Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 14

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  photovoltaic conversion
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents statistical analysis of measurement results of electrical parameters for photovoltaic modules installed in stationary and dual-axis configurations. The parameters which were taken into account included: coefficient of variation, skewness and standard deviation. Also a correlation was determined between independent variables such as insolation, sunshine duration, cloudiness, ambient temperature and atmospheric pressure, and the dependent variable in the form of the daily electricity from photovoltaic conversion. In order to determine the repeatability of electricity waveforms occurring between summer months as well as between summer and winter months, the non-parametric U Mann-Whitney test was used. In order to analyse the repeatability of daily peak hours in which the highest value of the hourly electricity production is observed, the non-parametric Kruskal-Wallis test was used. The tested systems were connected to the power grid and operated independently. Test stands consisting of polycrystalline photovoltaic modules, single-phase on-grid inverters, irradiance sensors and a temperature recorder, were located on the building rooftop of the Faculty of Control Robotics and Electrical Engineering of the Poznan University of Technology in Poland (Central Poland, 52°24.4152′N, 16°55.7958′E) at the height of 30 metres above the ground level. A significant increase in the production of electricity using the PV module spatial positioning system was demonstrated in relation to modules based on the year-round modified design.
EN
The article presents theoretical foundations of a two-diode equivalent model of a photovoltaic cell/module (PV), together with calculation procedures. A physical interpretation of individual components of an equivalent model was presented. Its practical application in predicting efficiency of operation of various PV cells and modules in low insulation conditions was demonstrated. The obtained predictions were verified with the actual results of their operation in open space (outdoor). The practical suitability of the “model” in early detection of ageing phenomena, such as, for example, absorber degradation taking place in PV modules, was demonstrated. The article was prepared on the basis of the results of testing five different PV modules with various constructions, made of different materials and absorbers, such as: c-Si, mc-Si, CIS, a-Si_SJ, a-Si_TJ. The used measurement data were collected during the 16-year period of the experimental PV modules testing system operation in University of Opole, equipped with a data acquisition system.
EN
The article presents theoretical foundations of application of the reduced I-V Blaesser’s characteristics in predicting a photovoltaic cell/module (PV) efficiency, together with calculation procedures. A detailed analysis of the error of this transformation method of characteristics was carried out. Its practical application in predicting efficiency of operation of various PV cells and modules in medium and high insulation conditions was demonstrated. The practical suitability of the presented method in early detection of ageing phenomena, such as, for example, absorber degradation taking place in PV modules, was demonstrated. The article was prepared on the basis of the results of testing five different PV modules with various constructions, made of different materials and absorbers, such as: c-Si, mc-Si, CIS, a-Si_SJ, a-Si_TJ. The used measurement data were collected during the 16-year period of the experimental PV modules testing system operation in Opole University, equipped with a data acquisition system.
PL
W pracy przedstawiono całoroczną analizę numeryczną efektywności energetycznej dwóch eksperymentalnych fasad fotowoltaicznych, południowej i północnej, budynku biurowo-przemysłowego w Warszawie. Do obliczeń wykorzystano program symulacyjny ESP-r. Zastosowano dwa różne rozwiązania konstrukcyjne fasad eksperymentalnych. Energia wyprodukowana przez panele fotowoltaiczne została przeznaczona na zapewnienie zapotrzebowania energetycznego na potrzeby oświetlenia i wentylacji pomieszczeń biurowych. Analiza wykazała, że latem zastosowane systemy fotowoltaiczne generują nadwyżkę energii elektrycznej, natomiast zimą, zwłaszcza w listopadzie i grudniu, zapotrzebowanie energetyczne na wentylację i oświetlenie przewyższa wydajność eksperymentalnych fasad fotowoltaicznych.
EN
The paper presents the whole year numerical analysis of the energy efficiency of the two experimental south and north oriented photovoltaic facades of the office and industrial building in Warsaw. Calculations were done using simulation program ESP-r. Two different constructions of the experimental facades were applied. The energy produced by the photovoltaic panels was intended to provide the energy demand for artificial lighting and ventilation in office rooms. The analysis showed that in the summer the photovoltaic systems generate surplus of electricity, while in winter, especially in November and December, the energy demand for ventilation and lighting exceeds the production capacity of photovoltaic facades.
5
Content available remote The use of fuel cells to store energy from renewable sources
EN
The paper characterizes the design, operation, classification and application of fuel cells and presents a proposal of an analysis of the cooperation of a laboratory hydrogen fuel cell with photovoltaic modules that constitute the power source for an electrolyser. The results of the tests conducted can constitute a substantive teaching basis.
PL
W pracy scharakteryzowano budowę, zasadę działania, klasyfikację i zastosowania ogniw paliwowych oraz przedstawiono propozycję analizy współpracy laboratoryjnego ogniwa wodorowego z modułami fotowoltaicznymi, stanowiącymi źródło zasilania dla elektrolizera. Wyniki przeprowadzonych doświadczeń mogą stanowić merytoryczną bazę w dydaktyce.
EN
The study compares the production of electric power and energy in the two photovoltaic systems working independently: -fixed, with one angle setting during the year, -two-axis tracking. The analyzed systems are located in Poznan, at an altitude of about 25 meters above the ground (the roof of the Faculty of Electrical Engineering building - Poznan University of Technology) and equipped with photovoltaic modules using the same polycrystalline technology and characterized by the same capacity. Distribution of power density of solar radiation on the surface of both PV modules was examined and the production of electricity from photovoltaic conversion between the two approaches was compared.
PL
W pracy porównano produkcję mocy i energii elektrycznej w dwóch pracujących niezależnie od siebie układach fotowoltaicznych: - stacjonarnym, o jednym całorocznym ustawieniu kątowym, - nadążnym dwuosiowym. Analizowane układy zlokalizowane są w Poznaniu na wysokości około 25 metrów nad poziomem gruntu (dach Wydziału Elektrycznego Politechniki Poznańskiej) i wyposażone w moduły fotowoltaiczne, wykonane w tej samej technologii polikrystalicznej i charakteryzujące się tą samą mocą. Zbadano rozkład gęstości mocy promieniowania słonecznego na powierzchni obu modułów PV i porównano produkcję energii elektrycznej w wyniku konwersji fotowoltaicznej w obu rozwiązaniach.
7
EN
The paper presents the results of the research carried out in summer periods in 2011 and 2012 for two geographical locations, i.e. Poznań (Poland) with geographic coordinates 52°24'30"N, 16°56'3"E and Playa del Ingles (Gran Canaria, Spain) - 27°45'24''N and 15°34'43''W, and for various time coordinates (within day and year scale), with consideration of the angle of receiver inclination with respect to the horizon and with various azimuth angles. Differences in solar radiation were considered in the research. The results so obtained give evidence of usefulness of the use of the follow-up systems in our weather conditions in order to achieve optimal values of power density of the radiation.
PL
W pracy przedstawiono wyniki badań przeprowadzonych w okresie letnim 2011 i 2012 roku dla dwóch lokalizacji geograficznych Poznań (Poland) o współrzędnych geograficznych 52°24'30"N i 16°56'3"E oraz Playa del Ingles (Gran Canaria Spain) - odpowiednio - 27°45'24'' N i 15°34'43'' W oraz różnych współrzędnych czasowych (w skali dnia i roku), z uwzględnieniem zmian kąta pochylenia odbiornika do horyzontu jak i zmian kąta azymutu. Uwzględniono przy tym zróżnicowaną intensywność promieniowania słonecznego. Uzyskane wyniki wskazują na celowość stosowania układów nadążnych w naszych warunkach klimatycznych dla uzyskania optymalnych wartości gęstości mocy promieniowania.
EN
Paper presents the influence of external conditions such as: the latitude φ, the solar declination δ, the hour angle ω, number of sunny hours, cloud cover and orientation of photovoltaic module on the energetic gain. The results of the measurements of radiation power density that reaches the surface of the PV receiver for its different positions, for the geographic location of the cities of Poznań and Playa del Ingles and for different time periods (yearly and daily) are presented in a graphical form. The study compares also production of electric power and energy in different weather conditions: cloudy, partly cloudy and cloudless sky using two- axis tracking system and fixed with one optimal angle setting during the year. Analyzed systems are located in Poznan on the roof of the Faculty of Electrical Engineering building. Distribution of power density of solar radiation in different days of the year was also compared.
PL
Obecnie poszukuje się czystych ekologicznie, a jednocześnie odnawialnych źródeł energii. Jedną z ich form jest konwersja fotowoltaiczna z wykorzystaniem fotomodułów. Jednak o możliwości efektywnego wykorzystania tej formy pozyskiwania energii decydują warunki klimatyczne, takie jak: nasłonecznienie, usłonecznienie, ilość opadów, jak również i skład atmosfery ziemskiej. Polska, a w szczególności rejon południowo-wschodni odznacza się dobrymi parametrami do zastosowania tej formy pozyskiwania energii zarówno z wykorzystaniem konwerterów fototermicznych jak i fotowoltaicznych. W artykule przedstawiono analizę wpływu temperatury na wydajność konwersji fotowoltaicznej w warunkach południowo-wschodniej Polski.
EN
Currently there are looking for a clean and at the same time renewable energy sources . One of them forms is photovoltaic conversion using PV modules. However, the possibility of effective use of this form of energy production determine the climatic conditions such as sunlight, sunshine, rainfall, as well as the composition of Earth's atmosphere. Poland, in particular the region of south-east of Poland is characterized by good parameters to use this form of energy production from both the converters - using solar photothermal collectors and photovoltaic modules. This paper presents an analysis of the influence of temperature on photovoltaic conversion efficiency in conditions of Southeastern Poland.
10
Content available remote Odnawialne źródła energii a ogniwo paliwowe PEM - wybrane zagadnienia
PL
Odnawialne źródła energii stosowane do produkcji energii elektrycznej są jednym ze sposobów ograniczenia emitowanego CO2 przez człowieka do atmosfery. Ze względu na niestabilność dopływu energii z takich źródeł, np. energii promieniowania słonecznego, konieczne jest odpowiednie zmagazynowanie pozyskanej energii. Jedną z możliwości jest produkcja i magazynowanie wodoru, który w zależności od zapotrzebowania będzie utleniany w ogniwach paliwowych. W artykule przedstawiono wybrane zagadnienia związane z produkcją wodoru do ogniw paliwowych typu PEM, Zastosowanie urządzeń bezpośredniej przemiany takich jak ogniwa fotowoltaiczne pozwala na stworzenie stosunkowo sprawnych i nieskomplikowanych w eksploatacji układów wykorzystujących energię Słońca do produkcji wodoru w elektrolizerach.
EN
Renewable in use energy sources to production the electrical energy are one from way of the reduction emitted CO2 through man to the atmosphere. In view of the instability of the flow of the energy from such sources, eg. the energy of the solar radiation, is necessary suitable storing of gained over energy. One from the possibility is the production and the storage of hydrogen which in the dependence from the application will be oxidized in fuel cells. In the article one introduced chosen connected problems with the production of hydrogen to fuel cells of the type PEM, the Use of de vices of the direct transformation such how photo voltaic cells lets on the creation of relatively efficient and simple in operation of system using the energy of the Sun to production hydrogen in electrolysers.
PL
Przedstawiono program obliczeń i analizę bilansu energii w samochodzie zasilanym energią pozyskiwaną w wyniku konwersji fotowoltaicznej i z akumulatorów.
EN
The paper presents software for analysis of energy balance in a bartery car with bartery charged by photovoltaic converter.
PL
Przeprowadzono analizę rozdziału mocy w samochodzie słonecznym, w tym zapotrzebowania na moc uwarunkowanego koniecznością pokonania przez pojazd oporów: toczenia i aerodynamicznego, w funkcji jego parametrów konstrukcyjnych i eksploatacyjnych jak i możliwości pozyskania energii z konwersji fotowoltaicznej i - uzupełniającej z akumulatora. W rozważaniach uwzględniono wpływ nasłonecznienia, to, czy pojazd znajduje się w ruchu, czy podczas postoju, a także sprawność poszczególnych elementów napędu.
EN
Analysis of power distribution in a solar car was carried out, inclusive of the power demand related to the need of overcoming rolling and aerodynamic resistance with respect to its structural and operational parameters and the possibility of obtaining the power of photovoltaic conversion aided by an accumulator battery. The consideration takes into account the insolation, the fact whether the vehicle is moving or remains immobile, and the efficiency of particular parts of the drive.
14
PL
W pracy przedstawiono wyniki dwuletniej analizy funkcjonowania systemu solarnego Instytutu Fizyki Politechniki Lubelskiej. System ten wykorzystuje równocześnie dwa rodzaje konwersji - fototermiczną i fotowoltaiczną. Do analizy wykorzystano autorski system monitoringu.
EN
This work presents two years analysis of functioning of solar system in Institute of Physics of Lublin University of Technology. This system uses two types of solar energy conversion - phototermal and photovoltaic. The original system of monitoring was used.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.