Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 29

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  phase shift
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
1
EN
This paper presents an inexpensive, high-performance STM32-based software phase-locked loop (PLL) system suitable for seriesresonant inverters (SRIs) with various control methods. The paper shows how to achieve high resolution in setting the voltage-current time-shift with the proposed PLL using the microcontroller of the STM32G4x4 line, shows the features of the operation and implementation of this PLL. The proposed software PLL is implemented in the same microcontroller that controls the SRI output current, which makes it possible to simplify the structure of the SRI control system.
PL
W niniejszym artykule przedstawiono niedrogi, wysokowydajny system oparty na oprogramowaniu STM32 z pętlą synchronizacji fazowej (PLL), odpowiedni dla falowników rezonansowych (SRI) z różnymi metodami sterowania. Artykuł pokazuje jak osiągnąć wysoką rozdzielczość w ustawianiu przesunięcia czasowo-prądowego z proponowanym PLL z wykorzystaniem mikrokontrolera linii STM32G4x4, pokazuje cechy działania i realizacji tego PLL. Proponowane oprogramowanie PLL jest zaimplementowane w tym samym mikrokontrolerze, który steruje prądem wyjściowym SRI, co pozwala na uproszczenie struktury układu sterowania SRI.
EN
In this paper, we design and analyse the Circuit for Grover’s Quantum Search Algorithm on 2, 3 and 4-qubit systems, n terms of number of gates, representation of state vectors and measurement probability for the state vectors. We designed, examined and simulated the quantum circuit on IBM Q platform using Quantum Programming Studio. We present the theoretical implementation of the search algorithm on different qubit systems. We observe that our circuit design for 2 and 4-qubit systems are precise and do not introduce any error while experiencing a small error to our design of 3-qubit quantum system.
3
Content available remote Flow structure investigation over a pool-rife sequence in a variable width river
EN
A comprehensive overview of flow characteristics in natural channels with bedforms is a vital issue in river management projects. Pool-rife sequences as common bedforms in the gravel-bed rivers significantly impact flow characteristics and turbulence intensity. The present study was taken by field investigation in the Babolroud River, Iran. A 95 m reach with variable width was chosen in this river and velocity components and shear stress were obtained in different sections. Quadrant analysis was also applied to determine the dominant bursting event in the pool section. The results revealed a phase shift for stream-wise velocity, near-bed velocities, and bed shear stress versus bed profile. In the pool, vertical velocity components were oriented downward near the bed and upward near the water surface, while in the rife section vectors were oriented towards the bed. The findings of quadrant analysis demonstrated the ejections and sweeps as a dominant event close to the bed and water surface, respectively.
PL
W artykule przedstawiono charakterystyki warunkowych wartości średnich w zastosowaniu do pomiaru kąta przesunięcia fazowego pomiędzy dwoma sygnałami sinusoidalnymi o tej samej częstotliwości. Omówiono wpływ zniekształceń i zakłóceń harmonicznych na dokładność pomiaru. Podano przykłady eksperymentalne oraz podsumowanie.
EN
The article presents the characteristics of the conditional average values used to measure the phase shift angle between two sinusoidal signals of the same frequency. The impact of interferences and harmonic distortions on measurement accuracy was discussed. Examples of experiments and a summary were provided.
EN
Structures and characteristics of wideband small-size phase shifters made with the use of single parallel stubs are presented in this paper. The stubs can be short-circuited or open-circuited on termination. Such devices are well known, but are primarily used as components of filters or matching circuits. The novelty, then, comes from the establishment of simple, but helpful formulae, which enable to describe the insertion phase shift and differential phase shift of a line with short and open stubs connected in parallel. These equations can be very useful for designing complex microwave multi-ports. The results of simulations and measurements of the devices, which were designed and made, are shown herein. It was also proved that the presented device shave several usable operating frequency sub-bands, and that the differential phase shift values in the higher sub-bands are greater than those in the lower operating frequency ranges. Thanks to this, the described phase shifters can be used in more than one frequency sub-band. It was stated that in the conditions under analysis, larger phase shifts can be achieved using open-circuited stubs rather than short-circuited stubs. However, the phase shifters with shorted parallel stubs can operate in a wider frequency band.
EN
Proposed method of leakage identification uses a parametric model in the form of signals phase shift (φ). Signals from the test stand will be used: r1, r2 - signals from the corrective elements connected to the tested pipeline, pressure signals x, mass flow y and simulated mass flow yw. For these signals, their auto and cross power spectral densities are determined: Sxx, Syy, Srr, Sxy, Sxr, Syr, which are the basis to determine spectral transfer functions described as the relations between these signals and next the phase shifts (φ). Thanks that, we get a large set of transfer functions, hence a large set of phase shifts between the measured.
PL
Zaproponowana metoda wykorzystuje model parametryczny w postaci różnicy przesunięć fazowych sygnałów (φ). Wykorzystane zostaną sygnały ze stanowiska laboratoryjnego: r1 i r2 – sygnały z korektorów dołączonych do rurociągu, ciśnienie x, masowe natężenie przepływu y oraz symulowane masowe natężenie wypływu yw. Dla tych sygnałów wyznacza się gęstości widmowe mocy własne i wzajemne: Sxx, Syy, Srr, Sxy, Sxr, Syr itp., a następnie transmitancje widmowe opisujące relacje między tymi sygnałami oraz ich przesunięcia fazowe (φ). Dzięki temu otrzymuje się liczny zbiór transmitancji, a stąd liczny zbiór przesunięć fazowych między mierzonymi sygnałami.
EN
Experimental and Numerical studies were carried out on turbulent heat transfer and friction factor loss through a triangular chevron channel. For uniform wall heat flux equal 1350 (W/m²) using air as a working fluid. Reynolds number varied from 3000 to 10000, phase shifted at the range of 0≤ϕ≤180, with variation distance between chevron surfaces (5 ≤ D ≤ 35 mm). Nu increased and TEF decreased in increasing of Re. The TEF and Nu increased with closing to channel phase shift angle 90˚, the best performance was noticed on phase shift, ϕ=90º. At the end of this paper effect of distance between chevron surfaces presented, The TEF and Nu increased with decreasing to channel distance and the best performance was noticed on closing to D=5(mm).
8
Content available remote Adaptive slip&slide control system design in railway applications
EN
Adhesion coefficient and the resultant normal force occurred at the wheel-rail contact determine braking and traction forces in railway applications. Due to the limits on controlling the resultant normal force, maximization of the adhesion coefficient is the only way to obtain larger braking and tractive works. There are various advantages of utilization of adhesion in an efficient way, such as reducing operating costs, minimizing trip time, preventing wheel-rail wear. On the other hand, the adhesion mechanism at the wheel-rail contact has a highly non-linear complex nature, whose dynamics are changed as a function of parameters like environmental conditions, vehicle speed, slip ratio etc. There is not any satisfactory accurate and trustworthy way of estimating these parameters yet. In this paper, an event based adaptive control scheme has been introduced to maximize the adhesion coefficient without requiring the exact value of those parameters. The efficient adhesion utilization can be obtained by using the proposed method while maintaining the stability. The continuous excitement of traction system and slow recuperation detection time difficulties in the former research has been overcome. The dynamics of phase shift were analyzed and an adaptive structure were built. Results acquired by using the proposed adaptive method were compared with the conventional control scheme in “Matlab&Simulink” software under various driving scenarios and wheel-rail contact conditions.
EN
An important problem in the operation of gas pipelines is the identification of accidental gas leakage from the damaged pipeline. It is the hardest when the leakage is small. A disadvantage of prior methods is that with their use is only possible to identify and locate significant outflow with only a low accuracy. In proposed method of identifying the gas flow will be used a new signal from the corrective element “r” attached to the tested pipeline and calculated from it and mass flow rate signals auto and cross power spectral density Sxx, Syy, Srr, Sxy, Sxr, Syr. Using the power spectral density signals allows for transition from the signal diagnostic to the parameter diagnostic which is more effective. Assumptions methods will be verified at the experimental station.
PL
Ważnym problemem w procesie eksploatacji gazociągów jest identyfikacja przypadkowego wypływu gazu z uszkodzonego gazociągu. Największą trudność sprawia lokalizacja i identyfikacja wycieku, gdy jest on mały. Wadą dotychczasowych metod jest to, że przy ich użyciu możliwe jest jedynie identyfikowanie znacznych wypływów i lokalizowanie ich tylko ze zgrubną dokładnością. W zaproponowanej metodzie identyfikacji wypływu gazu zostanie wykorzystany nowy sygnał z korektora r dołączonego do badanego gazociągu oraz gęstości widmowe mocy sygnałów własne Sxx, Syy, Srr i wzajemne Sxy, Sxr, Syr (gdzie y to sygnał z dowolnego czujnika ciśnienia lub masowego natężenia przepływu). Wykorzystanie do analizy mocy sygnałów pozwoli na przejście od diagnostyki sygnałowej do diagnostyki parametrycznej, która jest skuteczniejsza. Założenia metody zostaną zweryfikowane na stanowisku eksperymentalnym.
EN
A measurement method of sine voltage phase shift disturbed with noise using conditional averaging of the delayed signal module was proposed. The advantages of the proposed principle were indicated. The results of basic experiments confirming the obtained theoretical results were also provided.
PL
Zaproponowano metodę pomiaru przesunięcia fazowego napięcia sinusoidalnego zakłóconego szumem, wykorzystującą warunkowe uśrednianie modułu sygnału opóźnionego. Podano i analizowano modele teoretyczne pomiaru. Pokazano korzystne cechy zaproponowanej zasady. Zamieszczono wyniki podstawowych eksperymentów potwierdzające uzyskane wyniki teoretyczne.
EN
The article presents an analysis of the technical condition of the two blades with different technical conditions (for medium and low wear). It is shown that the evaluation of the blades basis only on the endoscopic research does not provide full information about the technical condition (known only the external condition of the blades). Proposed supplement endoscopic examinations of is the use of two parametric methods (the blades are tested during operation of rotating machine) based on the auto and cross power spectral density functions for the signal measured as displacement of the rotor blade tip y(t). As result of these methods is the portrait of the blades was obtained (in the form of clear colour images providing a degree of a wear), which also includes the internal condition of the blades. The additional complement to parametric methods may be nonparametric method. Auto and cross power spectral density functions (obtained from measurement of the blade tip movement) is a basis to determine the characteristics (abstract step and impulse responses) of each blade. Both parametric methods which nonparametric method clearly confirmed that the technical condition of first considered blade (no. 2) differs from the technical condition of the second blade (no. 22).
12
Content available remote Estymacja kąta przesunięcia fazowego przy nagrzewaniu indukcyjnym w.cz.
PL
W artykule przedstawiono wybrane cyfrowe metody pomiaru kąta przesunięcia fazowego: czasową, opartą na detekcji przejścia przez zero oraz dwie częstotliwościowe, opartą na transformacie Fouriera i opartą na transformacie Hilberta. Przedstawiono wyniki weryfikacji eksperymentalnej metod w dwóch różnych układach pomiarowych pod kątem możliwości ich wykorzystania w odniesieniu do sygnałów w.cz. przy nagrzewaniu indukcyjnym rejestrowanych z niskimi częstotliwościami próbkowania.
EN
In the paper chosen digital methods of phase shift determination are presented: one operating in the time domain (based on zero crossing detection), and two operating in frequency domain (Fourier transform and Hilbert transform based). The results of the experimental verification of above mentioned methods in two different measurement systems are presented. The main focus was to verify the possibility of their use for the signals of induction heating equipments recorded with the low sampling frequencies.
PL
W rzeczywistych elementach maszynowych często występują złożone stany obciążenia takie jak zginanie ze skręcaniem, stąd zachodzi konieczność weryfikacji istniejących modeli opisujących trwałość zmęczeniową w zakresie propagacji pęknięć zmęczeniowych. Celem pracy jest szczegółowa analiza wpływu kąta fazowego przesunięcia φ na trwałość zmęczeniową Nf próbek w procesie inicjacji i propagacji pęknięć zmęczeniowych. Do modelowania trwałości obliczeniowej posłużono się modelami Parisa, Formana, Dowlinga-Begleya i Gasiaka-Rozumka. Trwałości obliczeniowe Nfobl, wyznaczone według tych modeli, uzyskano stosując metody numeryczne.
14
EN
This paper presents new approach to impedance spectroscopy measurements based on Fast Fourier Transform in biological application. The proposed solution uses a current excitation, which is continuous in a finite frequency range. The electrical response of tissue is measured using proposed circuit by two separate digital-to-analog converters. The impedance spectrum and the phase shift are computed by differentiation of complex spectrum obtained from FFT algorithm. The proposed method was simulated using state space representation and the results were presented.
PL
Artykuł przedstawia nową metodę wyznaczania spektrum impedancji opartą o dyskretną transformatę Fouriera. W proponowanym rozwiązaniu zastosowano wymuszenie prądowe, którego widmo jest ciągłe w skończonym przedziale częstotliwości. Do pomiaru odpowiedzi elektrycznej tkanki został zaproponowany układ pomiarowy oparty na dwóch równoległych przetworniki analogowo-cyfrowe. Wyznaczanie spektrum impedancji oraz przesunięcia fazowego obliczane jest na podstawie różnic między widmami uzyskanymi z algorytmu FFT. Proponowana metoda została zasymulowana z zastosowaniem równań stanu, wyniki zostały umieszczone w opracowaniu.
EN
A novel identical multiple wavelength sampled fiber Bragg grating (FBG) is proposed. A phase shift between the two adjacent FBG units is achieved by increasing the direct current (DC) refractive index of the FBG. The FBG with identical reflective spectrum is optimized with a designed sampling function. DC phase shift FBGs are analyzed and fabricated, which shows a good agreement with a discrete phase shift method. A dual-wavelength (DW) filter with channel spacing 0.16 nm is fabricated, and the experiment results verified the feasibility of this proposed method. A four-wavelength filter with channel spacing 0.16 nm is then proposed and demonstrated. This method has the following advantages: wavelength design is flexible, fabrication precision and costs are low.
PL
W artykule przedstawiono zasadę działania i budowę układów przeznaczonych do wyznaczania kąta przesunięcia fazowego wirujących elementów urządzeń mechatronicznych oraz ich przemieszczeń względnych w ruchu prostoliniowym. Pomiary dokonywane są za pomocą inkrementalnych przetworników obrotowo-impulsowych oraz specjalnie opracowanych układów cyfrowych. Układy mogą być przydatne w procesach pomiarów i synchronizacji różnych przebiegów w budowie i eksploatacji maszyn a zwłaszcza w technice aktywnego tłumienia drgań.
EN
The article presents the principle of operation and construction of systems for determining the phase angle of rotating machinery components and their relative displacement in the linear motion. The measurements are made through incremental rotary pulse transducers, and specially designed digital circuits. Systems can be useful in the processes of measurement and synchronization of different waveforms in the construction and operation of machines and especially in the technique of active vibration damping.
EN
A novel approach to implement high channel-count comb filters based on a DC phase shift is proposed. Various channel spacings can be achieved by a single chirped phase mask and a submicrometer-precision translation stage. Simulation and experiment show that arbitrary phase shifts introduced by DC refractive index modulation can be achieved. An multichannel comb filter with channel spacing of 100 GHz, 50 GHz and 40 GHz is implemented with the same phase mask. A comparison between the proposed DC phase shift and traditional discrete phase shift is made.
EN
This article presents tests results of monitoring technical condition of turbomachine blades. The method is based on a diagnostic model fi T12,T01 that utilizes the difference of phase shift of signals that are the result of blade operation y(t) and a signal x(t) of its environment described with appropriate distribution when the blade moves away from the sensor and when the blade tip approaches the sensor. The adopted diagnostic model indirectly takes into account present blade environment x(t) without the need to measure it [13,15]. The results of diagnosing three blades (worn out to a great extent, considerably worn out and worn out to a little extent) with the use of different distribution courses were presented. Shown results differ to a little extent from each other. However, they unequivocally specify the character of blade wear. Thus, the choice of distribution that represents non-measurable blade environment while determining parameters of a model fi T12,T01 for evaluation of technical condition of working turbomachine is optional and limited only by observation time.
EN
This paper presents the bases of a new method of monitoring technical condition of turbomachine blades during their operation. The method utilizes diagnostic models such as a quotient of amplitude amplification and a phase shift of diagnostic signal y(t) which is a result of blade operation as well as a signal x(t) of blade environment while a blade tip approaches a sensor, amplitude amplification and phase shift of these signals while the blade tip moves away from the sensor. The adopted diagnostic models indirectly take into account the existing environment of a blade, represented by the signal x(t), without the need to measure it. Thus, the model is sensitive to the changes in technical condition of blades and practically intensive to a change in environment. The suggested method may prove very important in diagnostics of rotor blades during turbomachines operation (compressors, turbines etc.).
PL
W artykule przedstawiono podstawy nowej metody monitorowania stanu technicznego łopatek maszyn wirnikowych podczas ich użytkowania. Metoda wykorzystuje modele diagnostyczne w postaci ilorazu wzmocnienia amplitudowego i przesunięcia fazowego sygnału diagnostycznego y(t) wynikającego z działania łopatki i sygnału x(t) jej otoczenia podczas zbliżania się wierzchołka łopatki do czujnika i wzmocnienia amplitudowego i przesunięcia fazowego tych sygnałów podczas oddalania się wierzchołka łopatki od czujnika. Przyjęte modele diagnostyczne pośrednio uwzględnia aktualne otoczenie łopatki x(t) bez konieczności jego pomiaru. Zatem jest on czuły na zmiany stanu technicznego łopatki, a mało wrażliwy na zmianę otoczenia. Proponowana metoda może odegrać istotną rolę w diagnostyce łopatek wirnikowych podczas użytkowania maszyn wirnikowych (sprężarek, turbin, itp.).
20
Content available remote Przyrząd wirtualny do wyznaczania różnicy faz dwóch sygnałów napięciowych
PL
W artykule przedstawiono przyrząd wirtualny do wyznaczania wartości różnicy faz dwóch sygnałów napięciowych realizujący pomiar przy wykorzystaniu karty pomiarowej z jednym przetwornikiem analogowo-cyfrowym. Przyrząd posiada dwie możliwości pomiaru różnicy faz. Pierwsza z nich wykorzystuje aproksymację jednego z sygnałów, natomiast w drugiej wykorzystano zewnętrzny układ próbkująco-pamiętający. Zbudowany przyrząd umożliwia sprawdzenie działania algorytmu przy użyciu symulowanego sygnału wejściowego.
EN
The paper present the virtual instrument for evaluation the phase difference of two voltage signals that realize the measurement using of data acquisition card with one analog to digital converter. Built instrument has implemented two possibilities to phase difference measure. In the first method the approximation of one of the signals is used, however in the second method external sample-hold is used. Moreover, built virtual instrument gives possibility to check algorithm performance using simulated input signal.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.