The size and distribution of water demand within a given structural unit is the basis for the proper operation and planning of the expansion and modernization of the water supply system’s elements. In rural areas, particularly in municipalities adjacent to urban-industrial agglomerations, a change in the use of tap water has been increasingly observed. The water consumption for animal breeding or agricultural use, typical of these areas, has been decreasing and even disappearing. Water has been increasingly used for domestic purposes in single- and multi-family housing as well as for other purposes such as watering lawns and filling residential swimming pools. Taking this into account, this paper presents observations regarding daily water consumption in a municipality adjacent to Wrocław together with an analysis of the possibility of using the exponential smoothing method for the short-term forecasting of daily water consumption. The analyses presented in this paper were carried out using STATISTICA 13 software.
PL
Wzrost zapotrzebowania na wodę w gminach przyległych do dużych aglomeracji, a co za tym idzie wzrost produkcji wody, zmuszają przedsiębiorstwa wodociągowe do szukania nowych rozwiązań dotyczących między innymi optymalnego sterowania takimi procesami jak: ujmowanie i rozdział dyspozycyjnych zasobów wodnych, dystrybucja oraz oczyszczanie wody i ścieków. Aby zapewnić skuteczne sterowanie tymi procesami wymagany jest między innymi skalibrowany model hydrauliczny sieci dystrybucji i model prognostyczny poboru wody. Do bieżącego i krótkoterminowego prognozowania poboru wody wykorzystywane są modele stochastyczne, wprowadzane w postaci zalgorytmizowanej do struktury zarządzania procesem sterowania. Najczęściej stosowane są scałkowane modele autoregresji i średniej ruchomej ARIMA oraz metody wygładzania wykładniczego szeregów czasowych. Modele klasy ARIMA odwzorowują właściwości statyczne i dynamiczne szeregów stacjonarnych i pewnych klas szeregów niestacjonarnych, interpretowanych jako wynik przejścia białego szumu przez dyskretny filtr liniowy skończenie wymiarowy. Charakteryzują się one różnymi właściwościami przy jednolitym zapisie formalnym oraz identycznych metodach estymacji parametrów dla różnych typów i podklas modeli. Metody prognozowania oparte na algorytmach wygładzania wykładniczego są łatwe do praktycznego zastosowania i nie wymagają założenia o stacjonarności analizowanego szeregu czasowego. W niniejszej pracy przedstawiono obserwacje dotyczące dobowego zużycia wody w jednej z gmin przyległej do Wrocławia wraz z analizą możliwości zastosowania metody wygładzania wykładniczego do krótkoterminowego prognozowania dobowego poboru wody.
2
Content available remote Regionalne dysparytety rozwoju infrastruktury wodociągowej
PL
Przedstawiono wybrane wyniki badań modelowych, dotyczących optymalizacji hydraulicznej działania cylindrycznych i stożkowych regulatorów hydrodynamicznych. Zbadane zależności funkcyjne umożliwiają racjonalny dobór parametrów konstrukcyjnych przedmiotowych regulatorów ze względu na maksymalizację efektu dławienia strumienia cieczy.
EN
Extensive range of water supply infrastructure development differences in the regional water supply system based on CSO data on the state in 2009. Indices wire length distribution pipe network. Water consumption in households, the impact of a truer level of water charges and liquidation depersonification consumption.
PL
Postępujący proces urbanizacji wymusza zajmowanie coraz to nowych terenów pod budownictwo mieszkaniowe i przemysłowe. Rozwój terytorialny miast powoduje, że tereny te kolidują często z wodociągowymi przewodami tranzytowymi. Przewody te często mają dużą średnicę i pracują pod wysokim ciśnieniem. Konsekwencje awarii takich przewodów, przebiegających przez tereny zabudowy, mogą być znaczne. W związku z tym należy zastanowić się nad określeniem powierzchni strefy ochronnej, na której terenie zabronione byłoby budownictwo komunalne i przemysłowe. W artykule przedstawiono propozycję metody wyznaczania zasięgu strefy ochrony dla przewodów tranzytowych w wybranym mieście Polski. Przewód o średnicy 1,0 m transportuje wodę ze zbiorników wyrównawczych do sieci miejskiej. Proponowana metoda korzysta z określania zasięgu pełnego nasycenia gruntu w bezpośrednim sąsiedztwie przewodów przy założeniu jego awarii. Jako granicę czasową symulacji przyjęto moment wypływu wody na powierzchnię. W prezentowanych badaniach stosowano program narzędziowy FEFLOW, korzystający z metody elementów skończonych. Badania symulacyjne zostały wykonane na podstawie rozpoznania geotechnicznego gruntu, zawartego w projekcie technicznym rurociągu.
EN
The constant urbanisation process provides to occupation of new territories for housing and industry constructions. Territorial growth of the cities causes, that inside their new zones can lay the water transit pipes. Their main aim is water transit from intakes or storage tanks to distribution systems. Very often they have a big diameter and work under high pressure. The break-down of such pipes causes essential consequences, especially in urbanised zones. From that point of view there is necessary to take into consideration the implementation of protection zones, where communal and industrial construction would be prohibited. In the paper the proposition of the new method of protection zones is presented. All divagations based on selected Polish city conditions. Water transit pipe has 1.0 m diameter. It transports the water from storage tanks to distribution system. Proposed method bases on the calculations of full saturation ground range in the neighbourhood of the pipes. The two types of pipe damages, longitude and cross-section breaks were assumed. As the time limit of the simulations the water outflow on the ground surface has been taken. The investigations presented in the paper, base on the FEFLOW program which uses finite element method. Simulations have been done under conditions of geotechnical profiles received from the technical documentation of conduit construction. Simulation results are completed by two methods of additional protection, which can be used in the neighbourhood of transit pipes at the city housing or industrial zones.
EN
Making use of the results of many year observations and in-service studies, analyses were per- formed and generalizations were made regarding the reliability of the water-pipe networks of Brzeg, Kłodzko, Oleśnica, Opole and two regions of the city of Wrocław. The contribution of reduced pressure head and reduced daily variations in the forcing pressure at the pumping stations to the rate of pipe failure was quantified. Taking into account the results of water loss analysis for the water-pipe networks under study, the effects of pipe failure were assessed. A correlation was found to occur between water loss, water pipe loading, failure rate and maximal head of the forcing pressure at the pumping station.
PL
W artykule przedstawiono charakterystykę istniejącego systemu zaopatrzenia w wodę w miejscowości Krosno Odrzańskie. Przy pomocy programu Epanet wykonano obliczenia pozwalające na ocenę warunków pracy sieci, a sformułowane wnioski zastosowano do przeprowadzenia obliczeń symulacyjnych.
EN
Characteristic of exploited water supply system in Krosno Odrzanskie in this paper was shown. Calculations were made by means of Epanet and their results were applied to simulation calculations.
EN
An analysis of water management during one calendar year in four selected rural waterworks located in Lesser Poland voivodeship was conducted. On the basis of available data, the amount of water loss and its financial consequences were defined. Water loss in the water-pipe networks of interest ranged between 5.1 and 49.7% of water pumped into the system causing a financial loss from 3.7 to 70.6 thousand zł/year. Computed loss ratios were compared with Polish and international standards. Moreover, technical and organizational solutions limiting water loss were described which mostly include water-pipe network renovation using thermoplastic materials and the replacement of old indoor plumbing.
PL
Dokonano analizy gospodarowania wodą w ciągu jednego roku kalendarzowego w czterech wybra-nych wodociągach wiejskich w województwie małopolskim. Na podstawie dostępnych danych określono wielkość strat wody i ich skutki finansowe. Straty wody w analizowanych wodociągach wyniosły od 5,1 do 49,7% ilości wody wtłoczonej do sieci, co skutkowało stratą finansową od 3,7 do 70,6 tys. zł/rok. Obliczone wskaźniki strat odniesiono do standardów polskich i międzynarodowych. Wskazano także możliwości techniczno-organizacyjne ograniczenia strat wody, do których zaliczono przede wszystkim systematyczną renowację sieci wodociągowych z wykorzystaniem tworzyw termoplastycznych oraz wy-mianę starego uzbrojenia sieci na nowoczesne o wysokich walorach technicznych i użytkowych.
PL
W pracy wykazano, że zużycie wody w miastach polskich ma charakter zmienny w czasie, ze zdecydowanie spadkową tendencją. Badania przeprowadzono na podstawie danych z 80 miast o liczbie mieszkańców od kilku do kilkuset tysięcy. Zebrane dane pozwoliły na określenie tendencji zmian zużycia wody w czasie, jednostkowego zużycia wody przez mieszkańców korzystających z wodociągu oraz współczynników nierównomierności poboru wody - dobowego i miesięcznego. Wyniki badań mogą być wykorzystane do oceny pracy miejskich systemów wodociągowych oraz do planowania ich rozbudowy.
EN
It has been demonstrated that water consumption in Poland's towns and cities follows a time-related pattern with a visible downward trend. This study was conducted for 80 Polish towns with a population varying between several thousand and several hundred thousand. With the data sets obtained it was possible to determine the time trend of changes, unit water consumption per user of the water-pipe network, and the coefficients of irregularity in daily and monthly water demand. The results of the study can be of use in performance analysis of municipal water supply systems, or when planning the development of water-pipe networks.