The dynamic resistance measurement (DRM) method was developed as a supplementary for testing the transformer on-load tap changer (OLTC) and has become popular in recent years. The DRM method has proven to be an effective method for early detecting potential faults in tap changers. The traditional DRM method is based on a DC current being injected through a transformer winding and a tap changer as it moves from the tap to tap. The measurements are carried out in the tested transformer winding under shorted secondary winding. The article presents a new conception of the DRM method, where the OLTC condition is tested by a voltage curve, that is logged on the no-load secondary transformer winding.
PL
Metoda dynamicznego pomiaru rezystancji (DRM) została opracowana jako uzupełnienie badania przełącznika zaczepów pod obciążeniem transformatora (OLTC) i stała się popularna w ostatnich latach. Metoda DRM okazała się skuteczną metodą wczesnego wykrywania potencjalnych usterek przełączników zaczepów. Tradycyjna metoda DRM opiera się na analizie przepływu prądu stałego przez uzwojenie transformatora i przełącznik zaczepów podczas jego przełączania od zaczepu do zaczepu. Pomiary wykonywane są w badanym uzwojeniu transformatora pod zwartym uzwojeniem wtórnym. W artykule przedstawiono nową koncepcję metody DRM, w której stan przełącznika zaczepów jest badany za pomocą krzywej napięcia, która jest rejestrowana na uzwojeniu wtórnym nieobciążonego transformatora.
PL
W artykule omówiono zagadnienia związane z sieciami nn zawierającymi duże nasycenie odnawialnych źródeł energii oraz jednofazowych odbiorników generujących zakłócenia związane z wahaniami napięcia oraz asymetriami fazowymi. Omówiono regulację napięcia za pomocą podobciążeniowych przełączników mocy, układów stycznikowych oraz układów przekształtnikowych. Omówiono sposoby kompensowania zakłóceń w postaci asymetrii fazowej i międzyfazowej, w postaci transformatora symetryzującego oraz projektowanego obecnie przekształtnikowego układu regulacji napięcia.
EN
The article discusses issues related to networks LV containing high saturation of renewable energy energy sources and single-phase generating receivers disturbances related to voltage fluctuations and phase asymmetries. Regulation is discussed voltage via on-load switches power, contactor systems and converter systems. Compensation methods are discussed disturbances in the form of phase and interfacial asymmetry, in the form of a balancing transformer and currently designed converter system voltage regulation.
PL
W artykule przedstawiono zagadnienie rozwoju sieci dystrybucyjnych SN i nn z wykorzystaniem transformatorów SN/nn z podbobciążeniowymi przełącznikami zaczepów. Pokazane zostało podejście alternatywne do klasycznej rozbudowy sieci. Prezentowane podejście umożliwia obniżenie kosztów i skrócenie czasu modernizacji sieci. W artykule przedstawiono przykład rozwiązania wdrożonego w 2019 r., w sieci jednego z operatorów sieci dystrybucyjnej. Zaprezentowane zostały możliwości układu oraz omówiono zrealizowany algorytm.
EN
Issues regarding to MV&LV grid development planning with application of Voltage Regulating Distribution Transformers (VRDT) were investigated. The article presents an alternative approach to traditional network reinforcement. This approach enables the reduction of cost and time for grid upgrade. The described project has been developed in 2019 for a Polish Distribution System Operator. Opportunities of applied regulating algorithm are presented.
4
Content available remote Podobciążeniowy układ regulacji napięcia w transformatorach rozdzielczych
PL
W artykule omówiono regulację napięcia w transformatorach rozdzielczych pod obciążeniem. Przedstawione rozwiązania konstrukcyjne bazują na transformatorze dodawczym zabudowanym łącznie z transformatorem głównym w jednej kadzi. Transformator dodawczy, poprzez dobranie liczby zwojów uzwojeń i sposobu połączenia, umożliwia znaczne zmniejszenie wartości prądu w przełączanych zaczepach, tym samym umożliwia miniaturyzację stycznikowego układu przełączającego. Podano szczegóły techniczne rozwiązań. Zestawiono wnioski i literaturę.
EN
The article discusses voltage regulation in distribution transformers under load. The presented construction solutions are based on an additional transformer built-in together with the main transformer in one ladle. The addition transformer, by selecting the number of winding turns and the connection method, allows a significant reduction in the current value in the switched taps, thus enabling the miniaturization of the contactor switching system. Technical details of solutions are given. The conclusions and literature were collated.
PL
W artykule przedstawiono założenia, algorytm pracy oraz model elektromechanicznego regulatora podobciążeniowych przełączników zaczepów transformatora pracującego w trybie regulacji dolnego napięcia. Następnie model przetestowano symulacyjnie uzyskując charakterystyki czasowych. W dalszych etapach prac planowana jest walidacja eksperymentalna po implementacji modelu regulatora na wybranej platformie sprzętowej. Model ten ma służyć do badania wpływu algorytmu pracy regulatora na jakość regulacji napięcia.
EN
The article presents the created and tested model of the electromechanical tap changer. The transformer is treated as an executive element of the medium voltage control system. As the assumption, model does not take into account parallel work of transformers due to the fact that this is a very rare case. The current compensation was canceled due to the difficulty of determining the compensation impedance. For this reason, this function is deactivated in the controllers. The model assumes, according to the documentation of one of the regulators, that the characteristic is dependent on the value of the voltage error. This model is to be used to study the influence of the tap changer controller algorithm on the quality of voltage regulation. The algorithm of the classic tap changer controller has been analyzed. Important parameters of the model have been defined. The structure of the created model in Matlab-Simulink and some component blocks are presented. One of the conducted tests was shown - time characteristic t = f() of switching output relay according to changes of value of the voltage deviation.
6
PL
W artykule przedstawiono możliwości zastosowania wibroakustyki w diagnostyce podobciążeniowego przełącznika zaczepów. Zidentyfikowano korelacje występujące pomiędzy zapisem wibroakustycznym, a charakterystyką czasów własnych, a także zaprezentowano przebiegi wibroakustyczne zarejestrowane podczas pracy różnych typów podobciążeniowych przełączników zaczepów.
EN
This paper shows possibilities of vibroacoustic measurement application for diagnosis of on-load tap charger. Correlations between vibroacoustic characteristics and winding resistance measurements has been identified. Vibroacoustic characteristics recorded during the work of different types of on-load tap changers has been also presented.
PL
W artykule zaprezentowano układ regulacji napięcia po stronie SN w stacji 110/15 kV. Kierunek sterowania napięcia zależny jest od miejsca instalacji przełącznika zaczepów oraz sposobu włączenia uzwojenia regulacyjnego. Wielkościami zakłócającymi w tym układzie są zmiany wartości skutecznych napięcia zasilającego transformator i zmiany zapotrzebowania oraz zmiany generacji w sieciach SN i nn. Zaprezentowano budowę i algorytm pracy regulatora przełączników zaczepów na przykładzie regulatora URT. Zidentyfikowano wymagania i założenia dla modelu symulacyjnego utworzonego w środowisku MATLAB/Simulink. Model zostanie zbudowany w celu przeprowadzenia badań symulacyjnych wpływu rodzaju regulatora (algorytmu/ budowy) na jakość regulacji napięcia SN. Model ten umożliwi ocenę wpływu niesterowanych źródeł przyłączonych do sieci SN lub nn na jakość regulacji napięcia w tych sieciach.
EN
The article presents the voltage regulation system on the MV side of the 110 kV/15 kV station. The direction of voltage control depends on the place of installation of the tap changer and the method of switching on the control winding. The disturbing quantities in this system are changes in the voltage supplying the transformer, changes in the demand and generation balance in MV and LV networks. The construction and algorithm of the tap changer controller operation are presented on the example of the URT regulator. Requirements and assumptions for the simulation model created in Simulink were identified. The model was built to carry out simulation studies on the influence of the controller’s algorithm/construction on the quality of MV voltage regulation. In addition, this model will allow to assess the impact of unsteered sources connected to MV or LV networks on the quality of voltage regulation in these networks.
PL
W artykule przedstawiono podstawowe pojęcia związane ze stabilnością napięciową węzła sieci. Przeanalizowano wpływ regulacji przełącznika zaczepów transformatora na stabilność napięciową. Opracowano wytyczne dla regulatora przełącznika zaczepów ze względu na krytyczne możliwe obniżenie się zapasu stabilności napięciowej.
EN
The paper presents the basic concepts associated with the stability of the voltage. The influence of regulating transformer on the voltage stability. Developed guidelines for the regulator tap changer due to a critical decrease in the supply voltage stability.
PL
W artykule przedstawiono doświadczenia innogy Stoen Operator po zainstalowaniu dwóch układów do kształtowania obciążeń odbiorców zasilanych z sieci niskiego napięcia. Na kompletny pojedynczy zestaw składa się sterownik FBVR oparty na układach telemechaniki z zaimplementowanymi algorytmami sterowniczymi, transformator 15/0,4 kV z podobciążeniowym przełącznikiem zaczepów (PPZ) oraz sensory napięcia na końcach wybranych obwodów nN zasilanych z tej stacji. Omówione zostały funkcjonalności układu, doświadczenia z instalacji oraz perspektywy wykorzystania i szanse rozbudowy.
EN
Experiences with installation of two low voltage grid loads forming systems were presented in the paper. Single system includes FBVR controller with implemented algorithms, MV/LV transformer with onload tap changer and voltage sensors at the ends of selected LV feeders. Functionalities, experiences of installation, application perspectives and development opportunities were described.
EN
The paper presents the designs of classic and solid-state tap-changers for HV/MV regulating transformers. A simulation model was designed to assess the quality of voltage regulation with an on-load tap-changer. Disruption in this model is represented by a change in the demand and supply voltage of the transformer. Based on simulation studies, the paper presents the comparative characteristics of classic and solid-state tap-changers. The effect of replacing the classical tap-changer switch with a solid-state one on the regulator synthesis was also studied. Based on the analyses above new options of regulation with solid-state tap-changers have been formulated. The purpose of this paper is to determine the requirements for this new type of regulator for solid-state tap-changers and possible criteria for the operation of this control mechanism.
PL
W artykule przedstawiono konstrukcje klasycznego oraz półprzewodnikowych przełączników zaczepów dla transformatorów regulacyjnych WN/SN. Zaprojektowano model symulacyjny do oceny jakości regulacji napięcia za pomocą podobciążeniowego przełącznika zaczepów (PZ). Zakłóceniem w tym modelu są zmiany zapotrzebowania oraz zmiany napięcia zasilania transformatora. W artykule na podstawie badań symulacyjnych zaprezentowano charakterystykę porównawczą klasycznych przełączników zaczepów oraz półprzewodnikowych. Zbadano również, jaki wpływ na syntezę regulatora ma zmiana klasycznego przełącznika na półprzewodnikowy. Na podstawie ww. analiz sformułowano nowe możliwości regulacji z półprzewodnikowymi przełącznikami zaczepów. Celem artykułu jest określenie wymagań dla nowego typu regulatora półprzewodnikowych przełączników zaczepów oraz możliwych kryteriów działania tej regulacji.
11
Content available remote Zastosowanie analizy DGA do oceny stanu technicznego PPZ
PL
W artykule omówiono różne przypadki uszkodzeń w przełącznikach zaczepów i przedstawiono wyniki badan gazów rozpuszczonych w oleju. Przedstawiono również stosowane metody oceny defektów w przełącznikach zaczepów przedstawione w opracowaniu CIGRE .W pracy zaprezentowano skrótowo klasyfikację PPZ w zależności od ich konstrukcji oraz wykorzystanych układów elektrycznych. Zaprezentowano sposób identyfikacji uszkodzeń PPZ przy użyciu trójkąta Duvala w zależności od rodzaju konstrukcji przełącznika zaczepów.
EN
This article presents different OLTC`s damages with its DGA results. It shows also some methods for OLTC`s defects interpretation presented in CIGRE brochure. It gives classification of OLTC`s in accordance to their construction and electrical system used.
PL
W artykule przedstawiono praktyczny przykład diagnostyki podobciążeniowych przełączników zaczepów (PPZ) z wykorzystaniem metody emisji akustycznej (EA). Badania przeprowadzono dla zestawu trzech przełączników jednofazowych typu 3xVRC I 701 zainstalowanych w trójfazowym transformatorze o mocy 12 MVA. Pomiary wykonano dla jednostki nowej na stacji prób. Analizę uzyskanych wyników wykonano w dziedzinie czasowej i czasowo – częstotliwościowej. Opis sygnałów EA generowanych przez PPZ w dziedzinie czasowej wykonano za pomocą przebiegów czasowych, modułu transformaty Hilberta i czasów charakterystycznych. W dziedzinie czasowo – częstotliwościowej mierzone sygnały opisano za pomocą spektrogramów widma gęstości mocy przy wykorzystaniu krótkoczasowej transformaty Fouriera. Dodatkowo wyniki pomiarów uzyskanych metodą emisji akustycznej porównano z rezultatami badań oscylograficznych.
EN
In this paper, practical example of application of acoustic emission method (AE) to on-load tap changer diagnostics (OLTC) is presented. Research was performed on three single phase OLTCs of 3xVRC I 701 type, mounted in three-phase transformed which rated power is 12 MVA. Measurements were carried out in manufacturers transformers test facility for brand new unit. Analysis of obtained results was performed in time and time-frequency domains. In time domain, EA signals generated by OLTC were described by its time-amplitude composition, Hilbert transform modulus and characteristic times. In time-frequency domain measured signals were described by power spectral density obtained by application of short-time Fourier transform. Additionally, results of measurements obtained with application of EA method were compared with results obtained with oscilographic analysis.
PL
Tematyka artykułu związana jest z opracowaniem nowej metody diagnostyki stanu technicznego podobciążeniowych przełączników zaczepów (PPZ). Proponowana metoda bazuje na wykorzystaniu sygnałów emisji akustycznej (EA) generowanych przez PPZ. W artykule przedstawiono praktyczny przykład zastosowania metody EA do oceny stanu technicznego trójfazowych PPZ charakteryzujących się konstrukcją zosobnym przełącznikiem mocy i wybierakiem.
EN
Subject of this article is connected with development of new on-load tap changers (OLTCs) diagnostic method. Proposed method is based on usage of acoustic emission (AE) signals generated by OLTC. This article presents practical example of application AE method to evaluate technical condition of OLTCs build as three phase units with separate power switch and tap selector.
PL
W niniejszym artykule zaprezentowano wyniki analizy sygnałów emisji akustycznej generowanej przez pracujący podobciążeniowy przełącznik zaczepów (PPZ) transformatora energetycznego. Przedstawiono charakterystyczne cechy sygnałów rejestrowanych różnymi czujnikami pomiarowymi oraz omówiono możliwości zastosowania prezentowanej metody do diagnostyki PPZ w warunkach przemysłowych.
EN
This paper presents results of analysis of acoustic emission (AE) generated by operating power transformers on-load tap changer (OLTC). Characteristic features of AE signals recorded by different types of sensors are described. Possible applications of discussed method to diagnose technical condition of OLTC in industrial conditions are presented.