Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  plazma sprzężona indukcyjnie
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote A global model for the inductively coupled rf discharges in Ar/H2 mixture
EN
This paper presents the simulation of the rf Inductively Coupled Plasma (ICP) characteristics in the Ar/H2 mixture at low pressure, within a cylindrical stainless steel chamber. The global model used in this study and implemented on the COMSOL Multiphysics software, is elaborated under four main components: The fluid model for plasma species is associated with the electromagnetic equations for the calculation of the electric field using the magnetic vector potential. Moreover, since the plasma is weakly ionized, the properties of the neutral gas species must be taken into account by using the Navier-Stokes equation to describe the gas flow and the heat transfer equation to calculate the gas heating due to elastic collisions between electrons and neutrals. In this work, the model is first applied in order to understand the physical and chemical processes in the Ar/H2 plasmas. The properties of plasma species in the mixture are second investigated as a function of hydrogen fraction assuming the Maxwellian electron energy distribution. The theoretical interpretations of the obtained results are also addressed in this paper.
PL
W artykule przedstawiono symulację właściwości rf plazmy sprzężonej indukcyjnie (ICP) w mieszaninie Ar / H2 pod niskim ciśnieniem, w cylindrycznej komorze ze stali nierdzewnej. Model globalny zastosowany w tym badaniu i wdrożony w oprogramowaniu COMSOL Multiphysics jest opracowany w ramach czterech głównych komponentów: Model płynu dla form plazmy jest powiązany z równaniami elektromagnetycznymi służącymi do obliczania pola elektrycznego z wykorzystaniem potencjału wektora magnetycznego. Ponadto, ponieważ plazma jest słabo zjonizowana, należy wziąć pod uwagę właściwości obojętnych form gazu, stosując równanie Naviera-Stokesa do opisu przepływu gazu oraz równanie przenoszenia ciepła, aby obliczyć nagrzewanie gazu w wyniku zderzeń sprężystych między elektronami. W tej pracy model został po raz pierwszy zastosowany w celu zrozumienia procesów fizycznych i chemicznych zachodzących w plazmie ArH2.
PL
Opracowano szybką i dokładną metodę analizy pierwiastków głównych, podrzędnych i śladowych w próbkach ołowiu i jego stopów techniką plazmową ICP-AES. Badania obejmowały dobór odpowiedniej procedury roztwarzania próbek, optymalizację parametrów pomiaru, określenie rodzaju interferencji oraz wyznaczenie charakterystyki metrologicznej metody. Na podstawie przeprowadzonych eksperymentów, analizy certyfikowanych materiałów odniesienia oraz porównaniu z powszechnie stosowaną techniką HEPS-OES można stwierdzić, że opracowana metoda pozwala na uzyskanie wiarygodnych wyników oznaczenia Sb, As, Sn, Ag, Cu, Bi, Zn, Ni i Cd z zadowalającą precyzją (RSD ≤ 1,7%).
EN
At. emission spectroscopy with inductively coupled plasma was used for fast detn. of Sb, As, Sn, Ag, Cu, Bi, Zn, Ni and Cd contents in certified ultra pure Pb and 4 ref. Pb alloys to prove applicability of the method. The metal samples were dissolved in soln. of HNO₃ and L(+) tartaric acid. The limits of detection and quantification, linear dynamic range, repeatability, reproducibility and accuracy were detd. The results were highly consistent with ref. values (reproducibility 1.7% for all detd. components).
EN
An experimental amangement for multielement microanalysis of solid samples by laser ablation-inductively coupled plasma/microwave induced plasma - optical emission spectrometry (LA-ICPIMIP-OES) is introduced. A laser ablation unit - ICPIMIP, an "ablation - excitation" separated tandem source (STS) bas been assembled from commercially available instruments, viz, a laser microprobe and ICP echelle spectrometer, together with MIP system and an interface.
PL
Opisano system aparaturowy techniki sprzężonej, w której skład wchodzą: laserowa ablacja (odparowanie), optyczny spektrometr emisyjny, dwa źródła wzbudzenia (ICPIMIP) i układ optyczny między plazmą szczeliną wejściową spektrometru.
EN
Trace elements from waste activated sludges application can accumulate in the soil. In order to evaluate beneficial agronomic and adversely environmental effects of these materials, knowing the chemical composition of waste activated sludges is of great importance in agricultural use of these wastes. The aim of this study was to determine the total content of lithium, barium and strontium in waste activated sludge produced in the sewage purification plant of meat processing factory in Sokolow Podlaski. 20 samples were collected periodically, at biweekly intervals, from March to December in 2005. Total content of Li, Ba and Sr was determined using inductively coupled plasma atomic emission spectrometry (ICP-AES). The data were processed statistically using means, percentiles, and concentration ranges. Due to the variability of trace elements content in waste activated sludge within sample collection date a single factor analysis of variance was completed. It was found that the total content of lithium, barium and strontium in the analyzed sludge was low and this material could be used as soil amendment.
PL
Pierwiastki śladowe zawarte w osadach ściekowych stosowanych w celach nawozowych mogą ulegać akumulacji w glebie. Aby ocenić korzystne właściwości nawozowe oraz zagrożenia dla środowiska wynikającego z rolniczego użytkowania osadów, niezbędna jest znajomość składu chemicznego tych odpadów. Celem niniejszej pracy było przedstawienie ogólnej zawartości litu, baru i strontu w osadach ściekowych wytworzonych w oczyszczalni ścieków zakładów mięsnych w Sokołowie Podlaskim. Do badań wybrano 20 próbek osadu ściekowego pobranych od marca do grudnia 2005 r. w odstępach dwutygodniowych. W próbkach oznaczono całkowitą zawartość litu, baru i strontu metodą atomowej spektrometrii emisyjnej ze wzbudzeniem w plazmie sprzężonej indukcyjnie (ICP-AES). Uzyskane dane opracowano statystycznie, przedstawiając zawartości wybranych pierwiastków śladowych jako średnie, percentyle oraz zakresy stężeń. Wykazano istotne różnice w zawartościach wybranych pierwiastków śladowych, w zależności od terminu pobrania próbki, przez jednoczynnikową analizę wariancji. Stwierdzono, że całkowita zawartość litu, baru i strontu w próbkach osadów ściekowych była relatywnie mała, co pozwala na rolnicze wykorzystanie tych odpadów.
EN
Plasma spectrometric techniques: inductively coupled plasma-atomic emission spectrometry (ICP-AES) and inductively coupled plasma-mass spectrometry (ICP-MS) are rapidly becoming the most important analytical tools for the determination of trace amounts of elements. High speed, excellent detection limits, wide dynamic range and possibility of accurate multi-element analysis make the techniques particularly suited to the determination of ppb and sub-ppb levels of the analytes in complex matrices. Mass spectrometric methods offer unique capability of rapid isotopic ratios measurements. Plasma techniques have found wide applications in analysis of geological, environmental and clinical samples. They have proved to be very useful in speciation studies due to extremely low sensitivities offered and the ease of on-line combination with separation techniques, in particular with chromatography. A brief review of ICP-AES and ICP-MS techniques is presented in the paper. The possibility and limitations of the techniques as analytical tools are discussed. The most important analytical parameters are collected in Table 1. Detailed characteristics of equipment used: sample introduction systems, analyzers and detectors are given. The discussion of experimental parameters, including the choice of analytical wavelengths (ICP-AES) and isotopes (ICP-MS), is presented. The main physical, matrix, chemical and spectral interferences occurring in analysis of real samples are characterized.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.