The paper presents method for thermal generation reduction in low level light applications, especially where measured phenomena have random character. The algorithm was developed basing on cosmic ray measurements. The main parts of the system are: Silicon Photomultipliers (SiPM), front-end ASIC for amplifying and shaping signals. SiPM is a very sensitive device which can detect single photons. Comparing to a standard photomultiplier SiPM has a compact size, low operating voltage and it is immune to an electromagnetic field. Thermally generated signals are disadvantage of SiPM. This paper presents the measurement method to reduce influence of thermal generation.
EN
This paper presents the method for the compensation of the temperature fluctuations in the measurement system based on the Silicon Photomultipliers (SiPM). Temperature has very strong influence on the gain of the detectors. Because single photons are detected and the system is very sensitive, its parameters have to be steady during the measurements. Temperature is being stabilized by changeable bias voltage of the detector. This paper describes how the algorithm of compensation has been determined during series of measurements and presents first results of temperature compensation.
PL
Artykuł opisuje metodę kompensacji zmian temperatury w systemach pomiarowych zawierających krzemowe fotopowielacze. Temperatura ma duży wpływ na wzmocnienie krzemowego fotopowielacza. Ponieważ urządzenie to jest bardzo czułe i potrafi mierzyć pojedyncze fotony, jego parametry muszą być kontrolowane podczas pomiaru. Temperatura jest stabilizowana przez zmiany napięcia polaryzacji. Artykuł prezentuje opis opracowania metody kompensacji na podstawie pomiarów oraz pierwsze wyniki kompensacji temperatury.
EN
This paper presents an efficient measurement system for a low-level light detection, emitted by fluorescent dye. The system setup and measuring method has been discussed. Silicon photomultiplier, which is called Multi Pixel Photon Counter developed by Hamamatsu, has been used as a light detector. Tests has been done for fluorescein and resorufin specimens in 1.5 ml volume PMMA (Polymethyl Methacrylate) cuvettes positioned in a specially designed optical system. Solutions of this dyes were prepared in TRIS buffer with pH factor equal 8. Range of concentrations which has been used for measurements is from 1ug/ml to about 1 pg/ml.
PL
Artykuł przedstawia efektywny system pomiarowy do detekcji światła fluorescencyjnego o niskim natężeniu. Została w nim omówiona konstrukcja systemu oraz metoda pomiarowa. Jako czujnik światła fluorescencyjnego użyty został fotopowielacz krzemowy produkowany przez firmę Hamamatsu. Testy wykonano na próbkach fluoresceiny i rezorufiny umieszczonych w kuwetkach PMMA o pojemności 1,5 ml. Roztwory tych barwników przygotowano w roztworze TRIS o czynniku pH = 8. Stężenia barwników w roztworach, wykorzystane podczas pomiarów zawierają się w przedziale od 1ug/ml do około 1 pg/ml.
EN
This paper presents data acquisition system for Silicon Photomultiplier (SiPM), with four channels front-end ASIC implemented in 0.35 µm CMOS AMS technology. The signal from SiPM is shaped in front-end ASIC, converted to a digital value and processed in FPGA. The paper discusses principles of work, results of device measurements and data analysis.
PL
Artykuł ten prezentuje system akwizycji danych dla krzemowych fotopowielaczy (SiPM), który wykorzystuje czterokanałowy układ scalony ASIC zaimplementowany w technologii CMOS AMS 0,35 µm. Sygnał pochodzący z SiPM jest kształtowany w układzie ASIC, następnie konwertowany na postać cyfrową i poddawany dalszej obróbce w układzie FPGA. Artykuł omawia zasadę działania systemu, wyniki przeprowadzonych badań oraz analizę danych.