których parametry wyznaczane są doświadczalnie. Obliczono i porównano z wynikami pomiarów na modelu laboratoryjnym wpływ przewodności powierzchniowej zabrudzenia na prąd upływu, kąt fazowy, napięcie przeskoku i impedancję zastępczą przerwy izolacyjnej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.