Materials based on polydimethylsiloxane have been developed with antibacterial activity and mechanical properties required for wound treatment. Sage herb (raw, modified, and polyphenol extract) was used as a filler in an amount of 5 and 10% by weight. Physicochemical, mechanical, and biological properties were examined. The results indicate a beneficial effect of sage modification on the tested properties.
PL
Na bazie polidimetylosiloksanu opracowano materiały o działaniu przeciwbakteryjnym i właściwościach mechanicznych wymaganych przy leczeniu ran. Jako napełniacz zastosowano ziele szałwii (surowe, modyfikowane i ekstrakt polifenolowy) w ilości 5 i 10% mas. Zbadano właściwości fizykochemiczne, mechaniczne i biologiczne. Wykazano korzystny wpływ modyfikacji szałwii na badane właściwości.
EN
Every year hundreds of serious accidents and catastrophic are accompanied by mining sector services as disaster, flooding, and demolition. To reduce the severity of the results such as high death numbers, lost communication inner and out mining, we have to find an easy way to improve communication means during that problems. In this paper, we reach out to fabricate durable, flexible, and wearable chaps, in addition to an easier carrier with highly efficient receiving and sending a signal at 2.4 GHz broad wide band. By doping a bunch of unique conductive metals (silver, copper, and gallium indium alloy) assembled on Graphene, its integration inside Polydimethylsiloxane to be future applicable antenna. Furthermore, we studied the physical and electric properties of a composite including Electrochemical Impedance properties (EIS), cyclic voltammetry (CV), and its thermal stability chip (DSC), as well as, using Transmission electron microscopy (TEM), and, scanning electron microscopy (SEM) techniques to clarify the surface morphology of fabricated materials. In addition to various measurements had been carried out such as Ultraviolet-visible, inductively coupled plasma (ICP) spectroscopy, and Energy-dispersive X-ray spectroscopy (EDX) to reinforce and elucidate the solid-state of ions inside fabricated Antenna. On the other hand, throughout stress-strain for the stretchability of fabricated is expanded to 30% of its original length, in addition to thermal stability reached to 485°C compared to pure PDMS substrate, with enhancing electric conductivity of composite ship.
PL
Większość obecnie stosowanych technik izolacji/wzbogacania analitów organicznych z próbek gazowych oraz ciekłych polega na ekstrakcji z zastosowaniem sorbentów oraz rozpuszczalników organicznych. Równie powszechne są techniki wykorzystujące adsorpcję. Jakkolwiek techniki te spełniają swoje zadanie, to jednak w praktyce wykazują istotne niedogodności. W przypadku ekstrakcji ciecz-ciecz jest to zużywanie znacznych ilości rozpuszczalników organicznych, co jest niekorzystne dla środowiska oraz podraża koszt procedury analitycznej. W przypadku technik wykorzystujących adsorbenty pojawiają się trudności z oznaczeniami dla związków polarnych o dużych masach molekularnych, kiedy pojawiają się niekorzystne zjawiska niecałkowitej desorpcji lub powstawania artefaktów. Aby ominąć te ograniczenia, opracowano szereg technik ograniczających zużycie rozpuszczalników (mikroekstrakcja do fazy ciekłej) lub całkowicie bezrozpuszczalnikowych (techniki wykorzystujące ciekłe polimery). Opracowane dotychczas techniki wykazują wiele korzystnych cech, tym niemniej mają również swoje ograniczenia. W tej pracy dokonano przeglądu szerokiego spektrum technik przygotowania próbki ze szczególnym uwzględnieniem technik o charakterze prośrodowiskowym. Opisano również techniki pod kątem wykorzystywanych mechanizmów izolacji analitów oraz stosowanych rozwiązań aparaturowych.
EN
Most of the techniques currently employed for isolation/enrichment of analytes from gaseous and liquid samples are based on partition/extraction mechanism utilizing either sorbents or liquid solvents. Adsorption based techniques are also used. All these techniques, however, reveal same drawbacks. Liquid-liquid extraction requires consumption of significant amounts of organic solvents, which is both environment unfriendly and cost - increasing. In the ease of adsorbents, same problems may arise when handling polar, high molar mass analytes, which can result in incomplete desorption and/or generating artifacts. To bypass these disadvantages, a number of new techniques have been developed, limiting solvent consumption (liquid phase microextraction) or totally solventless (utilizing liquid polymers). These new techniques offer many advantageous features, while posing same other problems. This paper presents a review of a wide spectrum of sample preparation techniques with special attention paid to environment friendly ones. The techniques are described with stressing their respective analytes isolation mechanisms and utilized instrumental designs.
5
Content available remote Microfluidic system for determination of phosphates
EN
In this work a simple and fast method of phosphates determination involving molybdenum blue has been presented. The procedure was adapted for microfluidic system under optimised experimental conditions (flow rate, temperature, wavelength). Moreover, a useful technology for the fabrication of microfluidic equipment has been proposed. Variously shaped microchannel structures were made of poly(methylmetacrylate) (PMMA) or poly(dimethylsiloxane) (PDMS) plates finely engraved with a laser beam. PDMS wafers, after their superficial oxidation in oxygen plasma, were used for sealing the channel structure. The microfluidic module outlet was connected to a Z-shape spectrophotometric flow cell used for optical detection.
PL
W artykule przedstawiono szybką i prostą metodę oznaczania jonów fosforanowych(V), opartą na reakcji tworzenia błękitu molibdenowego. Procedura analityczna została dostosowana do zaprojektowanego przez autorów mikroukładu, w którym przed właściwymi oznaczeniami przeprowadzono szereg pomiarów w celu optymalizacji parametrów eksperymentalnych, takich jak szybkość przepływu medium przez mikroukład, temperatura mikro-reaktora, długość fali. W pracy zaproponowano również technologię wykonania mikroukładów polimerowych. Struktury mikrokanatów w płytkach z polimetakrylanu metylu (PMMA) oraz polidimetylosiloksanu (PDMS) wykonano przez grawerowanie laserowe. Mikroukład uszczelniono poprzez trwałe zespolenie dwóch płytek polimerowych, których powierzchnie poddano działaniu plazmy utleniającej. Detekcję prowadzono w zaprojektowanej przez autorów spektrofotometrycznej kuwecie przepływowej, przystosowanej do pomiarów z wykorzystaniem światłowodów.
PL
Omówiono metodę oceny stopnia rozgałęzienia makrocząsteczek polimerów na podstawie pomiaru lepkości dynamicznej w zależności od szybkości ścinania (lub od częstotliwości). Sposób postępowania wymaga oznaczenia lepkości w warunkach zerowej szybkości ścinania oraz -wykorzystania zależności potęgowej wielu zmiennych w układzie zmodyfikowanych współrzędnych. Przedstawiono wyniki pomiarów i obliczeń wg równania (5) umożliwiających zastosowanie metody w wypadku poliwęglanu (PC) i polidimetylosiloksanu (PDMS). Proponowana metoda umożliwia rozróżnianie makrocząsteczek liniowych i rozgałęzionych oraz jakościowe oznaczanie stopnia rozgałęzienia. Możliwe jest także oznaczanie ilościowe, jednakże wówczas należy przeprowadzić kalibrację na podstawie próbek wzorcowych o znanym stopniu rozgałęzienia; podano tę możliwość na przykładzie poliwęglanu.
EN
Dynamic viscosity data measured in relation to shear rate (or frequency) are used to determine the zero shear rate viscosity, and a multivariable power function [1, 2] in modified coordinates is used to distinguish between linear and branched polymer molecules and to establish the degree of branching (G). The steps for quantitative evaluation of G include (i)-(v) and: (vi) plot bi vs. G by using standard samples of well-known G to ascertain the calibration dependence b1 = f(G); (vii) calculate G from the known b1 and the calibration plot of step (vi). Examples are given for polycarbonate (PC) and polydimethylsiloxane (PDMS).