1
Content available remote Voltage/current control mode for combined three-phase inverter
EN
For parallel inverters system, controlling the output voltage in normal operation constantly is named the voltage control mode (VCM), and controlling the output current constantly in abnormal operation conditions (such as short circuit) is named the current control mode (CCM). The combined three-phase inverter topology is presented, the equivalent inverter topology with a LCL filter is obtained and mathematical models are built in VCM and CCM. A hybrid control strategy is proposed. The PID control and the repetitive control are used in VCM to obtain the fast dynamic responses and low harmonic distortions. On the other hand, the state feedback control is used in CCM. Pole assignment has been employed in designing parameter of the PID controller and state feedback, and the repetitive control design process is given. Experimental results validate the proposed control using two 400KVA parallel inverters.
PL
Dla równoległego systemu przekształtników zazwyczaj stosuje się system kontroli napięcia VCM i system kontroli prądu CCM (w warunkach specjalnych - np. zwarcia). Zaprezentowano topologie przekształtnika trójfazowego. Odpowiednia topologia przekształtnika z filtrem LCL została przedstawiona. Zaproponowano hybrydową strategię sterowania. System PID sterowania użyty w VCM zapewnia szybką odpowiedź dynamiczną i małe zniekształcenia. W układzie CCM użyto stałego sprzężenia zwrotnego. Sprawdzono położenie biegunów. Wyniki eksperymentu z dwoma 400kVA równoległymi przekształtnikami potwierdziły założenia.
EN
This paper presents the application of active control system to reduce the vibration and the sound radiation of a circular plate which is fluid-loaded and clamped at a finite baffle. The plate is driven by a uniform harmonic primary force and controlled by a distributed secondary force generated by the piezodisks. The aim of the paper is to design a controller to modify the response of the plant in some desired fashion. The mathematical model of the system includes the influence the acoustic wave radiated by the plate, Kelvin-Voigt damping in the plate material and viscous fluid damping. For the considered system the transfer function of controller of 4th order, satisfying the polynomial Diofantine equation, is derived. The influence of the fluid-loading and damping effects on the system response are presented graphically and discussed. The results show that plate modes have been reduced very well by obtained controller for a few assumed values of damping coefficients.
PL
W pracy przedstawiono zastosowanie aktywnego sterowania do redukcji drgań i fal akustycznych promieniowanych przez płytę kołową utwierdzoną na obwodzie. Płyta pobudzana jest do drgań siłą harmoniczną o rozkładzie równomiernym, a sterowana za pomocą pary piezodysków PZT. Celem pracy jest zaprojektowanie układu sterowania, który modyfikuje odpowiedź obiektu w pożądany sposób. Model matematyczny rozważanego obiektu uwzględnia oddziaływanie zwrotne fali akustycznej, tłumienie wewnętrzne materiału oraz tłumienie wiskotyczne. Dla zastosowanego modelu wyznaczono transmitancję regulatora czwartego rzędu, rozwiązując równanie diofantyczne. Wpływ tłumienia wewnętrznego, wiskotycznego oraz sprzężenia pomiędzy drgającą strukturą i ośrodkiem na odpowiedź układu przedstawiono w sposób graficzny i przeanalizowano. Otrzymane wyniki pokazują, że zaprojektowany regulator bardzo dobrze tłumi drgania płyty dla kilku założonych wartości współczynników tłumienia.