Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  phase sensitive detector
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote High sensitive wiretap detector: design and modeling
EN
This article presents a novel method and improve system for monitoring of unauthorized connections on the subscriber’s local telephone loop. In operation the detector displays electrical changes in impedance characteristics on the subscriber’s telephone line to detect and alert about connecting of wiretapping equipment anywhere on the local loop.
PL
W artukule przedstawiono nową metdę udoskonalenia systemu monitoringu nieautoryzowanych podłączeń do abonenckiej pętli telefonicznej. Podczas pracy detektor rejestruje zmianę elektryczne w charakterystykach impedancji na abonenckiej linii telefonicznej w celu detekcji i alarmowania o podłączeniu podsłuchu w dowolnym miejscu na pentli aboneckiej.
PL
W artykule przedstawiono prototyp analizatora impedancji, w którym zastosowano dwa mikrosystemy AD5933 do wydzielania składowych ortogonalnych sygnałów pomiarowych w zakresie częstotliwości od 0,01 Hz do 1 kHz i detektory fazoczułe dla częstotliwości z przedziału 1 kHz - 100 kHz. Przyjęte rozwiązanie pozwoliło wyeliminować błędy pomiaru argumentu impedancji wprowadzane przez AD5933 w górnym zakresie częstotliwości. Uzyskany błąd względny pomiaru modułu impedancji mieści się w przedziale š1%, a bezwzględny argumentu š1° w całym zakresie częstotliwości.
EN
The paper presents a prototype of an impedance analyzer in which two AD5933 microsystems (Fig. 1) for determination of measurement signal orthogonal parts in the frequency range from 0,01 Hz up to 1 kHz and phase-sensitive detectors for the frequency range 1 kHz ? 100 kHz (Fig. 2) are employed. The phase-sensitive detectors (Fig. 3) were realized using operational amplifiers (AD8065) whose gain was changed from -k to +k and vice-versa, depending on the state (shorted or open) of switches (ADG451) driven by the reference signal. Separate generators AD9833 were used for generation of the excitation signal of the measured impedance and the reference signal. The generators were synchronized by means of the common signal used also by the phase-sensitive detectors. The assumed solution allowed eliminating the impedance argument errors caused by AD5933 in the high frequency range (Fig. 5), while simultaneously minimizing the time required for impedance spectroscopy of the object under test. The relative error of the impedance modulus measurement is in the range of š1%, and the absolute error of the impedance argument is in the range of š1° (Fig. 4).
PL
W artykule przedstawiono zasadę działania oraz konstrukcję wzmacniacza fazoczułego typu lock-in mogącego pracować w trybie dwukanałowym bądź w trybie woltomierza wektorowego. Zaprezentowano zastosowanie opisywanego wzmacniacza w technice mikroskopii bliskich oddziaływań, gdzie obserwacja amplitudy oraz przesunięcia fazowego odpowiedzi sondy ma istotne znaczenie w wysokorozdzielczych badaniach lokalnych właściwości powierzchni preparatu.
EN
In this article design of the two-channel lock-in amplifier is presented. The presented device has implemented four DDS generators and two phase-sensitive detectors. Lock-in amplifier is controlled from PC computer via RS232 interface. This lock-in amplifier is applied in scanning probe microscopy techniques where amplitude and phase resolving is important in obtaining information about local surface properties.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.