Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pletyzmografia
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The thermal environment in the workplace is an important factor which affects workers’ health. During 2011 in Poland, 14,781 workers were exposed to a cold working environment, i.e., 3.8% of persons employed in hazardous work conditions. The aim of this study was to determine the cardiovascular response to continuous (4 °C for 60 min) and intermittent (10 min at 4 °C and 10 min at room temperature alternately) exposure to the cold in 30 healthy men aged 20–27 years. Peripheral blood flow was assessed with impedance plethysmography. Heart rate and arterial blood pressure were monitored with the Holter system. Having assessed the results, it is difficult to say which kind of exposure has a more severe impact on the cardiovascular system. Longer observation and a more detailed analysis would be necessary (e.g., Doppler echocardiography).
EN
The aim of the study was to determine the cardiovascular response to continuous (4 °C for 60 min) and intermittent (10 min at 4 °C and 10 min at room temperature alternately) exposure to the cold in 30 healthy young men. The subjects were equipped with a set of identical clothing (insulation 2.1 clo) and during the stay in the chamber and outside performed the same activities, i.e., walking on a treadmill at a speed of 0.5 km/h. The tests included assessing the central circulatory system using the Holter system and assessing the peripheral circulatory system using impedance plethysmography and Doppler ultrasound. The analysis of the parameters that describe the central and peripheral circulation poses a difficulty in determining which variant of exposure constitutes a greater load on the circulatory system. It should be noted that even the conditions used in the study may cause adverse effects in the cardiovascular system.
EN
The aim of this study is the processing and evaluating of plethysmographical records giving important information about the blood vessel function. Result of this study is to present the methodology for classifying the records by means of mathematical methods that would contribute to systematic evaluation of what has been found by finger plethysmography. Thereafter the experimental expert system based on framework systems serves to determine the diagnosis on the basis of previous mathematical processing is introduced. The goal of the project was also creation of application by the form of the extension of kernel for the use of framework that is determined for support of control and information systems development in the area of signal processing, elaborate and describe the methodology of extension hereof setting in the nature of specific applications. Beyond above-mentioned outputs the solution of the project should give the specific knowledge about the usage effectiveness of evolutional frameworks. Fundamental implementation idea is based on the usage of MATLAB as the basis for extension of common kernel.
first rewind previous Strona / 1 next fast forward last