Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  perfobond connectors
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The problem of transition zone of structural steel element connected to concrete is discussed in the following paper. This zone may be located for instance in specific bridge composite girder. In such case the composite beam passes smoothly into concrete beam. Because of several dowels usage in the transition zone, the problem of uneven force distribution were discussed through analogy to bolted and welded connections. The authors present innovative solution of transition zone and discuss the results, with emphasis put on the transition zone structural response in term of bending capacity, failure model and force distribution on the connection length. The article wider the already executed experimental test and presents its newest results.
PL
W artykule przedstawiono zagadnienie kształtowania połączenia elementu stalowego z elementem betonowym w strefie przejściowej belki hybrydowej. Strefa ta może być wykorzystana m.in. w nowatorskich rozwiązaniach zespolonych dźwigarów mostowych, umożliwiając ich swobodne kształtowanie podłużne poprzez płynną zmianę pomiędzy przekrojem zespolonym a betonowym. Przedstawiono różne rozwiązania konstrukcyjne strefy przejściowej oraz poruszono problem nierównomiernego rozdziału sił w połączeniach długich, jako jednego z głównych czynników wpływających na kształtowanie połączenia elementu ze stali konstrukcyjnej z konstrukcją betonową. Prototypowe rozwiązanie strefy przejściowej opisano na podstawie przeprowadzonego badania niszczącego omawiając najnowsze wyniki tego badania oraz analizując model zniszczenia i redystrybucję sił na długości strefy.
EN
The paper presents the author's proposal for calculation of shear stresses (disintegrating) induced by concrete shrinkage at the interface of steel and concrete. The proposal also presents expressions to calculate the fatigue strength of a connection in steel–concrete composite girders. The expressions to calculate fatigue strength are based on the results of experiments performed by the author. Based on the results of analyses it can be stated that the load bearing capacity of a connection with flexible shear connectors is strongly affected by a concrete slab adhesion to a steel girder. This effect depends on the stiffness ratio of the girder to concrete deck (coefficient δ), concrete strength and diameter of shear studs d, as well as the value of shrinkage strain of concrete. Fatigue strength of a connection with strip connectors is affected by the geometry of the composite girder and its components, concrete strength and concrete shrinkage strain. At low values of δ, low concrete grades and large diameters of shear connectors or holes, the fatigue strength of the composite connection is likely to be exhausted.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.