Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  pierwiastki alkaliczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The aim of the study was to evaluate the contents of alkaline elements in soil and hay obtained from grass with respect to the possibility of their use as a fuel in furnaces of power engineering industry. Two significantly different types of grass were used in the investigation: Miscanthus sacchariflorus and Calamagrostis epigejos. The experiment was started on typical for the northen part of the Lublin region podsolic soils that belong to quality class IVb, in the objects of Łęczyńska Energetyka in KWK Bogdanka. The plants were cultivated in conditions similar to these used during their production cultivation, but without the traditional mineral fertilization, which was replaced with post-sewage waters from the local, industrial, mechanical-biological sewage plant. The study revealed that both types of grass bad useful properties for burning biomass, because they contained limited amounts of alkaline elements, however, there was a significant discrepancy in absorption of alkaline elements by both grasses.
PL
Celem przeprowadzonych badań była ocena zawartości pierwiastków zasadowych w glebie i sianie traw w kon-tekście możliwości ich wykorzystania jako paliwa w piecach energetyki zawodowej. W badaniach wykorzystano 2 gatunki zdecydowanie różniących się traw: Miscanthus sacchariflorus oraz Calamagrostis epigejos. Doświadczenie założono na typowych dla północnej części Lubelszczyzny glebach bielicowych zaliczanych do IVb klasy bonitacyjnej w obiektach należących do Łęczyńskiej Energetyki w KWK Bogdanka. Rośliny uprawiane były w warunkach zbliżonych do produkcyjnych, ale bez tradycyjnego nawożenia mineralnego, które było zastąpione wodami pościelowymi z miejscowej oczyszczalni przemysłowej typu mechaniczno-biologicznego. Przeprowadzone badania wykazały, że obie trawy charakteryzują właściwości przydatne do spalania biomasy, bowiem zawierają ograniczone ilości pierwiastków zasadowych, przy czym wystąpiło wyraźne zróżnicowanie pobierania poszczególnych pierwiastków alkalicznych przez obie trawy.
EN
The main figures of merit of a simultaneous spectrometer with photodiode array (PDA) detector and low power (275 W; 27.12 MHz) and Ar consumption (0.4 L min(-1)) radiofre-quency capacitively coupled plasma source for simultaneous determination of some alkaline and alkaline-earth elements (Li, Na, K, Ca) are presented. The torch has a molybdenum tubular electrode and a single (SRT) or double ring electrode (DRT) distanced at 60 mm. The simultaneous spectrometer equipped with PDA detector (200-1100 nm) has a 95 mm Paschen-Runge mount. For the best geometry of the plasma (DRT configuration), the limits of detection are: 30 (Li); 40 (Na); 60 (K) ng mL(-1) and 210; 100; 210; 90 ng mL(-1) for Ca(II)393.3 nm, Ca(I) 422.7 nm, CaOH 554 nm and CaOH 622 nm. The recovery degree of Ca in certified plasma sera was 99.4š1.4 % and RSD 3.8-4,9%. In the determination of Ca in five blood samples the RSD was 2.9-4.4%.
PL
Zaprezentowano wielkości charakterystyczne spektrometru z detektorem mozaikowym (PDA) i źródłem wzbudzenia plazmy malej mocy (275 W; 27.12 MHz) przy zużyciu argonu 0.4 L min(-1), do jednoczesnego oznaczania niektórych pierwiastków alkalicznych i ziem alkalicznych (Li, Na, K, Ca). Palnik wyposażony był w molibdenową elektrodę rurową i jedno- (SRT) lub dwupierścieniową (DRT) elektrodę umieszczoną w odległości 60 mm. Równoczesny spektrometr z detektorem PDA (200-1100 nm) pracuje w 95 nm układzie Paschena-Runge'a. Przy najlepszej geometrii plazmy (konfiguracja DRT) granice detekcji wynosiły: 30 (Li); 40 (Na); 60 (K) ngmL(-1) oraz 210; 100:210; 90 ugraL(-1) dla Ca(II) 393.3 nm, Ca(I) 422.7 nm, CaOH 554 nm i CaOH 622 nm. Odzysk Ca w certyfikowanych surowicach wyniósł 99.4š1.4 % a względne odchylenie standardowe 3.8-4.9%. Podczas oznaczania Ca w pięciu próbkach krwi względne odchylenie standardowe wyniosło 2.9-4.4%.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.